![GridConnect NetDirect User Manual Download Page 25](http://html.mh-extra.com/html/gridconnect/netdirect/netdirect_user-manual_2264804025.webp)
Host List Configuration
The NetDirect scrolls through the host list until it connects to a device listed in the host list table.
After a successful connection, the unit stops trying to connect to any others. If this connection
fails, the unit continues to scroll through the table until the next successful connection.
The host list supports a minimum of 1 and a maximum of 12 entries. Each entry contains an IP
address and a port number.
Note: The host list is disabled for Manual and Modem Mode. The unit does not accept a
data connection from a remote device when the hostlist option is enabled.
To configure the host list:
1. On the main menu, click
Hostlist
.
Figure 5-5
Hostlist Settings
2. Enter or modify the following fields:
Retry Settings
Retry Counter
Enter the value for the number of times the NetDirect should attempt to retry
connecting to the host list. The default setting is
3
.
Retry Timeout
Enter the duration (in milliseconds) the NetDirect should abandon
attempting a connection to the host list. The default setting is
250
.
Host Information
Host Address
Enter or modify the host’s IP address.
Port
Enter the target port number.
3. When you are finished, click the
OK
button.
4. On the main menu, click
Apply Settings
.
Summary of Contents for NetDirect