Page 9
AVFM 5.0 Area-Velocity Flow Meter
MAIN DISPLAY
The main display shows the units selected from the
Units/Mode
menu, Flow or
Velocity rate being measured, TOTALIZER and RELAY states. The AVFM 5.0
will start-up with this display.
MESSAGE ICON
Press
from the main display to view temperature measurement, status of the
data logger and error/warning messages provided by the instrument. The
Message Icon will appear on the main display if error messages are being
generated by the instrument. Press
to return to the main display.
STATUS
Press
from the MAIN display to view instrument status.
Velocity
Will be displayed in
ft/sec
or
m/sec
.
Level
Is displayed in the selected units.
Tot
Displays the current totalizer reading.
Signal Cutoff
Adjust the setting in percent to suppress flow readings
at zero flow when fluid swirling or pipe vibration may
cause the instrument to continue reading. Example:
Signal Cutoff
at
5%
will force the display and
outputs to zero when signal strength drops below 5%.
Signal Strength
Displays percentage of signal being received by the
ultrasonic sensor.
EC
Displays level measurement Echo Confidence
Relays 1 2 3 4 5 6
Energized relays will display with reversed font eg:
Summary of Contents for AVFM 5.0
Page 2: ...Note This page has been left blank intentionally ...
Page 5: ...Page 5 AVFM 5 0 Area Velocity Flow Meter CONNECTIONS ...
Page 7: ...Page 7 AVFM 5 0 Area Velocity Flow Meter CALIBRATION MENU ...
Page 8: ...Page 8 AVFM 5 0 Area Velocity Flow Meter ICONS ...
Page 20: ...Page 20 AVFM 5 0 Area Velocity Flow Meter ...
Page 29: ...Page 29 AVFM 5 0 Area Velocity Flow Meter AREA VELOCITY FLOW DATA SHEET ...
Page 34: ...Page 34 AVFM 5 0 Area Velocity Flow Meter SS PIPE MOUNTING BAND OPTION VSJ ...
Page 36: ...Page 36 AVFM 5 0 Area Velocity Flow Meter ...
Page 44: ...Page 44 AVFM 5 0 Area Velocity Flow Meter Dual Non Contacting Sensor Configuration ...
Page 45: ...Page 45 AVFM 5 0 Area Velocity Flow Meter CONNECTIONS Dual Sensor Configuration ...