Page 19
AVFM 5.0 Area-Velocity Flow Meter
INSTALLATION - SENSOR LOCATION
1. Choose a sensor mounting location where silt or deposits are least likely to accumulate.
2. For best results flow should be evenly distributed across the channel and relatively free of turbulence.
(The AVFM 5.0 is very effective at averaging level and velocity readings in turbulent conditions, but
best accuracy and response time is achieved with evenly distributed flow.)
3. Avoid vertical drops, obstructions or elbows immediately up and downstream from the sensor. Locate
the QZ02L sensor at least 10 times maximum Head (level) and 10 times the channel width from these
flow disturbances.
4. The QZ02L submerged level-velocity sensor requires a minimum water level of 1 in. (25.4 mm).
QZ02L VELOCITY-LEVEL SENSOR MOUNTING
Mount the QZ02L sensor with the
stainless steel bracket and hardware
supplied. Ensure that the sensor is
parallel to the water surface (check with
a level). Mount with the tapered end of
the sensor pointing upstream and the
sensor cable pointing downstream.
Clip or tie wrap the sensor cable securely
to the pipe or channel wall.
Note: The mounting bracket is designed
to release the sensor if weeds or rags are
caught by the sensor.
Summary of Contents for AVFM 5.0
Page 2: ...Note This page has been left blank intentionally ...
Page 5: ...Page 5 AVFM 5 0 Area Velocity Flow Meter CONNECTIONS ...
Page 7: ...Page 7 AVFM 5 0 Area Velocity Flow Meter CALIBRATION MENU ...
Page 8: ...Page 8 AVFM 5 0 Area Velocity Flow Meter ICONS ...
Page 20: ...Page 20 AVFM 5 0 Area Velocity Flow Meter ...
Page 29: ...Page 29 AVFM 5 0 Area Velocity Flow Meter AREA VELOCITY FLOW DATA SHEET ...
Page 34: ...Page 34 AVFM 5 0 Area Velocity Flow Meter SS PIPE MOUNTING BAND OPTION VSJ ...
Page 36: ...Page 36 AVFM 5 0 Area Velocity Flow Meter ...
Page 44: ...Page 44 AVFM 5 0 Area Velocity Flow Meter Dual Non Contacting Sensor Configuration ...
Page 45: ...Page 45 AVFM 5 0 Area Velocity Flow Meter CONNECTIONS Dual Sensor Configuration ...
Page 51: ......