Page 22
AVFM 5.0 Area-Velocity Flow Meter
OPTIONAL PZ15-LP LEVEL SENSOR MOUNTING
Mount the PZ15-LP non-contacting ultrasonic level sensor in an unobstructed position at least 8” (203.2
mm) above the high water level. Install the stainless steel mounting bracket in a horizontal position
(check with a level) and then insert the PZ15-LP sensor.