GIR1002 FR / GIA1000 FR       Connecting and Operating Manual         Version: 4.03-3       page: 1

Connecting and Operating Manual

GIR1002 FR

GIA1000 FR

Version: 4.03

This connecting and operating manual may be subject to technical alternations.

ON/SP

SET

min.

OFF/Hy.

1

2

max.

G IR/G IA

ALARM

Scale

Analog

CAL

SET

1

2

3

4

In accordance with

EN50081-1 and EN50082-2

for unrestricted use in

housing and industrial areas

Summary of Contents for GIA1000 FR

Page 1: ...rating Manual GIR1002 FR GIA1000 FR Version 4 03 This connecting and operating manual may be subject to technical alternations ON SP SET min OFF Hy 1 2 max GIR GIA ALARM Scale Analog CAL SET 1 2 3 4 I...

Page 2: ...ge 7 Max value reset page 7 Display of min value page 7 Min value reset page 7 Display setting of making point switching point for switching output 1 or 2 page 7 Display setting of breaking point hyst...

Page 3: ...l supply the GIR1002 FR factory tested and completely calibrated Before you can actually use it make sure to configurate your GIR1002 FR for your special application Please also refer to the chapter C...

Page 4: ...connected to a suitable RC element for example RC220 Electric connection and commissioning of the device must be carried out by trained and skilled personnel Wrong connection may lead to the destructi...

Page 5: ...min selectable Interface RS485 Power supply 230VAC or as specified on device housing Power consumption 5W 230VAC 3W 24VDC 1 5W 12VDC Relay switching power 10A 250V AC ohmic load use RC element when sw...

Page 6: ...setting of making point button 1 4 1 2 3 7 display setting of switching point button 1 4 4 5 6 8 display setting of breaking point button 1 4 1 2 3 7 display setting of hysteresis button 1 4 4 5 6 8 S...

Page 7: ...in case of alarm LED min LEDflashing Min value reset To be called up by pressing button 3 for approx 4s Display please refer to display of min value Display setting of makingpoint switching point for...

Page 8: ...briefly no more than 1 s When pressing these buttons for a longer time over 1 s the values will start scrolling upwards respectively downwards After scrolling of approx 150 digits the scrolling speed...

Page 9: ...int to the left or button 3 shift decimal point to the right to set desired decimal point position acknowledge position by pressing button 4 If decimal point is positioned to the right of the lowest d...

Page 10: ...urrent of 20mA LED max will start flashing acknowledge by pressing button 4 8 LEDs Analog min and LED CAL are illuminated The display will show the measuring value stored in the GIR1002 FR for which a...

Page 11: ...rmissibe range This fault code indicates that the min display value of 1999 digits has fallen below Remedies FE 4 will be reset as soon as the values on the display are back within their permissible r...

Page 12: ...This method as well as the fact that the interface operates in the half duplex mode ensure that up to 16 devices can be called via only one 2 wire line Interface configuration Type RS485 Transfer mode...

Page 13: ...s specifying the parameter and or value to be processed For assignments please refer to table 1 of chapter functional code ASCII Code 2FH Indicates the end of a data transfer process Each data transfe...

Page 14: ...g point Switching point 0 9 30H 39H 1 Switching output 2 Breaking point Hysteresis 0 A 30H 41H 1 Max alarm limit 0 B 30H 42H 1 Min alarm limit 0 C 30H 43H 1 Input signal 1 5 31H 35H 3 Position of deci...

Page 15: ...l The assignment is as follows 0 2Vss 1 300mVss 2 30mVss 3 TTL Data format 4 This format is used to call up and or program the position of the decimal point The assignment is as follows 0 no decimal p...