1. Safety regulations

This device was designed and tested considering the Safety regulations for electronic measuring devices.
Faultless operation and reliability in operation of the measuring device can only be assured if the General
Safety Measures and the devices specific safety regulation mentioned in this users manual are considered.
1. Faultless operation and reliability in operation of the measuring device can only be assured if the device

is used within the climatic conditions specified in the chapter “Specifications“.

2. Always disconnect the device from its supply before opening it. Take care that nobody can touch any of

the unit‘s contacts after installing the device.

3. Standard regulations for operation and safety for electrical, light and heavy current equipment have to be

observed, with particular attention paid to the national safety regulations (e.g. VDE 0100).

4. When connecting the device to other devices (e.g. the PC) the interconnection has to be designed most

thoroughly, as internal connections in third-party devices (e.g. connection of ground with protective earth)
may lead to undesired voltage potentials.

5. The device must be switched off and must be marked against using again, in case of obvious malfunc-

tions of the device which are e.g.:
- visible damage
- no prescripted working of the device
- storing the device under inappropriate conditions for longer time
When not sure, the device should be sent to the manufacturer for repairing or servicing.

Attention:

 When running electric devices, parts of them will always be electrically live.

Unless the warnings are observed serious personal injuries or damage to property
may result. Skilled personnel only should be allowed to work with this device. For trou-
ble-free and safe operation of the device please ensure professional transport, stor-
age, installation and connection as well as proper operation and maintenance.

Skilled personnel

are persons familiar with installation, connection, commissioning and operation of the product and have pro-
fessional qualification relating to their job.

For example:

 • Training or instruction resp. qualifications to switch on or off, isolate, ground and mark electric circuits and

devices or systems.

 • Training or instruction according to the state.

 • First-aid training.

 

ATTENTION:

Do NOT use this product as safety or emergency stopping device, or in any other applica-
tion where failure of the product could result in personal injury or material damage.

Failure to comply with these instructions could result in death or serious injury and mate-
rial damage.

Summary of Contents for EB 3000

Page 1: ...B 3000 page 1 of 19 Manual for connection and operation of EASYBus control display and supervisory device EB 3000 as of Version 1 7 GREISINGER electronic GmbH D 93128 Regenstauf Hans Sachs Stra e 26 T...

Page 2: ...sioning of the EB3000 8 6 OPERATION OF THE EB3000 8 6 1 How to display the current measurement values 8 6 2 How to display or reset the min max values 9 6 3 Setting of switching points 9 6 4 Setting o...

Page 3: ...evice must be switched off and must be marked against using again in case of obvious malfunc tions of the device which are e g visible damage no prescripted working of the device storing the device un...

Page 4: ...terfaces EASYBUS output connection for the EASYBUS sensor modules EASYBUS input permits via level converter e g EBW1 EBW64 communication with a superior computer master The EB3000 cyclically enquires...

Page 5: ...setting setting mode selection 3 Key 4 interruption recognition of the last setting acknowledgement of an error message 4 Main display indication of current measurement value resp min max value 5 Aux...

Page 6: ...1 Switching output 3 normally open 10 Switching output 4 normally open 9 Alarm output normally closed 8 Alarm output normally open 7 Alarm output common connector 6 Supply voltage 230VAC 5 Supply volt...

Page 7: ...y 2 EASYBUS standard loads EBN 2 EASYBUS standard loads EBHT EBT EBH 1 5 EASYBUS standard loads GIA20EB GIR2002 1 EASYBUS standard load W hen connecting the modules keep in mind that the sum of all bu...

Page 8: ...calculation functions choose register tab virtual channels for programming the desired func tion for virtual channel 1 or 2 For details see chapter 9 EB3000 Configuration 6 Operation of the EB3000 Hin...

Page 9: ...off point In the auxiliary display the text of the allocated channel appears Use key 1 to select the adjustable switching parameter Push key 2 or 3 In the main display the currently adjusted switching...

Page 10: ...the main display AL Lo appears again With key 4 you can cancel the setting at any time the made modification is resetted and in the main display AL Lo appears again Press key 1 again and the adjusted...

Page 11: ...ossible causes Incorrect scale Counter overflow Remedies The error message will be reset if the display value is below 9999 Reset the counter When happening frequently check the scale setting maybe it...

Page 12: ...ion error CRC Code wrong Indicates that the enquiry of an attached EASYBUS measurement channel has generated an CRC error Possible causes multiple attached EASYBUS measurement channels have the same a...

Page 13: ...rformed incorrect configuration bus is blocked in fact of a master requiry Remedies remove alarm by pushing key 4 or by using EASYBUS Configurator software perform new configuration of the EB3000 The...

Page 14: ...lly adjustable Alarm output 1 relay output changeover Switching capacity 230VAC 5A ohmic load Alarm functions Collective alarm for all sensors alarm settings for all sensors changeable Displays Main d...

Page 15: ...d system configuration In this case the following described EB3000 configuration must be performed again Afterwards you reached the EB3000 configuration window displayed on next page with all availabl...

Page 16: ...19 10 2 EB3000 Configuration By double click on the EB3000 symbol on the device overview a configuration window for the EB3000 opens Now 5 register tabs are available monitoring display control outpu...

Page 17: ...not too low to avoid error messages of the measurement system 2 Predetermination of the display of individual channels auxiliary display channel description for the respective channel shown in the aux...

Page 18: ...e modified via EB3000 device keys switch off point delay minimum switching delay in seconds after a turn off until output turns on again function switching function of the outputs in case of error see...

Page 19: ...l functions for download are available After download copy transferred datafiles easily into directory EB3CV inside of the configurator installation directory By the next start of register tab virtual...

Reviews: