E35.0.01.6C-03                     Manual for connection and operation of the EB 3000                          page 9 of 19

6.2. How to display or reset the min-/max-values

You can call and display the min-/max-values of the 

EASY

BUS

-measurement channels by using EB3000.

Hint: 

The EB3000 can only readout the respective min-/max-values. The values stored in the
respective sensor modules will not be saved in the EB3000.

If a min-/max-value is shown, LED „min“ resp. „max“ illuminates.

Key-operating:
- Key 

1

 shortly pushed:

display changes between actual value, min-value and max-value

- Key 

1

 pushed >1 sec.:

if cyclic display = off:

clear

 

min-/max-values of the displayed measurement 

channel.

if cyclic display = on:

clear min-/max-values of all activated measurement 
channels.

After 30 sec. the display of the min-/max-values automatically finish and the actual value is shown again.

6.3. Setting of switching points

The switching-on-points and switching-off-points of the outputs can be called and changed via the input
keys. Therefore only switching outputs with an allocated channel are shown. 

If no channel was allocated to

the switching output a call of function ‚setting of switching points‘ is not possible.

Please note:

 If no key is pushed by inputing a value longer than 10 sec., it will be changed to the parametric

display  again, after another 30 sec. the switching point setting of the device will be stopped. Not stored modifi-
cations will not be saved and are lost!

Hint: A call is only possible, if the display of the device shows the actual value

-

 Push 

key 

1

 and 

2

 for >1 second

In the main display “

X.on

“ resp. “

X.off 

“ appears.

  (X = number of the switching output, on =  switching-on-point, off = switching-off-point).
In the auxiliary display the text of the allocated channel appears.

-

 Use 

key 

to select the adjustable switching parameter.

-

 Push 

key 

2

 or 

3

.

In the main display the currently adjusted switching point appears.

-

 Use 

key 

2

 and 

3

 to set the new desired value, whereas this output shall be switched on or off.

-

 Use 

key 

1

 to acknowledge the adjusted switching point. The new switching point will be saved and in

the main display “

X.on

“ resp. “

X.off 

“ appears again.

With key 

4

 you can cancel the setting at any time, the made modification is resetted and in the main

display „

X.on

“ resp. “

X.off 

“ appears again.

-

 Use 

key 

1

 to select the next adjustable switching parameter and set as described.

With key 

4

 you can cancel/finish the setting of the switching point at any time, and the actual measure-

ment value is displayed again.

Hint: The setting of the switching points can also be performed comfortable for each channel with software
„EASYBUS-Configurator“ (see chapter 8 – appendix).

6.4. Setting of alarm limits

If the connected 

EASY

BUS

-measurement channel

 supports an alarm function the min-/max alarm limits and

the alarm delay can be called and changed via the input keys.

Please note:

 If no key is pushed by inputing a value longer than 10 sec., it will be changed to the parametric

display  again, after another 30 sec. the switching point setting of the device will be stopped. Not stored modifi-
cations will not be saved and are lost!

Hint: 

Here you can call and change the alarm limits of the 

EASY

BUS

-measurement channel.

The alarm limits stored in the 

EASY

BUS

-sensor modules will not be saved in the EB3000.

The settings of the alarm limits will only be carried out for the currently displayed measurement channel.

TIPP: For setting the alarm limits we suggested to switch-off the cyclic display for a „manually“ se-

lection of the setting channel.

Summary of Contents for EB 3000

Page 1: ...B 3000 page 1 of 19 Manual for connection and operation of EASYBus control display and supervisory device EB 3000 as of Version 1 7 GREISINGER electronic GmbH D 93128 Regenstauf Hans Sachs Stra e 26 T...

Page 2: ...sioning of the EB3000 8 6 OPERATION OF THE EB3000 8 6 1 How to display the current measurement values 8 6 2 How to display or reset the min max values 9 6 3 Setting of switching points 9 6 4 Setting o...

Page 3: ...evice must be switched off and must be marked against using again in case of obvious malfunc tions of the device which are e g visible damage no prescripted working of the device storing the device un...

Page 4: ...terfaces EASYBUS output connection for the EASYBUS sensor modules EASYBUS input permits via level converter e g EBW1 EBW64 communication with a superior computer master The EB3000 cyclically enquires...

Page 5: ...setting setting mode selection 3 Key 4 interruption recognition of the last setting acknowledgement of an error message 4 Main display indication of current measurement value resp min max value 5 Aux...

Page 6: ...1 Switching output 3 normally open 10 Switching output 4 normally open 9 Alarm output normally closed 8 Alarm output normally open 7 Alarm output common connector 6 Supply voltage 230VAC 5 Supply volt...

Page 7: ...y 2 EASYBUS standard loads EBN 2 EASYBUS standard loads EBHT EBT EBH 1 5 EASYBUS standard loads GIA20EB GIR2002 1 EASYBUS standard load W hen connecting the modules keep in mind that the sum of all bu...

Page 8: ...calculation functions choose register tab virtual channels for programming the desired func tion for virtual channel 1 or 2 For details see chapter 9 EB3000 Configuration 6 Operation of the EB3000 Hin...

Page 9: ...off point In the auxiliary display the text of the allocated channel appears Use key 1 to select the adjustable switching parameter Push key 2 or 3 In the main display the currently adjusted switching...

Page 10: ...the main display AL Lo appears again With key 4 you can cancel the setting at any time the made modification is resetted and in the main display AL Lo appears again Press key 1 again and the adjusted...

Page 11: ...ossible causes Incorrect scale Counter overflow Remedies The error message will be reset if the display value is below 9999 Reset the counter When happening frequently check the scale setting maybe it...

Page 12: ...ion error CRC Code wrong Indicates that the enquiry of an attached EASYBUS measurement channel has generated an CRC error Possible causes multiple attached EASYBUS measurement channels have the same a...

Page 13: ...rformed incorrect configuration bus is blocked in fact of a master requiry Remedies remove alarm by pushing key 4 or by using EASYBUS Configurator software perform new configuration of the EB3000 The...

Page 14: ...lly adjustable Alarm output 1 relay output changeover Switching capacity 230VAC 5A ohmic load Alarm functions Collective alarm for all sensors alarm settings for all sensors changeable Displays Main d...

Page 15: ...d system configuration In this case the following described EB3000 configuration must be performed again Afterwards you reached the EB3000 configuration window displayed on next page with all availabl...

Page 16: ...19 10 2 EB3000 Configuration By double click on the EB3000 symbol on the device overview a configuration window for the EB3000 opens Now 5 register tabs are available monitoring display control outpu...

Page 17: ...not too low to avoid error messages of the measurement system 2 Predetermination of the display of individual channels auxiliary display channel description for the respective channel shown in the aux...

Page 18: ...e modified via EB3000 device keys switch off point delay minimum switching delay in seconds after a turn off until output turns on again function switching function of the outputs in case of error see...

Page 19: ...l functions for download are available After download copy transferred datafiles easily into directory EB3CV inside of the configurator installation directory By the next start of register tab virtual...

Reviews: