Troubleshooting
Problem
Cause
Solution
Blade is not moving
Too much oilflow
Check the oilflow
Hoses not connected correctly
Switch the hoses
The pump is off
Activate the pump
The Blade locks after a
stroke
Hoses not connected correctly
Switch the hoses
Low pump pressure
Consult a specialist shop
Twigs have frayed ends
The knives are worn
Consult a specialist shop
Surface-grinding of knife and
bushings. Consult a specialist
shop
Knife bolts are loose
Tighten the bolts and grease
well
Too high forward speed
Adjust the speed
Blade runs too fast
Too much oilflow
Check the oilflow
Too much oilflow
Mount the flow divider
Overheating
Incorrect tool speed
Test the speed of the tool
Low oil level in tank
Check the oil level
Wrong type of oil
Empty the tank, add correct type
of oil
Clotting near cutting blades
Remove branch, debris etc.
Noise Measurement
The following noise measurement was performed on the machine under normal
operating conditions at GreenTec A/S using an Elma 1350B decibel meter, ICE 651
type II.
The equivalent A-weighted continuous sound pressure level is less than
85 dB (A).
The above measurements were taken 1 meter from the critical noise emitters of the
equipment and 1.5 meters above the ground.