The temperature control function starts by pressing the key. The key is lit. Pressing the button
again will end the function and the led will go out.
SYSTEM ON OFF KEY
It is red when the unit is off, and it lights up when it is on. It is enough to press 1 time to turn
on the device. To close it, press and hold for 3 seconds. No control will operate when in the off
position.
TEMPERATURE KEY
This display is at the same level as the heating set keys. Normally the set temperature shows.
When the temperature or humidity setting key is pressed for 2 seconds, the instantaneous
temperature value is displayed on the screen. With the LED on the side, it is also checked
whether the heating is done or not. If the LED is lit, the unit is not at the set value and is
heating. The set value is reached when the led turns off.
HUMINITY KEY
This indicator is at the same level as the humidity set keys. Normally the set shows the
humidity value. If the temperature or humidity setting key is pressed for 2 seconds, the instant
humidity value is displayed on the screen. With the LED on the side, it is also checked whether
the humidification is done or not. If the LED is lit, the unit is not at the desired setpoint and is
humidifying. The set value is reached when the led turns off.
WORKING OF THE PANEL
When the device is first powered up, the device is switched off. All indicators and LEDs are off,
only the red LEDs are off. When the ON / OFF button is pressed, the device switches on but no
control is switched on.
It is possible to operate by pressing the Lamp and Fan keys. These functions are deactivated
when the key is pressed repeatedly. Heating and humidification controls after the fan is switched
on; can be turned on and off by pressing the control keys. The appliance will humidify and heat
up to the set value. When the desired value is reached, the humidity and heat outputs will be
deactivated. Once these values are below the set values, the outputs belonging to these controls
enter the circuit. If there is no humidification or heating, the leds are shown.
CODES OF FAULTS
E1 FAILURE:
This is the only fault code found on the device. This error message is displayed
if the sensor is broken or the connection of the sensor and the brewing controller breaks. The
error remains on the screen until it is cleared. The device checks are turned off as long as the
error persists.
PARAMETERS
While the device is off, press and hold both of the humidity setting arrow keys for 3 sec. Buttons
are not released until Pr appears on the screen. The display will show the temperature control
process status in the upper display group and the lower display will show the status of the
humidification process.
1 is active, 0 is inactive.
The arrow keys next to the display will be used to change the processing format.
At the end of the process the fan button will be used for output. The process is not displayed
on the screen and the relay output will not work.