background image

installation and operation manual

 

GreenLife 

 

hybrid manager

 

 
 
 
 
 
 
Technical support via: 

 

Stand: 03.05.19 

phone: +49 (0) 385 7733 775 

 

Subject to technical changes 

E-Mail: 

[email protected]

 

 

We shall not be liable for printing errors 

www.greenlife.de

 

 

installation and operation manual 

 
hybrid manager 
 
Dear Customer, 

Congratulations on buying this GreenLife product and thank you for the trust you 
have placed in us. 

Please check this product for any damage caused in transit as soon as you receive it. 
The forwarding agent is liable for any damage in transit and not the manufacturer or 
supplier. If you accept the goods without reporting any damage in transit, any claims 
cannot be asserted. Should the packaging be damaged, you must unpack the goods 
immediately in the presence of the deliverer in order to ascertain any damage that 
will have to be reported to the forwarding agent in writing. The goods must remain 
with the purchaser until the issue of the damage caused in transit has been clarified. 

Before installing this product you have to read these instructions carefully and in full 
and comply with all the safety instructions. 

Please keep these instructions in a safe place for future consultation. If you have any 
questions or comments, you can contact us via  

[email protected]

 

Yours sincerely, 

Your GreenLife Team  

 

 

Summary of Contents for hybrid manager

Page 1: ...Einbau und Betriebsanleitung Hybridmanager Trennstation www greenlife de...

Page 2: ...rachtf hrer Nach Warenannahme ohne Transportsch den anzuzeigen k nnen diese nicht mehr geltend gemacht werden Sollte die Verpackung besch digt sein ist sofort im Beisein des Anlieferers auszupacken um...

Page 3: ...ife info 2 F r Druckfehler wird keine Haftung bernommen www greenlife de Inhaltsverzeichnis Im Lieferumfang enthalten 3 Einsatzgebiet 4 Hinweise und Erl uterungen 4 Aufstellung der Beh lter 5 Anschlus...

Page 4: ...ter f r Kugelhahn zur Entleerung Siphon als Not berlauf Technische Daten Pumpe GUP 46 max F rderh he 44 m max F rdermenge 75 l min max Leistung 0 85 kW P1 max Arbeitsdruck 4 4 bar Spannung 230 V Frequ...

Page 5: ...ltnisse hat oder zu lang ist F r hohe Betriebssicherheit sorgen die robusten Schwimmerschalter im Hybridbeh lter sowie die integrierte Trinkwasser Nachspeisung Hinweise und Erl uterungen Bei l ngerem...

Page 6: ...utz vor Verwechslung durch Kinder sind Zapfstellen mit Kindersicherung Bei der Wahl der Einbaustelle ist darauf zu achten dass die Tanks jederzeit zug nglich und die Entleerung jederzeit m glich ist D...

Page 7: ...Entkalkungsanlage eingebaut werden Hinweis zur Installation Ventil bei der ersten Installation der Trinkwasserleitung nicht verdrehen Ventil absolut spannungsfrei anschlie en Ventil muss senkrecht im...

Page 8: ...bernommen www greenlife de Entleerung Anschluss AG 1 Anschl sse GHM 0 14 Anschl sse GHM 0 35 and 0 50 Pumpe GUP 46 Zulauf AG 1 aus der Zisterne Siphon Not berlauf DN 110 optionaler Anschluss Trinkwass...

Page 9: ...mmen www greenlife de Anschl sse GHM 1 25 Anschl sse GHM 4 0 Pump GUP 46 Zulauf AG 1 aus der Zisterne optionaler Anschluss Trinkwasser Anschluss AG Druckerh hung AG 1 Servicewasser unten Siphon Not be...

Page 10: ...ung zu verwenden Den maximalen Abstand zur Pumpe entnehmen Sie der Leistungskurve der Pumpe Druckleitung ist in einem St ck von der Pumpe bis zum Hybridbeh lter zu verlegen Schlie en Sie die schwimmen...

Page 11: ...19 Telefon 49 0 385 7733 775 Technische nderungen vorbehalten E Mail service greenlife info 10 F r Druckfehler wird keine Haftung bernommen www greenlife de GHM 1 25 bis 4 0 Doppelstecker Druckerh hun...

Page 12: ...n Mediums 40 C max temperature of pumped liquid Pumpenlaufr der Material Edelstahl stainless steel rotor discs of the pump material Pumpenschaft Material Edelstahl stainless steel shaft of the pump ma...

Page 13: ...installation and operation manual hybrid manager www greenlife de...

Page 14: ...he manufacturer or supplier If you accept the goods without reporting any damage in transit any claims cannot be asserted Should the packaging be damaged you must unpack the goods immediately in the p...

Page 15: ...Fehler Textmarke nicht definiert field of application Fehler Textmarke nicht definiert notes and applications Fehler Textmarke nicht definiert positioning of the tanks Fehler Textmarke nicht definier...

Page 16: ...lve as drain siphon as emergency overflow technical details pump GUP 46 max height 44 m max flow rate 75 l min max power consumption 0 85 kW P1 max operating pressure 4 4 bar voltage 230 V frequency 5...

Page 17: ...adverse geotechnical conditions or is too long High operational reliability is ensured by solid floating switches in the hybrid tank and integrated mains water back up notes and explanations If the s...

Page 18: ...n against confusion by children can be taps with child safety When choosing the place of installation make sure that the tanks are accessible at all times and that they can be emptied at any time The...

Page 19: ...suitable decalcification unit has to be installed notes for installation do not turn the valve during the first installation of the mains water line connect the valve completely de energized valve ha...

Page 20: ...thread 1 connections GHM 0 14 connections GHM 0 35 and 0 50 pump GUP 46 inflow male thread 1 from the tank siphon emergency overflow DN 110 optional connection mains water connection male thread boost...

Page 21: ...0 pump GUP 46 inflow male thread 1 from the tank optional connection mains water connection male thread booster station male thread 1 service water on the bottom siphon emergency overflow DN 110 drai...

Page 22: ...sure line please check the performace chart of the pump for the maximum distance the pressure line has to be installed in one piece from the feeder pump into the hybrid tank connect the floating sucti...

Page 23: ...5 19 phone 49 0 385 7733 775 Subject to technical changes E Mail service greenlife info 10 We shall not be liable for printing errors www greenlife de GHM 1 25 and 4 0 double plug booster station not...

Page 24: ...ums 40 C max temperature of pumped liquid Pumpenlaufr der Material Edelstahl stainless steel rotor discs of the pump material Pumpenschaft Material Edelstahl stainless steel shaft of the pump material...

Reviews: