p.
25/48
After the burner’s software has been loaded into the control module (which actually takes
several seconds), the display indicates a question:
should the burner be activated
(
Activate
?
)
:
Figure 5.3.
Menu item shown on the display at start-up procedure of the automatic pellet
burner of series “GP IV”, indicating reminding question.
In order to start the burner, press the button “S”, as shown on the figure above.
After the burner has been activated, the display indicates the following message.
Figure 5.4.
The
display indicates information for the current operating mode of the control
module –
in the case the control module performs functional check procedure of the air
supply fan
.
COMMENTS :
●
„TEST – BLOWING “ –
indicates
the
operating mode – in the example the control
module performs initial air fan blowing, which is dedicated to blow away any residues
on the burner’s grate;
●
„ 32
о
”
–
indicates
(
shown on the display, in the lower right corner, above the “S”
button
) the temperature of the circulating water in the heat exchanger of a hot water
boiler, in degrees Celsius. The circulating water temperature is indicates in case the
control module is equipped with appropriate temperature sensor and the control
module has been adjusted to operate with such sensor;
S
_
+
ESC
Activate ?
ENTER
S
_
+
ESC
TEST - BLOWING
32
o
FC: 0%