S
ECTION D: DIAGRAM OF ELECTRIC PLANT. NO-STRESS UNIT
BC 260 User’s Handbook
Page 28
ELETTROVALVOLA
SENSORE
nero
blu
blu
blu
marrone
marrone
-
+
12v
+ -
ALLA
BA
TTERIA
SOLENOID VALVE
SENSOR
BATTERY
black
blue
blue
blue
brown
brown
T
O
THE
BA
TTER
Y
NO-STRESS DEVICE MOD. HC960
FUNCTIONS OF DEVICE:
NB: Push buttons with arrows are utilized only to set and program a
device during the installation.
Machine still but in tension:
- HC960 visualizes total work hours
- Pressing the button “S” HC960 visualizes daily work hours
- Pressing the button “S” for more than 10 seconds HC960
sets to zero daily hourcounter.
Setting of device:
Machine in working:
-
- When machine is in work it is possible to see daily work hours pressing for 3
seconds the button “S”
HC960 visualizes a number of turns carried out by rotor plant
- set the machine in regim, be sure that it is unloaded, press the button “S” to
adjust NO-STRESS unit;
THIS OPERATION MUST BE REPEATED EACH TIME YOU START UP
YOUR MACHINE.
Bianco/rosso
White/red