GREE U-Match 5 SERIES UNIT SERVICE MANUAL
51
Filtering Board:
No.
Printing
Interface
No.
Printing
Interface
1
N-OUT1
Power output neutral wire terminal (for
U-MATCH)
6
E1
Filtering board grounding hole (reserved)
2
N-OUT
Power output neutral wire terminal (reserved
for other models)
7
N
Power input neutral wire t erminal
3
L-OUT
Power output live wire terminal (reserved for
other models)
8
AC-L
Power input live wire terminal
4
L-OUT1
Power output live wire terminal (for U-MATCH)
9
DC-BUS
DC busbar terminal
5
E
Filtering board grounding hole
—
—
—
3.2.2 IPM, PFC Testing Method
3.2.2.1Method of Testing IPM Module
(1) Preparation before test: prepare a universal meter and turn to its diode option, and then remove the wires
U, V, W of the compressor after it is powered off for one minute.
(2) Testing Steps
Step 1: put the black probe on the place P and the red one on the wiring terminal U, V, W respectively as
shown in the following figure to measure the voltage between UP, VP and WP.
Step 2: put the red probe on the place N and the black one on the wiring terminal U, V, W respectively as
shown in the following figure to measure the voltage between NU, NV and NW.
5
6
1
2
3
4
7
8
9
Summary of Contents for U-Match 5 Series
Page 31: ...GREE U Match 5 SERIES UNIT SERVICE MANUAL 28 Model GUD100W NhA T...
Page 32: ...GREE U Match 5 SERIES UNIT SERVICE MANUAL 29 Model GUD125W NhA T GUD140W NhA T...
Page 33: ...GREE U Match 5 SERIES UNIT SERVICE MANUAL 30 Model GUD100W NhA X...
Page 34: ...GREE U Match 5 SERIES UNIT SERVICE MANUAL 31 Model GUD125W NhA X GUD140W NhA X...
Page 35: ...GREE U Match 5 SERIES UNIT SERVICE MANUAL 32 Model GUD160W NhA X...
Page 59: ...GREE U Match 5 SERIES UNIT SERVICE MANUAL 56 Troubleshooting...
Page 78: ...GREE U Match 5 SERIES UNIT SERVICE MANUAL 75 Troubleshooting...
Page 224: ...JF00303775...