GREE U-Match 5 SERIES UNIT SERVICE MANUAL
15
Pollution Level
Accumulated
Operating Time
(hour)
Pollution Level
Accumulated
Operating Time
(hour)
Pollution Level
Accumulated
Operating Time
(hour)
11
6000
21
1800
31
200
12
6500
22
2200
32
300
13
7000
23
2600
33
400
14
7500
24
3000
34
500
15
8000
25
3400
35
600
16
8500
26
3800
36
700
17
9000
27
4200
37
800
18
9500
28
4600
38
900
19
10000
29
5000
39
1000
2.3.2 Low-temperature Drying Function
Under dry mode, when the setting temperature is 16
℃
, press “▼” button for twice, the setting temperature
becomes 12
℃
, then the unit enters into low-temperature dry function.
When low-
temperature dry function is turned on, directly press “▲” button or switch the mode can quit the
function.
2.3.3 Child-lock Function
Without error, under ON or OFF status of unit, press “▲” and “▼” buttons simultaneously for 5 seconds can
enter into child-lock function, the liquid crystal screen will display “
”; Press “▲” and “▼” buttons simultaneously
again for 5 seconds can quit the child-lock function.
Under child-lock status, no response for pressing any buttons. The unit will memorize the child-lock status
after power failure and re-energizing the unit.
2.3.4 Memory Function
Under power-
off status, press “MODE” and “▲” bu
tton simultaneously for 5 seconds can turn on or turn off
memory function. When memory function is set, “MEMORY” displays.
If memory function has not been set, when the unit is re-energized after power failure, the unit is power-off
status. If the memory function is set in wired controller, when the wired controller is re-energized after power
failure, it will resume to the operating status before power failure.
2.3.5 Door Control Function
When door control function is selected, the wired controller will work when the room card is inserted and stop
Summary of Contents for U-Match 5 Series
Page 31: ...GREE U Match 5 SERIES UNIT SERVICE MANUAL 28 Model GUD100W NhA T...
Page 32: ...GREE U Match 5 SERIES UNIT SERVICE MANUAL 29 Model GUD125W NhA T GUD140W NhA T...
Page 33: ...GREE U Match 5 SERIES UNIT SERVICE MANUAL 30 Model GUD100W NhA X...
Page 34: ...GREE U Match 5 SERIES UNIT SERVICE MANUAL 31 Model GUD125W NhA X GUD140W NhA X...
Page 35: ...GREE U Match 5 SERIES UNIT SERVICE MANUAL 32 Model GUD160W NhA X...
Page 59: ...GREE U Match 5 SERIES UNIT SERVICE MANUAL 56 Troubleshooting...
Page 78: ...GREE U Match 5 SERIES UNIT SERVICE MANUAL 75 Troubleshooting...
Page 224: ...JF00303775...