GREE
Multi Variable Air Conditioners Indoor Unit
34
Model
GMV-ND07PHS/B
- T(U)
GMV-ND09PHS/
B- T(U)
GMV-ND12PHS/B
-T(U)
GMV-ND15PHS/B
-T(U)
Sound Pressure Level(H/M/L)
dB(A)
35/33/31
35/33/31
36/34/32
40/37/34
Heat Exchanger
Fenestrate plain film -- hydrophilic film
Air Filter
PP
PP
PP
PP
Insulation Material
Foamed polystyrene
Refrigeration Control Device
EXV
EXV
EXV
EXV
Protection Device
Fuse
Fuse
Fuse
Fuse
Model
GMV-ND18PHS/B
-T(U)
GMV-ND22PHS/B
-T(U)
GMV-ND24PHS/B
-T(U)
GMV-ND30PHS/B
-T(U)
Product code
CM810N0810
CM810N0720
CM810N0730
CM810N0780
Cooling Capacity
Btu/h
18000
22000
24000
30000
kW
5.3
6.4
7
8.8
Heating Capacity
Btu/h
20000
24000
27000
34000
kW
5.9
7
7.9
10
Casing Finish
Galvanized Steel plate
Dimensions
(W×D×H)
Outline
mm
1000×700×300
1000×700×300
1000×700×300
1400×700×300
inch
39-3/8×27-9/16
×11-13/16
39-3/8×27-9/16
×11-13/16
39-3/8×27-9/16
×11-13/16
55-1/8×27-9/16
×11-13/16
Packaging
mm
1205×813×360
1205×813×360
1205×813×360
1601×813×365
inch
47-7/16×32
×14-3/16
47-7/16×32
×14-3/16
47-7/16×32
×14-3/16
63-1/16×32
×x14-3/8
Net Weight
lbs.
94
94
94
121
kg
42.6
42.6
42.6
55
Gross Weight
lbs.
108
108
108
137
kg
49
49
49
62
Pipe
Connections
Liquid Side
mm
Φ9.52
Φ9.52
Φ9.52
Φ9.52
inch
Φ3/8
Φ3/8
Φ3/8
Φ3/8
Gas Side
mm
Φ15.9
Φ15.9
Φ15.9
Φ15.9
inch
Φ5/8
Φ5/8
Φ5/8
Φ5/8
Drain Pipe
mm
Φ25
Φ25
Φ25
Φ25
inch
Φ1
Φ1
Φ1
Φ1
Power supply
1-phase 208/230V 60Hz
Fan
Type × Quantity
Centrifugal×2
Centrifugal×2
Centrifugal×2
Centrifugal×3
Driving Mechanism
Direct-driven
Direct-driven
Direct-driven
Direct-driven
Motor Type
BLDC
BLDC
BLDC
BLDC
Motor Power Input
W
/
/
/
/
Motor Running
Current
A
0.7
0.7
0.9
1.2
Airflow
Rate(H/M/L)
CFM
589/471/412
589/471/412
736/618/559
1059/853/736
m
3
/h
1000/800/700
1000/800/700
1250/1050/950
1800/1450/1250
External
Static
Pressure
Default
inchW.G
0.36
0.36
0.36
0.36
Pa
90
90
90
90
Range
inchW.G
0~0.8
0~0.8
0~0.8
0~0.8
Pa
0~200
0~200
0~200
0~200
Sound Pressure Level(H/M/L)
dB(A)
42/38/35
42/38/35
43/39/35
44/41/38
Heat Exchanger
Fenestrate plain film -- hydrophilic film
Air Filter
PP
PP
PP
PP
Insulation Material
Foamed polystyrene
Refrigeration Control Device
EXV
EXV
EXV
EXV
Protection Device
Fuse
Fuse
Fuse
Fuse
Summary of Contents for CM100N1480
Page 7: ...GREE Multi Variable Air Conditioners Indoor Unit 1 PRODUCT...
Page 51: ...GREE Multi Variable Air Conditioners Indoor Unit 45 CONTROL...
Page 52: ...GREE Multi Variable Air Conditioners Indoor Unit 46 CHAPTER 2 CONTROL 1 Operation Flowchart...
Page 95: ...GREE Multi Variable Air Conditioners Indoor Unit 89 INSTALLATION...
Page 139: ...GREE Multi Variable Air Conditioners Indoor Unit 133 MAINTENANCE...
Page 238: ...GREE Multi Variable Air Conditioners Indoor Unit 232 GMV ND30G B4B T U GMV ND36G B4B T U...
Page 266: ...JF00302921...