Operating principle and special functions for cooling
Operating principle and special functions for heating
5
Notices for use
Principle:
The air conditioner absorbs heat in the room and sends it outside, so as the indoor
ambient temperature decreases, the cooling capacity will increase or decrease based
on the outdoor ambient temperature.
Anti-freezing function
If the unit is running in COOL mode and on a low temperature, frost will form
on the heat exchanger. When the indoor heat exchanger temperature goes below 0 °C,
the indoor unit’s microcomputer will stop runnig the compressor to protect the unit.
Notices for use
Working temperature range
Indoor sideDB/WB(oC)
Outdoor sideDB/WB(oC)
Maximum cooling
32/23
48/-
Minimum cooling
21/15
10/-
Maximum heating
27/---
24/18
Maximum heating
20/---
-15/-6
The operating temperature range (outdoor temperature) for cooling unit is 10 ºC à 48 ºC
(50 ºF à 118 ºF) for cooling and heating unit is -15 ºC à 48 ºC (5 ºF à 118 ºF).
Principle:
* The air conditioner absorbs the heat in the room and sends it outside will increase, its
heating capacity will decrease by outdoor ambient temperature.
So as the indoor ambient temperature increases, so does the room heating capacity.
* If the outdoor temperature decreases, please use other heating/ventilating equipment.
Defrosting:
* When the outdoor temperature is low but the humidity is high, and the unit has been
running for a long period of time, frost will form on the outdoor unit.
The heating will stop running for 8 - 10 minutes while the auto-defrost is functioning.
* While auto-defrosting, the fan motors on both the indoor and outdoor units will stop.
* While defrosting, the indoor indicator flashes, and the outdoor unit may emit vapor.
This is due to the defrosting, and is not a malfunction.
* After the defrosting has finished,the heating will re-start automatically.
Anti-freezing function:
While in "HEAT" mode, in conjunction with one of the following statues, the indoor heat
exchanger hasn't reached the set temperature, the indoor unit will not run, in order to
prevent cool air from blowing. (Within 3 mins)
1.Heating starts.
2.After auto-defrosting ends.
3.Heating in low temperatures.
The unit's climate type can be found on the nameplate.
Pri
nci
pe
d
e f
on
cti
on
ne
me
nt
et
fo
nct
io
ns
sp
éci
ale
s e
n m
ati
ère
d
e r
efr
oid
iss
em
en
t
Pri
nci
pe
d
e f
on
cti
on
ne
me
nt
et
fo
nct
io
ns
sp
éci
ale
s e
n m
ati
ère
d
e c
hau
ffa
ge
5
In
str
uct
io
ns
d’u
til
isa
tio
n
L'a
pp
are
il
ab
so
rb
e l
a c
hal
eu
r d
e l
a p
ièc
e e
t l
’év
acu
e à
l’
ext
éri
eu
r a
fin
q
ue
la
tem
pér
a-
tu
re
am
bia
nte
in
tér
ieu
re
dim
in
ue.
L
a c
ap
aci
té
de
ref
ro
id
iss
em
en
t a
ugm
en
ter
a o
u
dim
in
uer
a s
elo
n l
a t
em
pér
atu
re
am
bia
nte
e
xté
rie
ure
.
Fo
nct
io
n a
nti
gel
Lo
rsq
ue
l’a
pp
are
il
se
tro
uve
e
n m
od
e R
EFR
OID
ISS
EM
EEN
T (
CO
OL)
e
t q
u’i
l f
ait
fr
oid
,
du
g
el
se
fo
rm
e s
ur
l’é
ch
an
geu
r d
’ai
r.
Lo
rsq
ue
la
tem
pér
atu
re
de
l’é
ch
an
geu
r d
’ai
r
in
ter
ne
est
in
fér
ieu
re
à 0
°C
(3
2 °
F),
le
m
icr
o-o
rd
in
ate
ur
de
l’a
pp
are
il
in
ter
ne
arr
ête
le
co
mp
res
seu
r p
ou
r p
ro
tég
é l
'u
nit
é..
Pri
nci
pe:
*
L ’a
pp
are
il
ab
so
rb
e l
e f
ro
id
d
e l
a p
ièc
e e
t l
’év
acu
e à
l’
ext
éri
eu
r a
fin
q
ue
la
tem
pér
atu
re
am
bia
nte
in
tér
ieu
re
au
gm
en
te.
L
a c
ap
aci
té
de
ch
au
ffa
ge
au
gm
en
ter
a o
u
dim
in
uer
a s
elo
n l
a t
em
pér
atu
re
am
bia
nte
e
xté
rie
ure
.
*
Si
la
tem
pér
atu
re
à l
’ex
tér
ieu
r d
im
in
ue,
v
eu
ill
ez
uti
lis
er
d’a
utr
es
ap
par
eil
s d
e c
hau
ffa
ge
ou
d
e v
en
til
ati
on
.
Dég
ivr
age
:
*
Lo
rsq
u’i
l f
ait
fr
oid
e
t t
rès
h
um
id
e à
l’
ext
éri
eu
r e
t q
ue
l’a
pp
are
il
n’a
p
as
fo
nct
io
nn
é
dep
uis
l
on
gte
mp
s,
du
g
el
se
fo
rm
era
su
r l
’ap
par
eil
e
xte
rn
e.
L ’a
pp
are
il
ces
ser
a d
e c
hau
f-
fer
d
e 8
à
1
0 m
in
ute
s a
fin
q
ue
le
mo
de
de
dég
ivr
age
a
uto
mat
iq
ue
so
it
act
ivé
.
*
En
m
od
e d
e d
égi
vra
ge
au
to
mat
iq
ue,
le
s m
ote
urs
d
es
ven
til
ate
urs
d
es
ap
par
eil
s i
nte
rn
e e
t
ext
ern
e c
ess
ero
nt
de
fo
nct
io
nn
er.
*
En
m
od
e d
e d
égi
vra
ge,
l’
in
dic
ate
ur
in
tér
ieu
r c
lig
no
te
et
l’a
pp
are
il
ext
ern
e p
eu
t é
met
tre
de
la
vap
eu
r.
Cel
a s
e p
ro
du
it
lo
rs
du
d
égi
vra
ge,
e
t n
on
lo
rsq
ue
l’a
pp
are
il
ne
fo
nct
io
nn
e
pas
b
ien
.
*
Lo
rsq
ue
l’a
pp
are
il
est
d
égi
vré
, i
l r
eco
mm
en
ce
à c
hau
ffe
r a
uto
mat
iq
uem
en
t.
Fo
nct
io
n a
nti
gel
:
En
m
od
e C
HA
UFF
AG
E (
HEA
T),
si
l’
éch
an
geu
r d
’ai
r d
e l
’ap
par
eil
in
ter
ne
n’a
p
as
att
ein
t u
ne
tem
pér
atu
re
do
nn
ée,
l’
ap
par
eil
in
ter
ne
ne
fo
nct
io
nn
era
p
as
afi
n d
e n
e p
as
so
uff
ler
d
e l
’ai
r
fro
id
(e
n m
oin
s d
e t
ro
is
min
ute
s).
1.
Le
ch
au
ffa
ge
déb
ute
.
2.
Le
dég
ivr
age
a
uto
mat
iq
ue
pre
nd
fi
n.
3.
L ’a
pp
are
il
ch
au
ffe
à
b
ass
e t
em
pér
atu
re.
Le
typ
e d
e c
lim
at
dan
s l
eq
uel
c
et
ap
par
eil
d
oit
ê
tre
u
til
isé
se
tr
ou
ve
su
r l
a p
laq
ue
sig
nal
éti
qu
e.
No
te
Pla
ge
de
tem
pér
atu
res
d
e f
on
cti
on
nem
en
t
Tem
pér
atu
re
int
éri
eur
e (º
C)
Te
mpé
rat
ure
ex
tér
ieu
reD
B/W
B(º
C)
Max
im
um
(R
efr
oid
iss
em
en
t)
32
/2
3
48
/-
Max
im
um
(R
efr
oid
iss
em
en
t)
21
/1
5
10
/-
Max
im
um
(C
hau
ffa
ge)
27
/--
-
24
/1
8
Max
im
um
(C
hau
ffa
ge)
20
/--
-
-1
5/-
6
La
pla
ge
de
tem
pér
atu
re
(ex
tér
ieu
re)
d
e f
on
cti
on
nem
en
t e
n c
lim
ati
sat
io
n e
st
de
de
10
ºC
à
48
ºC
(5
0 º
F à
1
18
ºF
) e
t e
n c
hau
ffa
ge
de
-1
5 º
C à
4
8 º
C (
5 º
F à
1
18
ºF
).
00638_Instruc._Bibloc_SÉRIE_CHANGE_COSY_Gree_Climatiseur Mobile8.5x11 An+FR 12-08-30 13:19 Page5