GREE Duct type split Air conditioner Inverter Series
62
sure there is no obstacle at the air inlet and air outlet. If there is any obstacle, please remove
it;
(3) The installation site shall be able to withstand the weight of outdoor unit and capable for
soundproof and vibration. The air outlet and noise of unit will not affect neighbors;
(4) The hanging of outdoor unit must use appointed hanging hole. Pay attention to protect the unit
during hanging and installation. Prohibit hitting the sheet metal to avoid rust in the future;
(5) Avoid direct sunlight;
(6) The rain and condensation water can be drained out smoothly;
(7) The outdoor unit will not be embedded by the snow and not affected by garbage and oil smog;
(8) The installation of outdoor unit shall adopt rubber damping pad or spring damper to reduce
noise and vibration;
(9) The installation dimension shall accord with the installation requirement of this manual and the
outdoor unit must be fixed at the installation site;
(10) The installation shall be done by professional technicians;
(11) For the FGR40Pd/D(2)Na-X,there are two outdoor units,Module 1 is the master controller. It
must be installed like this:
1) The diagram of connection pipe and Master control setting.
Master Module
SA6:00
Subsidiary Module
SA6:10