7. e-manage ERROR CODES
54
CODE
Error Error
Description
20
No Injector pulse from all
Not receiving an injector signal
21
No Injector 1 pulse
Not receiving injector signal I/J CH-1
22
No Injector 2 pulse
Not receiving injector signal I/J CH-2
23
No Injector 3 pulse
Not receiving injector signal I/J CH-3
24
No Injector 4 pulse
Not receiving injector signal I/J CH-4
25
No Injector 5 pulse
Not receiving injector signal I/J CH-5
26
No Injector 6 pulse
Not receiving injector signal I/J CH-6
27
No Injector A pulse
Not receiving injector signal I/J CH-A
28
No Injector B pulse
Not receiving signal I/J CH-B
31
Incorrect Injector 1 pulse
Incorrect I/J CH-1 wire to e-Manage
32
Incorrect Injector 2 pulse
Incorrect I/J CH-2 wire to e-Manage
33
Incorrect Injector 3 pulse
Incorrect I/J CH-3 wire to e-Manage
34
Incorrect Injector 4 pulse
Incorrect I/J CH-4 wire to e-Manage
35
Incorrect Injector 5 pulse
Incorrect I/J CH-5 wire to e-Manage
36
Incorrect Injector 6 pulse
Incorrect I/J CH-6 wire to e-Manage
37
Incorrect Injector A pulse
Incorrect I/J CH-A wire to e-Manage
38
Incorrect Injector B pulse
Incorrect I/J CH-B wire to e-Manage
40
NG order of Ign. signal
Incorrect wiring order of the ignition signal
41
No Ignition Signal 1 pulse
Not receiving the ignition signal IG CH-1
42
No Ignition Signal 2 pulse
Not receiving the ignition signal IG CH-2
43
No Ignition Signal 3 pulse
Not receiving the ignition signal IG CH-3
44
No Ignition Signal 4 pulse
Not receiving the ignition signal IG CH-4
45
No Ignition Signal 5 pulse
Not receiving the ignition signal IG CH-5
46
No Ignition Signal 6 pulse
Not receiving the ignition signal IG CH-6
47
JP1 PULL UP error
Incorrect Jumper setting (JP1)
48
JP1 PULL DOWN error
Incorrect Jumper setting (JP1)
49
No Ignition pulse
Not receiving the ignition signal
51
Incorrect Ignition 1 pulse
Incorrect IG CH-1 wire to e-Manage
52
Incorrect Ignition 2 pulse
Incorrect IG CH-2 wire to e-Manage
53
Incorrect Ignition 3 pulse
Incorrect IG CH-3 wire to e-Manage
54
Incorrect Ignition 4 pulse
Incorrect IG CH-4 wire to e-Manage
55
Incorrect Ignition 5 pulse
Incorrect IG CH-5 wire to e-Manage
56
Incorrect Ignition 6 pulse
Incorrect IG CH-6 wire to e-Manage
57
JP2 + 12V error
Incorrect Jumper setting (JP2)
e-01英語版 03.3.19 20:29 ページ 55