B-4 ANALOG INPUT
24
BOOST
SET VALUE
TIME
BOOST
TIME
0 kPa
Analog signal Input
This feature is used to monitor the analog input signal with the
optional External Input Signal Harness (sold separately).
See page 27 for throttle input signal setup.
• Use this feature to display useful data such as Air/Fuel Ratio and
throttle position.
1. NAME
Input name to label each input
signal channel. Input up to 8
letters.
See next page for Character
input procedure.
2. UNIT
Select the unit for the input
signal. Select a blank space if
proper unit is not one of the
options.
3. VOLT
Input the range of the input signal (minimum to maximum voltage).
Input from 0V to 16.0V at 0.01V increments.
4. CONVERSION
Input the conversion for the input signal (minimum to maximum
voltage).
-Example-
If using a Air/Fuel Ratio that reads 10 ~ 30A/F at 0 ~ 5V, input the
following;
5. WARING
Input the warning point for the input signal.
6. LOCATED
- - Warning feature will operate when the input signal exceeds
the warning setting.
- - Warning feature will operate when the input signal drops
below the warning setting.
Select the Warning feature condition.
e-01英語版 03.3.19 20:29 ページ 25