Removing a Seed Disk
1.
Remove rain cover. If seed is present, close
shutter
to prevent more seed from entering meter.
Attach funnel (page 82) or place a tarp under the row
to collect seed.
2.
Hold seed disk in meter. Rotate disk clamp
counterclockwise 45° to release disk.
3.
Tilting top of disk toward meter, slowly remove disk,
allowing seed to collect in funnel or to control flow to
tarp. Open shutter to release remaining seed up to
wing tube.
4.
Clean seed from all brushes. Clean disk seat (
in
page 64), so that new disks can seat fully.
Inspect brushes for excess wear and damage. See
“
5.
Inspect removed disks for excess wear and damage.
Set aside any disks requiring replacement. Clean
other removed disks and place in storage. See
“
6.
Re-install the rain cover (page 62).
Row Unit Shut-Off
Skip-row operations, such as planting from every other
row when switching from 30 inch twin-row to 30 inch
single-row, requires shutting down unused rows.
Shutting off seeding at a row involves 4 to 7 steps:
1.
Identify the rows to shut off (page 66).
2.
Fully close seed inlet shutter (page 66).
3.
Replace seed disk with blank disk (page 66).
4.
Lock up row unit to reduce wear (optional, page 66).
5.
Reset marker extension (Option, page 119).
6.
Reset monitor active row pattern and row spacing to
avoid nuisance alarms (see Monitor manual).
Meter drive is not disabled on 25AP row units during
shut-off.
Figure 73
Remove Disk
29611
3
Figure 74
Seed Inlet Shutter Closed
29609
2