Troubleshooting
72
Seed Pool Troubleshooting
1
Figure 83
Rear Cross-Section of Air-Pro
®
Meter in Normal and Row-Failed Conditions
29986
Normal: Filled
Bridging: Inlet Shutter
Bridging: Seed Hose
Empty Hopper
Inlet is filled to seed box. Seed
move slowly down as singulated
by meter.
A bridge at the shutter is
blocking flow.
Causes may include:
•
oversize seed
•
shutter setting too low
•
oversize matter in seed
•
excessive or sticky seed
treatment
Oversize matter in seed has
caused a bridge at the top of the
inlet.
Causes may include:
•
oversize seed
•
oversize matter in seed
•
excessive or sticky seed
treatment
No seed arriving from box.
Causes may include:
•
seed run-out
•
slide gate closed
If hopper is empty, air
back-flow
is also occurring,
which can reduce meter
pressurization at other rows
Actions:
Actions:
Actions:
Actions:
No action required.
Continue Planting.
1.
If shutter was at
suggested opening,
increase one notch.
2.
Check seed pool for
foreign matter.
3.
Resume planting.
1.
Close shutter.
2.
Tap on hose/tube
junction.
3.
Check seed pool for
foreign matter.
4.
Resume planting.
1.
If row is active,
add seed or check slide
gate.
2.
If row is inactive,
close shutter.
3.
Resume planting.