![GREAT PLAINS Yield-Pro 3P3025AH Operator'S Manual Download Page 45](http://html.mh-extra.com/html/great-plains/yield-pro-3p3025ah/yield-pro-3p3025ah_operators-manual_2259521045.webp)
3P3025AH
Operating Instructions
Great Plains
| 411-332M | 2019-02-19
41
Monitor Operation
Machines with Ground Drive Row Units
The DICKEY-john monitor operation is described in a
separate manual supplied with your 3P3025AH Planter.
The DICKEY-john PM400 system monitors the following
elements of a 2P3025AH planter:
•
Seeds at each row unit seed tube:
Medium and larger seeds are individually counted
with high accuracy. Small seed sensing may be
limited to seed stoppage (“blockage”) detection.
•
Ground speed:
The standard magnetic pickup
a
at the ground drive
allows the planter monitor to calculate and report
population.
Once setup for the planter and your display preferences,
and configured for the current crop rates/limits, the
planter monitor is typically used in the “OPERATE”
mode. Refer to the DICKEY-john
®
PM400 Operator’s
Manual for planter monitor operation details.
Both the DICKEY-john manual and this manual contain
troubleshooting information for apparent planter monitor
problems. Check both manuals, as the focus and content
is not identical.
Machines with Hydraulic Drive Row Units
The DICKEY-john monitor operation is described in two
separate manuals supplied with your 3P3025AH Planter.
The manuals are the AI-120 VT Manual and the AI-120
Quick Reference Manual.
Operations covered in that manual (and therefore not in
this manual) include:
•
Individual Row seed control
•
Seed rate calibration
•
Planting rate
•
Fertilizer rate
•
Setting rate limits and detecting out-of-limits
•
GPS integration
•
Fan rpm
a. An optional radar speed sensor is available, as are Y-cables to accept input from an existing radar on the tractor. The magnetic pickup may
be preferred, as both speed and seed flow fall to zero at lift. With radar, the planter monitor cannot tell that seeding should have stopped.
You may experience more nuisance alarms with radar.
Figure 40
PM400 Monitor Screen
31808
5.8
33.1
1 2 3 4 5 6
PM400
ENTER
ESCAPE
ACCY
SETUP
DISPLAY
&
SERVICE
GROUND
SPEED
SETUP
LIMITS
SETUP
OPERATE
PLANTER
SETUP
SPEED
AREA
MODE
SEED
COUNT
MODE
Figure 41
AI-120 Monitor Screen
68094