121
Program description: Telemetry menu
wish to use the RX CURVE option - then two curves
must be set:
RX CURVE
TYPE : A
CURVE1 CH : 02
TYPE : A
CURVE2 CH : 05
TYPE : B
CURVE3 CH : 04
5CH FUNCTION:SERVO
If you ignored this, the left and right ailerons would
exhibit different control characteristics.
The RX CURVE function can be used to manage the
control characteristics for up to three servos:
CURVE 1, 2 or 3 CH
•
Select the desired control channel (INPUT CH) for
the fi rst servo.
The following setting in TYPE only affects the chan-
nel you select at this point.
TYPE
Select the servo curve:
A
: EXPO = -100% and DUAL RATE = 125%
The servo responds slowly to stick movements
around the neutral position, but the curve becomes
steeper with increasing control travel.
B
: Linear setting
The servo follows the stick movement with a linear
response.
C
: EXPO = +100% and DUAL RATE = 70%
The servo responds slowly to stick movements
around the neutral position, but the curve becomes
steeper with increasing control travel.
Note:
The control characteristics programmed at this point
also affect mapped receiver outputs.
RX SERVO TEST
RX SERVO TEST
ALL–MIN : 1000sec
ALL–MAX : 2000sec
ALARM VOLT : 3.8V
TEST : STOP
ALARM TEMP–:–10°C
ALARM TEMP+: 70°C
CH OUTPUT TYPE:ONCE
Value
Explanation
Possible settings
ALL-MAX
Servo travel on
the “+” side for all
servo outputs in
the servo test
1500 … 2000 μs
ALL-MIN
Servo travel on
the “-” side for all
servo outputs in
the servo test
1500 … 1000 μs
TEST
Test procedure
START / STOP
ALARM
VOLT
Alarm limit for the
receiver low-
voltage warning
3,0 … 6,0 V
Default setting:
3,8 V
ALARM
TEMP+
Alarm limit for
excessive receiver
temperature
50 … 80 °C
Default setting:
70 °C
ALARM
TEMP–
Alarm limit for
excessively
low receiver
temperature
-20 … +10 °C
Default setting:
-10 °C
CH OUTPUT
TYPE
Channel sequence ONCE, SAME,
SUMI, SUMO
ALL MAX (maximum servo travel)
In this line you can set the maximum servo travel for the
servo test on the plus side of control travel.
2000 μs corresponds to full travel, 1500 μs corresponds
to the neutral position.
ALL MIN (minimum servo travel)
In this line you can set the maximum servo travel for the
servo test on the minus side of control travel.
1000 μs corresponds to full travel, 1500 μs corresponds
to the neutral position.
TEST
In this line you can start and stop the receiver’s integral
servo test.
Press the
INC+DEC
button to activate the input fi eld:
RX SERVO TEST
ALL–MIN : 1000sec
ALL–MAX : 2000sec
ALARM VOLT : 3.8V
ALARM TEMP–:–10°C
ALARM TEMP+: 70°C
CH OUTPUT TYPE:ONCE
TEST :
STOP
Now select
START
with one of the arrow buttons of the
right-hand four-way button:
RX SERVO TEST
ALL–MIN : 1000sec
ALL–MAX : 2000sec
ALARM VOLT : 3.8V
ALARM TEMP–:–10°C
ALARM TEMP+: 70°C
CH OUTPUT TYPE:ONCE
TEST :
START
Press the
INC+DEC
button to start the test-run. The
input fi eld now reverts from highlighted to “normal”:
Summary of Contents for MX-10 HOTT
Page 68: ...68 F r Ihre Notizen...
Page 69: ...69 F r Ihre Notizen...
Page 134: ...134 For your notes...
Page 135: ...135 For your notes...
Page 205: ...205...
Page 206: ...206...
Page 207: ...207...