132
Appendix
Graupner
HoTT General Engine Module
Order No.
33610
General sensor for
Graupner
HoTT receivers and models with internal-
combustion or electric power system:
2 x temperature and voltage measurements with warning thresholds
•
for min. and max. voltage and min. and max. temperature
Individual cell measurement with min. voltage warning thresholds
•
Voltage, current and capacity measurement with warning thresholds
•
for min. and max. voltage, max. capacity and max. current
Programmable current limiting
•
Current measurement with 2 x 1 mOhm shunt resistors in parallel =
•
0.5 mOhm
Rev-count measurement and warning thresholds for min. and max.
•
rotational speed
Fuel measurement with warning thresholds in 25% increments (re-
•
quires software update)
User-variable warning time: OFF, 5, 10, 15, 20, 25, 30 seconds, con-
•
stant
User-variable warning repeat time: constant, 1, 2, 3, 4, 5 min, once
•
2 x temperature measurement, optionally 0 to 120°C or 200°C, also
•
voltage measurement up to 80 V DC
1 x rev-count measurement up to 100,000 rpm with two-blade pro-
•
peller
1 x speed controller / servo input, 1 x speed governor input, 1 x
•
speed controller / servo output for rotational speed governor
etc. see product at www.graupner.de
•
Graupner
HoTT General Air Module
Order No.
33611
General sensor for
Graupner
HoTT receivers and models with internal-
combustion or electric power system:
Vario with altitude signals, climb and descent signals, and additional
•
warning thresholds for min. altitude, max. altitude, climb and two-sta-
ge descent rate
Altitude indicator (-500 … +3000 m), storage of min. and max. alti-
•
tude
2 x temperature and voltage measurements with warning thresholds
•
for min. and max. voltage and min. and max. temperature
Individual cell measurement with min. voltage warning thresholds
•
Voltage, current and capacity measurement with warning thresholds
•
for min. and max. voltage, max. capacity and max. current
Rev-count measurement and programmable speed governor, also
•
warning thresholds for min. and max. rotational speed
Fuel measurement with warning thresholds in 25% increments (re-
•
quires software update)
User-variable warning time: OFF, 5, 10, 15, 20, 25, 30 seconds, con-
•
stant
User-variable warning repeat time: constant, 1, 2, 3, 4, 5 min, once
•
2 x temperature measurement, optionally 0 to 120°C or 200°C, also
•
voltage measurement up to 80 V DC
1 x rev-count measurement up to 100,000 rpm with two-blade pro-
•
peller
etc. see product at www.graupner.de
•
Graupner
HoTT Electric Air-Module
Order No.
33620
General sensor for
Graupner
HoTT receivers and electric-powered
models:
Vario with altitude signals, climb and descent signals, and additional
•
warning thresholds for min. altitude, max. altitude, two-stage climb
and descent rate
Altitude indicator (-500 … +3000 m), storage of min. and max. alti-
•
tude.
2 x temperature and voltage measurements with warning thresholds
•
for min. and max. voltage and min. and max. temperature
Individual cell measurement 2 ... 14S with min. voltage warning
•
thresholds
Voltage, current and capacity measurement with warning thresholds
•
for min. and max. voltage, max. capacity and max. current
User-variable warning time: OFF, 5, 10, 15, 20, 25, 30 seconds, con-
•
stant
User-variable warning repeat time: constant, 1, 2, 3, 4, 5 min, once
•
2 x temperature measurement, optionally 0 to 120°C or 200°C, also
•
voltage measurement up to 80 V DC
1 x speed controller input, 1 x speed controller output for power re-
•
duction due to low voltage of individual cells
1 x current, voltage and capacity measurement, up to 150 A (peak 1
•
sec. 320 A) and up to 60 V
1 x individual cell monitoring for 2 - 14S Lithium batteries (LiPo, LiIo,
•
LiFe)
etc. see product at www.graupner.de
•