PDR 100 Fibre Channel Installation
64
PDR 100 Fibre Channel Installation
3. Use the Torx tool with the T10 bit to replace bracket retaining screw
Í
at the
side of the Profile chassis.
Installing EMI Compliance Components
NOTE: This procedure is only necessary if your PDR 100 serial number is
below B041650.
To ensure that your PDR100 remains compliant with EMI standards with the
Fibre Channel upgrade installed, you must:
1. Remove two cables behind the front panel and replace them with the cables
included in this upgrade kit.
2. Install a gasket inside the rear panel behind the power supply.
The following procedures explain how to perform these modifications.
To replace the cables:
The front panel cable assembly, Figure 24, and the LED cable assembly,
Figure 25, are on the bezel behind the front panel.
Figure 24. Front Panel Cable Assembly
9674-25