Audio 1 Source
Line, Mic, Mic48,
Front
Selects source for audio channel 1 (Only
when a Wireless adaptor is installed)
User 1
Oper
Audio 1 Level
-22dB, -28dB, -34dB,
-40dB, -46dB, -52dB,
-58dB,
-64dB
Sets input gain level for audio channel 1
(when audio gain mode is set to local).
User 1
Oper
Audio 1 HPF
Off
, On
Turns high-pass filter for audio channel 1 on
or off. Use to reduce 50 Hz and 60 Hz hum
or low frequency noise.
User 1
Oper
Audio 2 Source
Line, Mic, Mic48,
Front
Selects source for audio channel 2 (Only
when a Wireless adaptor is installed)
User 1
Oper
Audio 2 Level
-22dB, -28dB, -34dB,
-40dB, -46dB, -52dB,
-58dB,
-64dB
Sets input gain level for audio channel 2
(when audio gain mode is set to local).
User 1
Oper
Audio 2 HPF
Off
, On
Turns high-pass filter for audio channel 2 on
or off. Use to reduce 50 Hz and 60 Hz hum
or low frequency noise.
User 1
Oper
Tally
Onair Lamp
Enable
, Disable
Select enable when the tally light at the
front of the 7-inch viewfinder has to follow
the tally signal; select disable if you never
want it to light.
User 0
Oper
Tally Lock
Off,
On
Turns tally lock function on or off. When tally
lock is on, some camera controls are locked
when camera is on air.
User 3
-
Reverse Scan
Reverse Scan
Off
, On
Turns reverse scan on or off.
User 0
Scene
Mode
Horiz
, Vert, Both
Selects reverse scan mode:
Horiz = the image is flipped horizontally;
Vert = the image is flipped vertically;
Both = the image is flipped both horizontally
and vertically.
User 0
Scene
Exposure
Lighting
-10..+10
(0)
Sets the exposure correction to fine-adjust
for ambient lighting frequency when
exposure mode is 50 Hz or 60 Hz.
User 1
Scene
Clean Scan
Cl.Scan Mode
Extended,
Normal
Selects clean scan mode:
Normal (VAR2 on OCP/MCP) = shutter is
running (no smear);
Extended (VAR1 on OCP/MCP) = shutter is
not running (more accurate clean scan but
possible vertical smear).
User 1
-
Value
50.8.. 125.0 Hz (50 Hz) /
61.0 .. 150.0 Hz (60 Hz)
or
19.6 .. 7.9 ms (50 Hz) /
16.3 .. 6.6 ms (60 Hz)
Select clean scan frequency.
User 1
-
Units
Hz
, mSec
Selects display units for clean scan.
User 1
-
Gain Preset
Gain - (dB)
-3dB
, -6dB
Selects gain value for - preset.
User 2
Oper
Install
Values
Description
Level
File
Summary of Contents for LDK 4000 ELITE -
Page 1: ...3922 496 31341 December 2009 v1 01 LDK 8000 Elite 4000 Elite User s Guide System camera ...
Page 14: ...14 LDK 8000 Elite 4000 Elite System camera User s Guide v1 01 ...
Page 20: ...20 LDK 8000 Elite 4000 Elite System camera User s Guide v1 01 Chapter 1 Introduction ...
Page 36: ...36 LDK 8000 Elite 4000 Elite System camera User s Guide v1 01 Chapter 3 Configurations ...
Page 101: ...LDK 8000 Elite 4000 Elite System camera User s Guide v1 01 101 Chapter 6 System menu ...
Page 102: ...102 LDK 8000 Elite 4000 Elite System camera User s Guide v1 01 Chapter 6 System menu ...
Page 114: ...114 LDK 8000 Elite 4000 Elite System camera User s Guide v1 01 Chapter 7 Connectors ...
Page 122: ...122 LDK 8000 Elite 4000 Elite System camera User s Guide v1 01 Chapter 8 Specifications ...