40
RollCall Control Panel
Time Sync Configuration
Interface Status Details
Item
Description
Last Lock
Time when PTP last locked.
Lost Lock
Time when PTP last lost lock.
1 Step syncs
Increments on reception of Sync message that has the
twoStepFlag
=false.
2 Step Syncs
Increments on reception of Sync message that has the
twoStepFlag
=true.
Follow Ups
Increments on reception of every
follow_up
message.
Delay Requests
Increments on reception of every
delay_req
message.
Delay Responses
Increments on reception of every
delay_resp
message.
Announcement Messages Increments on reception of every announce message.
Signaling
Increments on reception of each PTP Signaling message.
Management
Increments on reception of each PTP Management message.
Version Errs
The IQMIX supports PTPv2 only.
If a PTPv1 message is received, it is discarded, and this counter
incremented. This would be an indication that the
grandmaster clock is not configured correctly.
Unknown Msgs
If the product receives messages on the PTP multicast address
port 319 or 320 that are not messages defined as PTP ones
this counter is incremented.
Length Errs
PTP messages with an invalid length cause this counter to
increment.
Unexpected 2 Steps
Increments on the reception of a
follow_up
message but the
sync message is indicating 1 step.
RX Timestamp Errs
Increments for every PTP message where the sequence
number is as expected but its timestamp is not valid.
TX Timestamp Errs
Increments for every
delay_resp
message where its
sequence number is as expected but its timestamp is not
valid.
Av Delay
This is the average network delay time from the grandmaster
to the UCP. This should be stable and in the order of 10-20μs.
Av Error
The average error is the difference between the grandmaster
and the UCP local clock. If locked, this number will be small.
Sync Interval
From IEEE1588 7.7.2.1: "For each of the message types
Announce
,
Sync
,
Delay_Req
and
Pdelay_Req
, the mean time
interval between successive messages shall be represented as
the logarithm to the base 2 of this time interval measured in
seconds on the local clock of the device sending the message.
The values of these logarithmic attributes shall be selected
from integers in the range ?128 to 127 subject to further limits
established in an applicable PTP profile. The interpretation of
the
logMessageInterval
depends on the message type; see
13.3.2.11. Except for
Delay_Req
messages (see 9.5.11.2), a
node shall, with 90% confidence, issue messages with
intervals within ±30% of the stated value of this attribute."
Summary of Contents for IQMIX25 Series