background image

93

IQMIX25/40

User Manual

Ethernet Gb

The 

Ethernet Gb

 (Gigabit) page shows details and status of the on-module Ethernet 

connector. The IQMIX defaults to use of DHCP, but this can be overridden and a static IP 
address specified if required.

The Ethernet Pane

The 

Ethernet

 pane displays details of the currently selected network interface, and allows a 

static IP address to be defined. Enter information as required, then click 

S

 to save. New settings 

are applied when 

Restart

 is clicked.

Ethernet Arcnet

Not currently used.

Ethernet Front Page

Ethernet Arcnet Page

Summary of Contents for IQMIX25 Series

Page 1: ...User Manual Issue 2 Revision 1 2020 09 22 IQMIX25 40 3G HD SD SDI MULTI CHANNEL 10 25 40GBE IP TRANSCEIVERS...

Page 2: ...using IQMIX25 40 documentation you agree to the following terms and conditions Grass Valley hereby grants permission and license to owners of IQMIX25 40 to use their product manuals for their own inte...

Page 3: ...ent connections Identifies an external protective grounding terminal which may be connected to earth ground as a supplement to an internal grounding terminal Indicates that static sensitive components...

Page 4: ...l before connecting power Prior to servicing remove jewelry such as rings watches and other metallic objects To avoid fire hazard use only the fuse type and rating specified in the service instruction...

Page 5: ...me to safely ground unwanted ESD voltages If no wrist strap is available ground yourself by touching the unpainted metal part of the chassis For safety periodically check the resistance value of the a...

Page 6: ...ifie une borne de mise la terre externe qui peut tre connect e en tant que borne de mise la terre suppl mentaire Signale la pr sence de composants sensibles l lectricit statique et qui sont susceptibl...

Page 7: ...lisez uniquement un chiffon humide Des tensions dangereuses peuvent exister en plusieurs points dans cet quipement Pour viter toute blessure ne touchez pas aux connexions ou aux composants expos s lor...

Page 8: ...ut se produire lorsque des composants lectroniques ne sont pas manipul s de mani re ad quate ce qui peut entra ner des d faillances intermittentes ou endommager irr m diablement un circuit lectrique A...

Page 9: ...lisation Si l cran LCD ou TFT est bris manipulez les fragments de verre avec pr caution au moment de vous en d barrasser veillez ce que le cristal liquide n entre pas en contact avec la peau ou la bou...

Page 10: ...ycling information Grass Valley believes this environmental information to be correct but cannot guarantee its completeness or accuracy since it is based on data received from sources outside our comp...

Page 11: ...m its holder using a blunt instrument for leverage such as a screwdriver if necessary In some cases the battery will need to be desoldered from the PCB 4 Dispose of the battery and equipment according...

Page 12: ...ting conditions Unused optical outputs should be covered to prevent direct exposure to the laser beam Even though the power of these lasers is low the beam should be treated with caution and common se...

Page 13: ...PORTS For unconnected signal data ports on the unit fit shielding covers For example fit EMI blanking covers to SFP type ports and fit 75 RF terminators to BNC type ports COAXIAL CABLES Coaxial cable...

Page 14: ...xiv Notices...

Page 15: ...View 21 Feature Summary 23 IQMIX25 3G HD SD SDI Multi channel IP Transceiver 23 IQMIX40 3G HD SD SDI Multi channel IP Transceiver 23 Enclosures 24 4U B style Enclosure 24 3U B style Enclosure 24 IQFA...

Page 16: ...P Receiver Audio Stats 57 About Flow IDs 57 Ethernet RTP Receiver Meta Stats 58 About Flow IDs 58 Link Control 59 UHD Links 59 TPG 59 HDR Control 60 Destination Timing 62 Audio V Fade 63 Audio Type Co...

Page 17: ...xvii IQMIX25 40 User Manual Ethernet Arcnet 93 Interop Page 94 SFP Configuration Page 96 Contact Us 97...

Page 18: ...xviii Table of Contents...

Page 19: ...E 2042 VC2 lightweight compression allows for high quality signal carriage whilst optimizing bandwidth requirements while sending signals uncompressed provides best quality transport although at the e...

Page 20: ...B frame IQMIX4010 2B3 16 channel SDI to IP transceiver with 10GbE interface Up to 16 SDI inputs or outputs 2 x 10GbE ports IQMIX4011 3B3 16 channel SDI to IP transceiver with 10GbE interface Up to 16...

Page 21: ...21 IQMIX25 40 User Manual Rear Panel View The following rear panel types are available IQMIX4000 2B3 IQMIX4001 3B3 IQMIX4010 2B3...

Page 22: ...22 Introduction Rear Panel View IQMIX4011 3B3 IQMIX2500 2B3 IQMIX2501 3B3...

Page 23: ...02 3 RollCall control and monitoring compatible with standard logging and reporting features IQMIX40 3G HD SD SDI Multi channel IP Transceiver Handles up to 16 SDI signals over dual 10GbE or dual 40Gb...

Page 24: ...P 3U B style Enclosure Enclosure order codes IQH3B S 0 IQH3B S P Note Although IQ modules are interchangeable between enclosures their rear panels are enclosure specific An IQH3B enclosure accepts mo...

Page 25: ...g the blanking plate covering the chosen slot position Remove and store the blanking plate in a safe place for future use 3 Ensuring correct orientation fit the fan module rear connecting panel to the...

Page 26: ...26 Introduction Enclosures...

Page 27: ...Signal Outputs 3G HD SD SDI Outputs Up to 16 16 12 8 4 0 Connector Format HD BNC 75R Conforms to 3G SDI to SMPTE 424M 425M level A B compatible HD SDI to SMPTE292M 274M 296M SD SDI to SMPTE259M C Ethe...

Page 28: ...ors Front Panel and Card Edge Front Panel and Card Edge Green Power OK Green flashing CPU OK 16 x Input standard detection LEDs Off Input Spigot not in use Red No input Yellow TPG Green Video flow det...

Page 29: ...puts 16 x 3G HD SD SDI interfaces provided with HD BNC 10 25G Ethernet SFP SFP supporting 10 25G Ethernet 40G Ethernet QSFP QSFP supporting 40G Ethernet SFP Link LED Indicators SFP QSFP LEDs indicate...

Page 30: ...30 Connections SFP Link LED Indicators...

Page 31: ...igot output IP flow for Receiver spigot For UHD Quad Link Modes Banks of four adjacent LEDs e g 1 4 5 8 etc will light simultaneously to denote the 4 x 3G streams being received on a UHD input If a TP...

Page 32: ...32 Card Edge LEDs...

Page 33: ...here on the pages will also open a page view list allowing quick access to any of the pages Template Pages The following pages are available Configuration see page 36 Time Sync Configuration see page...

Page 34: ...e 79 Logging FPGA see page 82 Logging Spigot 1 x see page 83 Logging NMOS see page 86 Logging Card Diagnostics see page 87 Rolltrack see page 88 Loopback Router see page 90 Setup see page 91 Ethernet...

Page 35: ...uts to display data for from the SDI Selection drop down list Select Video Input Status Video Output Status or Network Status from the Information Select pane as required The selected information will...

Page 36: ...IO Displays how input and output spigots are currently configured See Card Firmware Software Version below for information on how to change this Where Am I Causes the front edge LEDs to flash allowin...

Page 37: ...ed down prior to restarting the module See Defaults on page 92 for more information 3 Click Restart to restart the module and implement any changes made GUID Displays the absolute unique identifier as...

Page 38: ...ted So the two systems will not give identical results Options are PTP Multicast this uses multicast for both sync and follow up messages PTP Unicast this uses multicast for the sync messages and unic...

Page 39: ...Ethernet 1 If Ethernet 1 is available it has priority Thus if we have failed from Ethernet 1 to Ethernet 2 as soon as Ethernet 1 becomes available again we will switch back Ethernet 2 as per Ethernet...

Page 40: ...counter to increment Unexpected 2 Steps Increments on the reception of a follow_up message but the sync message is indicating 1 step RX Timestamp Errs Increments for every PTP message where the sequen...

Page 41: ...ved within any 2 second period follow_up delay_resp sync announce Clock Steps Back If the IQMIX receives a time earlier than the last this counter is incremented This could be because of a fault with...

Page 42: ...42 RollCall Control Panel Time Sync Configuration Histogram pane Visible Clocks Displays the grandmaster clocks present on the network Visible Clocks pane...

Page 43: ...owing options are available for each spigot If a test pattern is applied either a pattern or a tone the spigot cannot be used for streaming any other essence Click Show Caption to overlay a caption on...

Page 44: ...ot by spigot basis The following options are available for each spigot If a test pattern is applied either a pattern or a tone the spigot cannot be used for streaming any other essence Receiver TPG Pa...

Page 45: ...45 IQMIX25 40 User Manual Counters The Counters page allows the various timers provided by the module to be reset to zero Click the appropriate Clear button to zero a counter Counters Page...

Page 46: ...he Configuration page see Configuration on page 36 for more information The following facilities are available from this page FEC Page Option Operation FC FEC displayed only if a relevant configuratio...

Page 47: ...lays the number of corrected and uncorrected errors received via the SFPs Click Enable Stats to activate and Clear Count to zero the counters FEC Logging Information on several parameters can be made...

Page 48: ...Media Open Specifications collectively known as NMOS have been developed to provide interoperability between a wide range of products from various manufacturers NMOS effectively provides a control and...

Page 49: ...by which the module will be known in the NMOS registry See also Label Patterns below Auto Displayed if Registry Mode see above is set to Auto DNS IP displays the current DNS IP address and allows a ne...

Page 50: ...ttern Fields Leaving the Sender Receiver Pattern fields empty will result in the default Grass Valley text string labels for IP Senders Receivers being used If a minimum of one variable is entered the...

Page 51: ...ble Description dev Device label spig Spigot number starting from s_snum or r_snum flow Flow number flowalt Flow number with alternate formatting Restarts at 1 for each flow format type fmt Flow forma...

Page 52: ...t Values The default description values listed above may be updated if required To do this simply overwrite the default value as displayed in the Sender Receiver Variables fields with the required val...

Page 53: ...en Restart is clicked Where Am I Checkbox When enabled the Where Am I function causes the SFP QSFP LEDs for the relevant Ethernet connector to flash allowing the module to be physically located Clear...

Page 54: ...t 1 and 2 RTP Sender Ethernet 1 and 2 RTP Sender The RTP Sender page displays the amount of data transmitted on a spigot by spigot basis Units are megabits per second Click Enable Stats to display val...

Page 55: ...lays the amount of data received plus details of packet loss on a spigot by spigot basis Units are megabits per second Click Enable Stats to display values click Clear RTP Count or Clear Error Count t...

Page 56: ...a port bandwidth utilization if spigot addresses match across multiple interfaces then they are allocated to the same Flow ID This means that if multiple spigots are assigned to the same Flow ID and t...

Page 57: ...utilization if spigot addresses match across multiple interfaces then they are allocated to the same Flow ID This means that if multiple spigots are assigned to the same Flow ID and the IP addresses a...

Page 58: ...ia port bandwidth utilization if spigot addresses match across multiple interfaces then they are allocated to the same Flow ID This means that if multiple spigots are assigned to the same Flow ID and...

Page 59: ...o carry 12G Disable SDI Sync Bit some older SDI receiving equipment may not support sync bit insertion When transmitting signals to these devices sync bit insertion can be disabled by checking the box...

Page 60: ...s displayed against output spigots Select options from the drop down menus for each spigot as required then click Take to apply the changes The following options are available Note When UHD quad link...

Page 61: ...61 IQMIX25 40 User Manual Option Description Colorimetry Available values are BT709 BT2020 Other Color Space Available values are YCbCr ICtCp Bit Depth Available values are 10bit 10bit Full range...

Page 62: ...n Timing Page Option Description Genlock Timing V Offset Vertical timing offset in lines Genlock Timing H Offset Horizontal timing offset in pixels Receiver Packet Buffer Frames Delay The receiver pac...

Page 63: ...ows audio fading to be applied on a spigot by spigot basis in order to minimize audio disruption When applied the audio will fade down on input loss and perform an audio V fade down then up during inp...

Page 64: ...Type Control Audio Type Control The Audio Type Control page allows audio pairs to be marked as carrying PCM or non PCM Only pairs on IP receiver spigots are displayed Audio Type Control page Enable ch...

Page 65: ...the module s response to signal loss Select as required Options upon signal loss are Input Loss Control Page Option Operation Freeze Picture will freeze Black Picture will cut to black TPG Picture wil...

Page 66: ...n the capabilities of the software version firmware selected Input Spigots Input spigots are defined by selecting the appropriate firmware version on the Configuration page See page 36 for more inform...

Page 67: ...um expected bandwidth requirement for this spigot Sender Pane Ext Headers Extended header operation can be adjusted for TR 03 TR 04 compatibility Extended headers provide in band metadata regarding th...

Page 68: ...a status and allows multicast IP and port details to be defined for the selected spigot To set multicast details for the spigot Enter IP and Port details as required Enter the appropriate details in t...

Page 69: ...by selecting the appropriate firmware version on the Configuration page See page 36 for more information Spigot Pane The Spigot pane provides basic monitoring for the selected Spigot Click Take to ap...

Page 70: ...f audio channels is known select the number present on this spigot Otherwise set to Auto Audio Delay Move the slider to set an Audio Delay as required Click P to return to the preset default value Mak...

Page 71: ...s To set multicast details Select the required video output standard from the drop down list Enter multicast IP and port details as required Make a selection from the Flow Type drop down menu if requi...

Page 72: ...og information should be collected Log Field Displays the name of the logging field Log Value Displays the current log value The information below describes the various parameters available for loggin...

Page 73: ...ys the name of the logging field Log Value Displays the current log value The following options are available Enable check boxes to activate log fields as required Logging System Page Log Field Descri...

Page 74: ...the slot in the rack where IQMIX is located POWER_USAGE Reports the power usage in Watts A type rack PR Units B type rack TEMP_N_CELSIUS Reports the temperature status of the FPGA TEMP_N_NAME Temperat...

Page 75: ...to be constant TIMESYNC_N_AVG_ERROR The current difference between the cards time and the grandmaster time Should be close to zero once card has synchronized TIMESYNC_N_STDV_ERROR The standard deviati...

Page 76: ...YNC_N_REQUEST_ INTERVAL Logs the PTP Delay Request Frequency setting as set on the Time Sync Configuration page See page 38 TIMESYNC_N_ PREFERENCE Logs the PTP Network Interface Preference setting as...

Page 77: ...tion should be collected Log Field Displays the name of the logging field Log Value Displays the current log value The following options are available Enable check boxes to activate log fields as requ...

Page 78: ...WARN LOW DATA FAIL LAN_PORT_N_CPU_TRAF_ OUT_STATE CPU traffic out state Valid values are OK WARN LOW DATA FAIL LAN_PORT_N_RTP_DIS_ RATE RTP Discontinuity state LAN_PORT_N_LINK_STATE Ethernet link stat...

Page 79: ...nable Select the check boxes that correspond to the parameters for which log information should be collected Log Field Displays the name of the logging field Log Value Displays the current log value T...

Page 80: ...RX LOS RX Failure FAIL TX LOS TX Failure FAIL EQ Fault EQ Failure FAIL RX LOL RX Loss of Lock FAIL TX LOL TX Loss of Lock FAIL Temp FAIL VCC SFP_N_TYPE Displays Q SFP identifier from device SFP_N_VEND...

Page 81: ...w Low but in tolerance WARN High High but in tolerance SFP_N_WAVELENGTH Displays transmit wavelength in nm SFP_N_X_LASER_BIAS Displays bias level in mA SFP_N_X_TX_POWER Displays transmit power level i...

Page 82: ...ns are available Enable check boxes to activate log fields as required Where N is the input number Logging FPGA Page Log Field Description TEMP_N_NAME Reports temperature sensor name TEMP_N_CELSIUS Re...

Page 83: ...g fields to be enabled for each available spigot Depending on whether the spigot is an input or an output the appropriate log fields are shown An additional field is provided for the user to optionall...

Page 84: ...ected INPUT_N_TYPE HD SD 3G SDI INPUT_N_STANDARD PAL NTSC 625 Mono 525 Mono INPUT_N_STREAM Not to be used if the spigot is part of a UHD Quad Link configuration Use INPUT_N_LINK_M_ STATUS in this case...

Page 85: ...i p sf Where Lines Total lines Active Active lines Rate Frame rate I interlaced P Progressive SF Segmented Frame For example 1080 50p or 1125 1080 25i OUTPUT_N_MAKE_ BREAK Reports Make before Break or...

Page 86: ...Where N is the input output number Option Description NMOS_STATUS Displays the current NMOS status Valid values are OK Off NMOS functionality is disabled OK Registered the module has been successfull...

Page 87: ...mber Logging Card Diagnostics Page RollTrack Source Description NVRAM_FS Reports NVRAM file system TOTAL_AVAILABLE_ MEMORY Reports total amount of CPU memory available TOTAL_USED_MEMORY Reports total...

Page 88: ...Unused is displayed Where N is the input number RollTrack Address This item enables the address of the selected destination unit to be set The address may be changed by typing the new destination int...

Page 89: ...d Possible messages are RollTrack Status A message is displayed here to indicate the status of the currently selected RollTrack index Possible RollTrack Status messages are Message Description No The...

Page 90: ...backup in case of Ethernet failure If an Ethernet failure is encountered 1 Use the matrix radio buttons to specify which inputs should be routed to which outputs 2 Select the Video Flow to Use SMPTE...

Page 91: ...cal assistance Setup Page Item Description Product Name of the module Software Version Currently installed software version number Firmware Version Currently installed firmware version number Serial N...

Page 92: ...defaults Feature Mod Level Daughterboard PCB modification level Feature HW Build Factory Daughterboard hardware build number Option Operation Default settings All controls are reset to their default v...

Page 93: ...e overridden and a static IP address specified if required The Ethernet Pane The Ethernet pane displays details of the currently selected network interface and allows a static IP address to be defined...

Page 94: ...roperability with third party equipment The following facilities are available from this page Interop Page Option Operation Stream Synchronization Controls Audio Extended Headers Enable to use extende...

Page 95: ...onize metadata to video Meta Frame Delay Allows a frame delay for metadata received on the spigots shown to be set Use the sliders to adjust as required Click P to use the preset default value RTP Pay...

Page 96: ...untered with an SFP not working as expected follow these instructions 1 Select the appropriate SFP type from the SFP Database List and click Take Verify whether the SFP is now working correctly if so...

Page 97: ...n a local phone number for the support center nearest you please consult the Contact Us section of Grass Valley s website at www grassvalley com An online form for e mail contact is also available fro...

Page 98: ...98...

Reviews: