78
Ignite SDC/HDC Robotic Camera Instruction Manual
Appendix B — SD (PAL) Camera Block
Specifications
SD (PAL) camera specifications are listed in
Table 32. SD Camera Specifications
Power Requirements
12 Vdc 15.4 W
Optical System
2/3” Prism optical system, F1.4
Pickup Device
2/3” Interline wide CCD
Total Pixels
1008 (H)x591 (V) (About 540000 pixels)
Scanning System
629 lines, 50 fields, 25 flames
SYNC System
Internal: PAL standard
External: BBS or VBS (BNCx1, Dsub 50 Px1)
Video Output
Composite: 1.0 Vp-p/75 Ohm (BNCx1, Dsub 50 Px1)
Y/C Y: 1.0 Vp-p/75 Ohm; C: 0.3 Vp-p/75 Ohm (burst) (Dsub 50 Px1)
Y/Pr/Pb Y: 1.0 Vp-p/75 Ohm; Pr, Pb: 0.525 Vp-p/75 Ohm (Dsub 50 Px1)
RGB G: 1.0 Vp-p/75 Ohm; RB: 0.7 Vp-p/75 Ohm (Dsub 50 Px1)
Std Illumination Color Temp
2,000 lx (F11, 3200 K)
Minimum Illumination
0.4 lx (F1.7, Night Eye H)
S/N Ratio
63 dB (Y signal, DTL OFF, gamma OFF, DNR ON)
Horizontal Resolution
850 TV lines (high band DTL ON, center area)
Registration
0.05% (Entire screen, excluding effects of lens)
Aspect Ratio Conversion
16:9, 4:3
Contour Correction
Horizontal, vertical (2H)
White Balance
AWC A, AWC B (R/B gain, painting), ATW, 3200K, 5600K preset
Black Balance
Auto (R/B pedestal, painting function)
Chroma Variability
7 levels
Encoding System
Y, R-Y, B-Y
Gain Selection
0 to 30 dB in step, AGC, Night Eye L/H
Electronic Shutter Speed
1/120, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10000, ELC, Synchro
scan (50.24 Hz to 15.63 kHz)
CCD Readout Selection
Field, Flame 1, Flame 2
Color Bars
Full
Lens Mount
2/3” bayonet mount
Lens Diaphragm
Auto, Manual (Only with remote control) Adjust, On, Off
Selectors
MENU
ITEM/AWC (AWC: when menu screen is not displayed)
YES/ABC (ABC: when menu screen is not displayed)
NO/BAR (BAR: when menu screen is not displayed)
Input/Output Connectors
VIDEO OUT: BNC connector
G/L IN: BNC connector
IRIS: 12 P round connector
DC 12 V IN: DC connector
I/F REMOTE: 50 P Dsub connector
Indicators
Red LED: Power On
Allowable Temperature Range
For storage: –4 °F to 140 °F (–20 °C to +60 °C)
For guaranteeing performance: 41 °F to 95 °F (+5 °C to +35 °C)
For guaranteeing operation: 14 °F to 113 °F (–10 °C to +45 °C)
Allowable Humidity Ranges
For storage: 20% to 90%, for operation: 20% to 90%
Dimensions (WxHxD)
3-5/16”x3-3/4”x7-9/16” (84x95x192 mm)
Weight
2.5 lbs (1.15 kg)
Summary of Contents for Ignite HDC Series
Page 8: ...8 Ignite SDC HDC Robotic Camera Instruction Manual Contents ...
Page 10: ...10 Ignite SDC HDC Robotic Camera Instruction Manual Preface ...
Page 22: ...22 Ignite SDC HDC Robotic Camera Instruction Manual Section 1 Overview ...
Page 36: ...36 Ignite SDC HDC Robotic Camera Instruction Manual Section 3 Operation ...
Page 40: ...40 Ignite SDC HDC Robotic Camera Instruction Manual Section 4 Service ...
Page 106: ...106 Ignite SDC HDC Robotic Camera Instruction Manual Appendix C HD Camera Block ...
Page 110: ...110 Ignite SDC HDC Robotic Camera Instruction Manual Appendix D Robotic Pan Tilt Head ...
Page 116: ...116 Ignite Glossary Glossary ...