MV-801 User Manual
Issue 1 Revision 1
Page 48
A.5 Streamed ‘Input-Copy’ Outputs
A.6 Rear Panel Connectors
The MV-800-RP Rear Panel is used on MV-801 and the module number is 1312. See Figure 6 on
page 15 for an illustration of the Rear Panel connectors.
Signal
IP Stream Outputs
MV-801-H264
license
required.
Up to 48-off streamed ‘input-copy’ outputs. Streaming out of
scaled, H.264-encoded Multiviewer video ‘input-copies’.
Each multiviewer input can be H.264 encoded to create
streamed, scaled copies of the 48 inputs. These are streamed out
over IP.
H.264 encoding latency is approximately 2 video frames.
(For information about ‘end-to-end’ viewing latency, please refer
to the
MV-8 Series Core Multiviewer
user manual.)
These can be viewed on desktop PCs via Orbit. Applications
include: confidence monitoring, compliance monitoring.
Note:
The H.264 streams do not function for the following
slower-frame-rate HD standards:
•
1080p30 (and slower frame rates); and
•
720p30 (and slower frame rates).
Applications include: confidence monitoring, compliance
monitoring.
Connectors
Multiviewer Display
Outputs
1 to 12
6-off SFP cages. Each for an SFP video module:
•
2-off SDI Coax, HD-BNC.
•
or 2-off SDI Fiber.
•
or 1-off HDMI.
HDMI
Not currently used.
USB
For engineering use only.
LTC & GPIO
1 x 26 Way High Density D-Type female connector,.
MV-800-RP Multiviewer Rear Panel (1312)
for wiring details and pin-out.
1G Ethernet
2 x 1 Gbps SFP+ cages for Ethernet SFPs.
Ethernet socket RJ45.
10G Ethernet
Not currently used.
2 x 10 Gbps SFP+ cages for Ethernet SFPs.
Ethernet socket RJ45. Interfaces are not used.