Specifications
4-7
4.3
Accessory/Option Specifications
Control Software
Accessories
Battery Pack B-517 (Option)
Item
Description
Compatible operating system Windows 2000/XP
Functions
Main unit control, realtime data capture, data conversion
Main unit settings
Input settings, memory settings, alarm settings, trigger settings
Allowed connection
up to 10
Number of channels per
200 ch maximun
connection
Maximum number of channels 500 ch maximun
Settings
AMP settings, data settings, trigger/alarm settings, report settings, others
Captured data
Realtime data (CSV, Binary)
Memory data (CSV, Binary)
USB memory data (CSV, Binary)
Display
Analog waveforms, logic waveforms, pulse waveforms, digital values
Display modes
Y-T View, X-Y View, Digital View, Meter View, Report View
File conversion
Between cursors, All data
Monitor functions
Alarm monitor enables sending of email to the specified address
Dual-screen function
Displays the current data alongside past data
Statistic/History
Displays maximum, minimum and average values during measurement
Report function
Enables creation of daily or monthly files
Item
Description
Capacity
7.2 V/2200 mAh
Battery type
Lithium secondary battery
Running time
Up to two packs can be mounted
<When LCD is ON>
Battery pack x 1 (brightness MAX)
: approx. 2.5 hours
Battery pack x 1 (brightness MIN)
: approx. 3 hours
Battery pack x 2 (brightness MAX)
: approx. 5 hours
Battery pack x 2 (brightness MIN)
: approx. 6 hours
<When LCD is OFF>
Battery pack x 1
: approx. 4.5 hours
Battery pack x 2
: approx. 9 hours
Note: When capturing to internal memory at 1 s, sampling, 20 channel terminals, using
new battery packs at +25
°
C environment.
Note: The running time depends on the operating environment.
Charging method
Mount in the main unit
Time required for charging
Battery pack x 1
: approx. 4 hours
Battery pack x 2
: approx. 8 hours
Switchover in the case of
Because the battery is used together with the AC adapter, the power supply
a power failure
will be switched automatically to the battery in the event of a power failure.
Note: The AC adapter is the primary power source.
Operation environment
15 to 40
°
C
Other functions
• When the battery is running low, file is closed automatically.
(when captured to internal memory or USB memory)
• remaining amount indicator
Item Name
Description
Quantity
Quick Start Guide
GL800-UM-8xx
1
CD-ROM
GL800-CDM0xM (User Manual, Application software)
1
AC adapter
100 to 240 VAC, 50/60 Hz, Power supply cord for each area
1 set