background image

II

Usage precautions

Do not lift or move the scanner by holding the top cover section, as doing so may damage the
scanner. Always lift the scanner by holding the underside.

OK

NG

Top cover section

Take care not to get your fingers caught in the gap between the top cover and the scanner unit when
opening and closing the top cover.

<Closing the top cover>

Keep your hands away from the front of the

 scanner when closing the top cover.

<Opening the top cover>
Do not hold the rear section of the 
top cover when opening it.

Top cover

Top cover

Always ensure that you open the top cover and remove the cushion material before using the
scanner. (See Section 4.1, “Opening and Closing the Top Cover”.)

Scanner warm-up

A warm-up period is not usually required for the CSX300-09. However, if you plan to scan a color
document (in particular a document with many light colors), we recommend that you allow the
scanner to warm up for 10 minutes before scanning the document.

Summary of Contents for CSX300-09

Page 1: ...CSX300 09 USER S MANUAL MANUAL NO CSX300 UM 151 IMAGE SCANNER...

Page 2: ...g the manual This category provides information that if ignored is highly likely to cause fatal or serious injury to the operator This category provides information that if ignored is likely to cause...

Page 3: ...necklaces Objects such as glasses vases houseplants etc that contain water or other fluids If any of these objects does come into contact with the internal electrical components immediately turn off t...

Page 4: ...nstall use or store the scanner in a location that does not meet the specified temperature and humidity ranges Such location may impair the scanner s performance due to deformation or damage and cause...

Page 5: ...n a fire hazard or electric shock Make sure that the power cable is firmly inserted into the power outlet Use of a power cable when the plug is not completely inserted into the power outlet may result...

Page 6: ...or metallic matter to adhere to the power plug If the power plug becomes dirty thoroughly wipe it clean The use of a dirty power plug may result in a fire hazard or electric shock As a general rule do...

Page 7: ...cause a fire hazard or electric shock if it comes into contact with the scanner s internal electrical components Before moving the scanner make sure that the power button is in the off position and t...

Page 8: ...remove the power plug from the power outlet and either contact the store where you purchased your scanner or your nearest Graphtec representative Do not insert your hands inside the scanner during a s...

Page 9: ...ctric shock Caution At least once a year remove the power plug from the power outlet and clean the prongs and surrounding areas A build up of dust may result in a fire hazard When cleaning or checking...

Page 10: ...ainst harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may caus...

Page 11: ...o liability for damages resulting from either the use of the information contained herein or the use of the product Registered Trademarks All names of companies brands logotypes and products appearing...

Page 12: ...rom the front of the scanner when closing the top cover Opening the top cover Do not hold the rear section of the top cover when opening it Top cover Top cover Always ensure that you open the top cove...

Page 13: ...taching and using the cable clamp 1 4 CHAPTER 2 CONNECTION AND PREPARATIONS 2 1 Connecting to the Power Supply 2 1 2 2 Turning the Power On and Off 2 2 Turning the Power On 2 2 Turning the Power Off 2...

Page 14: ...ter connection to the computer 5 1 5 3 The control panel s red ERROR LED is lit 5 1 5 4 The control panel s red ERROR LED is flashing 5 2 5 5 The document isn t properly fed to the initial scanning po...

Page 15: ...ge Check to confirm that all of the items shown below are present If any item is missing promptly contact the store where you purchased your scanner or your nearest Graphtec representative Scanner uni...

Page 16: ...he scanner is turned off 6 PAPER LED green Lit Lights when a document has been loaded Flashing Flashes while image data is being scanned Unlit Normal status Local status 7 ERROR LED red Lit Lights to...

Page 17: ...11 Power inlet 12 Main power switch 10 USB connector 13 Document support plates 14 Cable clamp 10 USB connector Used to connect the USB interface cable 11 Power inlet Used to connect the power cable 1...

Page 18: ...r Checkpoint Detach the document support plates when moving or packing the scanner Lift the plates up and out of the slots to detach them Attaching and using the cable clamp Attach the cable clamp to...

Page 19: ...el off the adhesive sticker on the rear of the clamp and then attach the clamp to the scanner Cable clamp Using the clamp 1 Pull up the latch at the top of the cable clamp to open the clamp Latch 2 Pa...

Page 20: ...nner s power inlet and the other end to an AC power outlet of the rated supply voltage Power inlet AC power outlet Power cable Caution Be sure to use the cable clamp provided with the scanner to faste...

Page 21: ...control panel When the scanner is in the power on status the POWER button LED lights blue ON Turning the Power Off Press the POWER button on the scanner s control panel When the scanner is in the pow...

Page 22: ...lashes after approximately 12 minutes have elapsed without a document being loaded in the scanner To return the scanner to normal status Local status press either the STOP or the EJECT key To cancel t...

Page 23: ...needed further Recommended environment CPU Pentium 4 2 GHz Memory 1 GB or more Disk space At least 30 GB USB 2 0 interface that comes standard with your computer Checkpoint Use with a system configura...

Page 24: ...le is connected to a USB hub or an add on USB board When you are using a custom built computer or one that you have modified When you are using a cable that is longer than 3 meters in length Please us...

Page 25: ...omputer and then turn on the computer 2 When Windows starts up insert the CD ROM supplied with the scanner into the CD ROM drive 3 Turn on the power to the scanner 4 The screen shown below is displaye...

Page 26: ...s displayed Click Browse and either select the DRIVER folder in the CD ROM drive or enter a CD ROM drive name and DRIVER using the keyboard Example For drive E enter E DRIVER 10 Click Next The wizard...

Page 27: ...ndows starts up insert the CD ROM supplied with the scanner into the CD ROM drive The Start screen opens automatically Click the Quit button to close the Start screen 3 Turn on the power to the scanne...

Page 28: ...xample For drive E enter E English DRIVER 7 Click Next The wizard will start searching for the driver 8 The screen shown below is displayed Read the explanation and make sure that you understand the c...

Page 29: ...een 5 When this screen is displayed select the option Search for a suitable driver for my device recommended and then click Next to display the Locate Driver Files screen 6 When this screen is display...

Page 30: ...is displayed Read the explanation and make sure that you understand the contents To continue the installation click Yes 10 The screen shown below is displayed when the wizard has finished installing...

Page 31: ...ws Vista 1 Launch the Control Panel using the Start menu on the Windows desktop 2 Click Hardware and Sound to display the screen shown below 3 Click Scanners and Cameras to display the screen shown be...

Page 32: ...art menu on the Windows desktop 2 The screen shown below is displayed when you click on the Printers and Other Hardware icon 3 The screen shown below is displayed when you click on the Scanners and Ca...

Page 33: ...ows 2000 1 Launch the Control Panel using the Start menu on the Windows desktop 2 The screen shown below is displayed when you click on the Scanners and Cameras icon Check that Graphtec CSX300 09 is d...

Page 34: ...he scanner into the CD ROM drive 3 Select Run from the Start menu on the Windows desktop 4 Enter the CD ROM drive name and English OPS112 SETUP EXE as the name of the file that you wish to open Exampl...

Page 35: ...the combined thickness of both the document and carrier sheet does not exceed 1 6 mm Moreover documents of an uneven thickness cannot be scanned Note The carrier sheet alone is 0 2 mm thick Compatibl...

Page 36: ...ng table Top cover There are two document setting modes available set by the driver software The rollers start turning at a preset delay time after the document has been inserted so that they automati...

Page 37: ...cuments see Section 3 5 Using the Carrier Sheet for details Load the document in the center of the scanner as the document may be fed in at an angle and not scanned correctly if it is significantly of...

Page 38: ...ty has been selected 1 Start up the Scanning Master 21 OPS112 software that is provided with your scanner and then display the Scan screen 2 Select the Options tab and then move the Scan Speed slider...

Page 39: ...distance correction necessitates that you measure a vertical line drawn on the document before following the procedure described below 1 Choose a document that has one or more vertical lines drawn on...

Page 40: ...t cannot be properly advanced to the initial position of scanning because the target document is not flat or otherwise hard to load in the scanner Curled documents with a width that exceeds A2 size 42...

Page 41: ...roximately 47 degrees 3 When the top cover is fully open the fixing stay operates to hold the top cover in place Closing the top cover 1 Press the open cover down gently with both hands to close it 2...

Page 42: ...e them clean using a soft cloth that has been moistened with water or a neutral detergent diluted with water and firmly wrung out Feed rollers 4 Wipe the feed rollers once again using a soft dry cloth...

Page 43: ...een moistened with water or a neutral detergent diluted with water and firmly wrung out Document support rollers 4 Wipe the document support rollers once again using a soft dry cloth to remove all the...

Page 44: ...e them clean using a soft cloth that has been moistened with water or a neutral detergent diluted with water and firmly wrung out Gap rollers 4 Wipe the gap rollers once again using a soft dry cloth t...

Page 45: ...e them clean using a soft cloth that has been moistened with water or a neutral detergent diluted with water and firmly wrung out Push rollers 4 Wipe the push rollers once again using a soft dry cloth...

Page 46: ...p cover as described in Section 4 1 Opening and Closing the Top Cover Caution Take care not to get your fingers caught in the cover Do not use a commercial cleaner for office equipment a glass cleaner...

Page 47: ...ng and Closing the Top Cover 3 Wipe the two paper sensors or the five document size detection sensors using a cotton swab document size detection sensors Paper sensors 4 Close the top cover as describ...

Page 48: ...4 1 Opening and Closing the Top Cover 3 If the document is jammed at the front remove the document by pulling it forward 4 If the document is jammed at the rear remove it by pulling it out from the re...

Page 49: ...usage environment Monitor 1024 x 768 pixels High Color or better resolution Checkpoint A low resolution monitor will make it difficult to discern any problem areas Launching the Scanner Adjustment Pr...

Page 50: ...that requires servicing Handle the calibration sheet with care so that it does not get bent To prevent soiling store it in its special storage box The calibration sheet is a consumable item It cannot...

Page 51: ...in the Calibration screen 11 The mouse arrow cursor changes to a cross cursor when moved over the data Click the left mouse button with the mouse positioned over the streak data The selected area is s...

Page 52: ...ly Cause Is the scanner properly grounded Is the USB cable between the computer and the scanner working properly Is the USB cable compliant with the USB 2 0 interface that you are using Is an add on U...

Page 53: ...ee Section 4 1 Opening and Closing the Top Cover Cause The document is curled too thin or otherwise in a poor condition Dust has accumulated on the paper sensors The document to be scanned may be too...

Page 54: ...nsor 1 is the leftmost sensor in the driver software s display screens 5 9 Smudges not appearing in the original document appear in the scanned data 5 10 The color intensity of the image data differs...

Page 55: ...due to a scanner malfunction Note however that the vividness of the stripe and moir patterns can be lessened by changing the resolution Cause The scanner s image scanning quality has deteriorated Is...

Page 56: ...can be obtained from the store where you purchased your scanner or your nearest Graphtec representative Options Consumables Part no Item name IS0922 Carrier sheet A0 IS0908 Carrier sheet A1 IS0925 Ca...

Page 57: ...ed Length 999 99999m 1 The value range where scanning length in software Guaranteed scanning precision range 2 841 x 1189 mm Document thickness Up to 1 6 mm including the carrier sheet Optical resolut...

Page 58: ...A 3 Appendix C External Dimensions Unit mm Dimensional accuracy 5 mm 1070 1097 322 160...

Page 59: ...A 4 When the scanner is mounted on the stand Unit mm Dimensional accuracy 5 mm 972 1097 650 717 10...

Page 60: ...E EJECT key 1 2 EM CP A 1 ERROR LED 1 2 External dimensions A 3 F Feed rollers Cleaning 4 2 Front view 1 2 G Gap rollers Cleaning 4 4 H Handling documents according 3 4 I Image sensors Cleaning 4 6 In...

Page 61: ...2 15 Sensors Cleaning 4 7 Specifications A 2 ST0074 A 1 STOP key 1 3 System requirements 2 4 T Top cover 1 2 Top cover open levers 1 2 Top cover Opening and Closing 4 1 Transparent contact plates 4 6...

Page 62: ...The specifications etc in this manual are subject to change without notice CSX300 UM 151 February 20 2008 1st edition 01 GRAPHTEC CORPORATION...

Page 63: ...503 10 Shinano cho Totsuka ku Yokohama 244 8503 Japan Tel 81 045 825 6250 Fax 81 045 825 6396 Email info graphteccorp com Web www graphteccorp com Printed in Japan 641711330...

Reviews: