2.1 BOiLER tECHNiCaL Data
table 2-1:
Boiler technical data
Units
15/21
21/26
26/35
36/46
46/58
58/70
Water content
litre
13
13
19
21
50
50
gal
2.9
2.9
4.2
4.7
11
11
Weight (dry)*
kg
125
125
143
145
257
301
lb
276
276
315
320
567
664
Maximum heat output (Kerosene)
kW
21.5
26.3
35.4
46.0
58.0
70.0
Btu/h
73,400
89,800
120,000
157,000
197,900
238,840
Minimum flow rate (∆T=10°C)
l/h
1,780
2,200
2,980
4,000
5,200
6,000
Minimum flow rate (∆T=20°C)
l/h
890
1,100
1,490
2,000
2,600
3,000
Condensate connection
22 mm (only connection plastic pipe)
Flue diameter (conventional)
100 mm
100 mm
100 mm
100 mm
125 mm**
125 mm**
Waterside resistance ∆T=10°C
mbar
28.5
26.0
Waterside resistance ∆T=20°C
mbar
10
9.5
Maximum static head
m
28
Minimum circulating head
m
1
Boiler thermostat range
°C
50±5 to 75±4
Limit (safety) thermostat shut off temperature
°C
110 ± 3
Maximum hearth temperature
°C
Less than 50
Electricity supply
~230 1ph 50Hz 5A fused
Burner motor power
Watts
90
150
Absorbed motor power
kW
0.16
Starting current
Amps
4.2
6.4
Running current
Amps
0.85
1.2
Oil connection
¼ʺ BSP male (on end of flexible fuel hose)
Conventional flue draught
mbar
Minimum: 0.087 - Maximum: 0.37
in wg
Minimum: 0.035 - Maximum: 0.15
Maximum operating pressure - sealed/open system
bar
2.5
Maximum operating pressure - pressure relief valve
bar
2.5
Boiler type
ON/OFF
* Weight includes burner but excludes flue
** 125 mm diameter required for flexible flue liner (orange system). For rigid flue systems, e.g. green system, 100 mm diameter flue required. Refer to Section 9
for further details.
Section 2: technical Data
page 6
2 tECHNiCaL Data