section 13: Guarantee

Page 19

terms of manufacturer’s guarantee

• 

The Company shall mean Grant Engineering (UK) Limited.

• 

The fan convector must be installed by a competent person 

and in full accordance with the relevant Codes of Practice, 

Regulations and Legislation in force at the time of installation.

• 

The fan convector is guaranteed for 

five years

 from the 

date of installation

4

, providing that the fan convector was 

registered with the Company within thirty days of installation. 

Any work undertaken must be authorised by the Company 

and carried out by a competent service engineer.

• 

The fan convector is operated correctly, in accordance with 

the Installation and user instructions. 

• 

Grant Engineering (UK) Limited 

strongly recommends

 that 

a Grant Mag-One in-line magnetic filter/s (or equivalent

5

is fitted in the heating system pipework. This should be 

installed and regularly serviced in accordance with the filter 

manufacturer’s instructions. We reserve the right to ask for 

proof of installation – failure to provide this may result in the 

guarantee becoming invalid.

• 

Proof is provided that the system has been flushed or 

chemically cleaned where appropriate (refer to BS 7593) 

and that the required quantity of a suitable corrosion inhibitor 

added.

• 

Proof of annual heating system servicing (including the 

checking of any expansion vessels and pressure relief 

valves) must be provided if and when requested by the 

Company.

• 

This guarantee does not cover breakdowns caused by 

incorrect installation, neglect, misuse, accident or failure 

to operate the fan convector in accordance with the 

manufacturer’s installation and servicing instructions.

• 

The fan convector is registered with the Company within 

thirty days of installation. Failure to do so does not affect your 

statutory rights

1

.

• 

The balance of the guarantee is transferable. Grant 

Engineering (UK) Limited must be informed of the new 

owner’s details.

• 

The Company will endeavour to provide prompt service in 

the unlikely event of a problem occurring but cannot be held 

responsible for any consequential losses. 

• 

This guarantee applies to Grant Engineering (UK) Limited fan 

convectors purchased and installed on the UK mainland, Isle 

of Wight, Channel Islands and Scottish Isles only

2

. Provision 

of in-guarantee cover elsewhere in the UK is subject to 

agreement with the Company.

• 

All claims under this guarantee must be made to the 

Company prior to any work being undertaken. Invoices for 

call out/repair work by any third party will not be accepted 

unless previously authorised by the Company. 

• 

Proof of purchase and date of installation, commissioning 

and service documents must be provided on request.

• 

If a replacement fan convector is supplied under the 

guarantee (due to a manufacturing fault) the product 

guarantee continues from the installation date of the original 

fan convector and not from the installation date of the 

replacement.

• 

Breakdown/failure due to system water contamination will not 

be covered by this guarantee.

• 

The replacement of a fan convector under this guarantee 

does not include any consequential costs, such as the 

removal or replacement of kitchen units, etc.

• 

The fan convector must not be sited in a location where it 

may be subjected to frost.

Foot notes

1.  Your statutory rights entitle you to a one-year guarantee 

period only.

2.  The UK mainland consists of England, Scotland and Wales 

only. Please note that for the purposes of this definition, 

Northern Ireland is not considered part of the UK mainland.

3.  We recommend that your heating system is serviced every 

twelve months (even when the guarantee has expired) to 

prolong the lifespan and ensure it is operating safely and 

efficiently.

4.  The guarantee period will commence from the date of 

installation, unless the installation date is more than six 

months from the date of purchase, in which case the 

guarantee period will commence six months from the date of 

purchase.

5. 

As measured by gauss. The MagOne magnetic filter has a 

gauss measurement of 12,000.

Summary of Contents for Solo Compact

Page 1: ...UK DOC 0139 Rev 1 0 October 2018 Grant Solo Fan Convectors Installation and User Instructions ...

Page 2: ...tallation commissioning and servicing of the Grant Solo fan convectors After installion leave these instructions with the user User instructions to guide users in the operation of the fan convectors are given in Section X of these instructions Special Text Formats The following special text formats are used in these instructions for the purposes listed below WARNING Warning of possible human injur...

Page 3: ...edure 8 Solo Compact and Solo CompactMAX models 3 8 Installation procedure 9 Solo Hideaway model 4 Electrical 11 4 1 General 11 4 2 Electrical connections 11 Contents Page 3 5 COMMISSIONING 11 6 Fault finding 12 6 1 Initial checks 12 6 2 Fault diagnosis flow chart 13 7 Spares PARTS 14 7 1 Fan convector parts list 14 8 OPERATING INSTRUCTIONS 14 8 1 Mains ON OFF switch 14 8 2 Control panel 15 9 Clea...

Page 4: ...ase but is insulated from it providing a low casing surface temperature regardless of the water flow temperature The top grille prevents contact with the heat exchanger With the electrical supply to the Solo fan convector switched on when the water temperature sensor located in the heat exchanger detects that the water temperature entering the unit exceeds 29 C the unit will start The air temperat...

Page 5: ...eration After this period has elapsed the Solo unit automatically returns to the normal temperature control with the fan operating at either Low or High setting as dictated by the difference between the air temperature and the air temperature setting on the unit 1 3 CONTROL PANEL OVERVIEW Grant Solo fan convectors are supplied with a simple control panel Refer to Figure 1 3 and Section 8 2 control...

Page 6: ... power W 4 4 4 Sound pressure level at 1 metre ISO 3744 Low speed dB A 18 18 18 High speed dB A 22 23 22 Boost dB A 38 39 38 2 2 PERFORMANCE DATA Table 2 2 Heating capacity BS EN ISO 16430 on high low fan speed Mean water temperature Units Solo Compact Solo CompactMAX Solo Hideaway High Low High Low High Low 35 C W 314 247 604 470 314 247 40 C W 426 335 831 646 426 335 45 C W 542 426 1 071 832 542...

Page 7: ...t for sealed water systems Code of practice for domestic heating and hot water supply 3 3 Location Solo Compact and CompactMAX fan convectors should be positioned with the lower edge approximately 75 100mm above the skirting level The Solo Hideaway fan convectors are fitted into the plinth or baseboard of fixed units e g kitchen units Refer to Section 3 7 for dimension of the opening required The ...

Page 8: ... and return pipework Solo Hideaway The flow and return connections are located on the right hand side of the unit To allow the unit to be fully withdrawn from the plinth or base board in which it is fitted without having to disconnect it from the system two flexible hose connections supplied will be required for installation of the Grant Solo Hideaway fan convector These are long enough to allow t...

Page 9: ...Refer to Section 5 Commissioning 3 8 Installation procedure Solo Hideaway model Accurately mark and cut the opening required in the plinth or panel into which the Grant Solo Hideaway unit is to be fitted The bottom edge of the opening MUST be at least 12mm above the finished floor level Refer to Figure 2 7 for the dimensions of the opening Figure 3 5 Solo Hideaway cut out and fixings holes NOTE If...

Page 10: ...om the plinth baseboard when they are connected Connect the electrical supply to the Solo fan convector unit Refer to Section 4 Electrical NOTE Do NOT fit the Solo Hideaway unit into the opening until the system has been filled and the fan convector s vented When all the Solo fan convectors have been connected to the system pipework the system can be filled Once the system is filled open the HIGHE...

Page 11: ... the lower edge Switch on the electrical supply to the fan convector at the fused double pole switch Solo Hideaway The Solo Hideaway is supplied with a pre wired 1mm2 3 core cable 1 300mm long for connection to the electrical supply This can be connected directly to a fused double pole switch located under the kitchen unit Alternatively a 3 pin 13A plug fitted with a 3A fuse can be fitted to the c...

Page 12: ...erature correctly set on the control panel refer to Section 8 2 Set required air temperature using the ON OFF button on the control panel Is the required temperature setting indicator light flashing refer to Section 8 2 Set point temperature has not yet been reached Wait until indicator light stops flashing Low heat output from fan convector Is the water flow through the fan convector too low Chec...

Page 13: ... SP0012 Any lights illuminated on the control panel Replace power and control PCB SP0129 and user interface PCB SP0128 Boost light flashing 20 C indicator light 2 bars flashing Check fans are running heat is being emitted Check power on fan output blue wire on PCB 50V AC Replace transformer SP0012 Check hot water supply to Solo is above 29 C Is the heat source functioning correctly Fix issue with ...

Page 14: ...nits have a factory fitted double pole mains ON OFF switch Solo Compact and CompactMAX models This switch is located under the right hand end of the front casing Refer to Figure 10 1 Figure 8 1 Solo Compact and CompactMAX mains ON OFF switch underside of unit Solo Hideaway model This switch is located on the right hand side of the unit It should have been set to the ON position before being finall...

Page 15: ...will then stop heating until needed again NOTE It is NOT possible to adjust the temperature setting if the water flow temperature is at less than 29 C Alarm Light The Alarm light will flash if the water flow temperature is less than 29 C Boost Cool button Press this button momentarily whilst the Solo unit is operating and the normal Solo temperature control will be overridden for a period of 20 mi...

Page 16: ...00 4 5 2006 EN 61000 4 6 2009 EN 61000 4 11 2004 EN 62233 2008 I hereby declare that the equipment named above has been tested and found to comply with the relevant sections of the above referenced specifications The unit complies with all essential requirements of the Directives Responsible Person Neil Sawers Position Technical Manager Signature Date 5th October 2018 10 DECLARATION OF CONFORMITY ...

Page 17: ...ns For guidance on the disassembly of the fan convector refer to the information given in the Servicing section of these instructions Recycling Many of the materials used in Grant fan convectors can be recycled these are listed in the table below Component Material Chassis and casing Mild steel galvanised Heat exchanger Copper tubes Aluminium fins Front casing panel wall hung units Polycarbonate C...

Page 18: ...r to contact Grant Engineering UK Limited Service Department on 44 0 1380 736920 who will arrange for a competent service engineer to rectify the fault Remember before you contact Grant Engineering UK Limited Ensure the fan convector has been installed and commissioned by a competent person in accordance with the installation and user instructions Ensure there is an electrical supply the fan conve...

Page 19: ...r s details The Company will endeavour to provide prompt service in the unlikely event of a problem occurring but cannot be held responsible for any consequential losses This guarantee applies to Grant Engineering UK Limited fan convectors purchased and installed on the UK mainland Isle of Wight Channel Islands and Scottish Isles only2 Provision of in guarantee cover elsewhere in the UK is subject...

Page 20: ...Grant Engineering UK Limited Hopton House Hopton Industrial Estate Devizes Wiltshire SN10 2EU Tel 44 0 1380 736920 Fax 44 0 1380 736991 Email info grantuk com www grantuk com ...

Reviews: