Section 10: Side Pellet Store
Page 44
10.3.3 Side Pellet Store installation
Install the side pellet store using the following procedure:
1. Undo and remove the three screws along the top edge of the
left hand side panel of the side pellet store. Refer to Figure 10-5.
Keep these screws for re-fitting later.
Figure 10-5:
Removing the three screws from the side store
2. Remove the front panel from the side pellet store. Undo and
remove the four panel retaining screws at the top edge of the
front panel. Refer to Figure 10-6. Lift the front panel upwards and
off the side pellet store casing.
Figure 10-6:
Removing the four screws and front panel
3. Remove the centre section of the grille inside the side pellet
store. Undo the single fixing screw and lift the centre section
away from the surrounding part of the grille. Refer to Figure 10-7.
Figure 10-7:
Removing the single fixing screw and grille
4. Whilst firmly holding the end of the auger spiral in position, cut
and remove the packaging securing it to the side pellet store.
5.
the end of the auger spiral MUSt be FiRMLY held to prevent
it from springing out and possibly causing injury when the
packaging is cut and removed.
!
WaRninG
Slacken the clamp bolt on the auger pipe socket so that the
auger extension pipe can be fitted. Refer to Figure 10-8 for
location of auger pipe clamp bolt.
Figure 10-8:
Location of auger pipe clamp bolt
6. Manoeuvre the side pellet store into position alongside right hand
side of the boiler, carefully feeding the end of the auger spiral
through the hole in the diaphragm seal plate in the side of the
boiler pellet hopper.
7.
Leave a gap of approximately 10mm between the spacer
channel and the side of the boiler at this stage of the
installation.
nOtE
!
Lubricate the outer surface of the auger extension pipe (at the
unpainted end) with some silicone grease, washing up liquid or
similar.
8. Working from within the boiler hopper, locate the unpainted end
of the auger extension pipe over the end of the auger spiral.
9. Looking through the 10mm gap between the boiler and side
pellet store spacer channel, carefully push the end of the auger
extension pipe through the diaphragm seal and into the auger
pipe socket.
10. Ensure it is fully pushed in and then secure in place by tightening
the auger pipe clamp bolt.
11.
Do not over tighten the clamp bolt as this can distort the auger
extension pipe and prevent the auger spiral from rotating
freely.
nOtE
!
Now push the side pellet store into its final position with the left
side of the side pellet store hard up against the right hand side of
the boiler casing.
12. From inside the side pellet store enclosure; re-fit the two hex
head screws through the bottom left hand edge of the side pellet
Clamp bolt