Fire Bowls and Inserts Premium Line
Automated Operation
Page 15
Section 4. Burner Setup and Adjustment
4.1 Burner Setup
1. Turn the manual gas valve or key valve to the “Off” position.
2. Energize the 120 VAC coming into the control panel.
3. At each burner assembly, check that the spark electrode is arcing
from the pilot hood to the button. You should be able to hear and see
the electrode spark. If there is no spark, make sure that the burner
assembly is receiving 12VAC from the control panel.
4. Reposition the burner assembly so that it is sitting level in the bowl.
5. Open the manual gas valve or key valve.
6. Energize 120V to the control panel.
7. After all bowls have been lit, they can be adjusted for flame size.
IMPORTANT:
At this time, the corresponding fire bowl should ignite. If
the burner does not light, it may be a result of air in the
gas line. If this happens, carefully purge the air from the
gas line by disconnecting the gas hose from the burner
assembly. The end of the gas hose should be outside of the
bowl when purging air from the gas line.
WARNING
To avoid the risk of property damage and serious injury, including
death, when purging air from a propane system, be sure to disconnect
wires going to the burner assemblies (terminals X1/X2) located in
Grand Effects
®
control panel. There should be no power at the burner
assemblies when purging propane. The propane adder valve should
remain wired and energized when purging. After purging is complete,
make sure the area is vented and free from built-up gas.
Reinstall wires at X1/X2 terminals, thus providing power to burner
assemblies.