Page 6
Fire Bowls and Inserts Premium Line
Automated Operation
Additionally, Zodiac Pool Systems LLC, requires that as required by Article
680 of the NEC, the appliance be properly connected to an equipotential
bonding grid/loop that includes all electrical equipment in the system and
on the equipment pad. Bonding lugs must be connected with a solid copper
wire at least 8 AWG (6 AWG in Canada) or larger. Failure to do so may void
the Zodiac Pool Systems LLC warranty.
CAUTION
To prevent premature failure of the appliance resulting from stray
voltages and voltage differentials, the metal bowl and burner must be
bonded to other equipment which is part of the pool plumbing system
with a solid copper wire not smaller in diameter than 8 AWG (6 AWG in
Canada).
BONDING A METAL BOWL (COPPER OR ALUMINUM)
NOTE:
A bonding lug is not provided for the bowl. These steps only apply
to metal bowls.
1. Attach the mounting bracket to the surface/floor. See Figure 7.
2. Wrap with copper bonding wire around a securing bolt between
the clamp ring and washer. See Figure 1 for mounting bracket
components.
3. Slide the clamp ring onto the securing bolts of the mounting bracket.
The clamp ring, washer and nut are placed inside of the bowl to secure
the bowl and bonding wire to the mounting bracket.
Clamp Ring
Mounting
Bracket
Washer
Nut
Securing
Bolt
NOTE:
Wrap bonding wire around a securing
bolt between clamp ring and washer.
Clamp ring, washer and nut to be placed
inside bowl to anchor to mounting bracket.
Anchor Bolt
Hole (3)
Spacer
Figure 1. Mounting Bracket Components for Securing and
Bonding of Bowl