SUMMIT-MULTI – INSTALLATION/OPERATION MANUAL
5IM-OF-K6C0-01
Jun/11
18
Burner reset cuts out
No oil
Call oil supplier.
Frozen oil line
Call technician or oil supplier.
Dirty oil filter
Replace filter.
Dirty nozzle, smoky fire
Replace nozzle, adjust nozzle air.
Faulty oil pump
Have pump replaced, adjust burner air.
Faulty or dirty electrodes
Have technician clean or replace.
Flame blowing off of burner
On the Beckett burner have igniters wired for intermittent
ignition (run constantly with the motor).
Noisy operation
Loose blower wheel
Tighten wheel set screw or replace.
Damaged motor bearings
Replace blower motor.
Faulty oil pump
Repair or replace oil pump. Reset to correct pressure.
Air leak in oil line
Tighten all connections.
9.1 MAX/EVO LED INDICATORS
Refer to decal on inside of wiring box cover.
GREEN LED (Status)
Slow Green
Standby.
Fast Green
B1-B2 Energized.
Solid Green
System Fault.
In this case the Red LED will flash a number of times to indicate probable cause.
1. Disconnect power
2. Correct error
3. Re-connect power
RED (Diagnostic)
On Power Up of system, the Red LED will flash. If there is a problem detected the system will
try two times to diagnose and correct the problem (approx. 80 seconds). If problem persists
Red LED error code will flash.
RED 3 Flashes
Heat/Aux Sensor Trouble
a) Ensure sensor or Jumper Plug (9300i only) is fully plugged into connector.
b) Otherwise, Replace Sensor or Jumper Plug (9300i only).
RED 4 Flashes
B1 Output Trouble
a) Check for wiring error
b) Otherwise replace control
RED 5 Flashes
System Trouble
a) Replace control