SUMMIT-MULTI – INSTALLATION/OPERATION MANUAL
5IM-OF-K6C0-01
Jun/11
13
EVO
Model Burner
Input
Nozzle
Pump
Air
Setting
Turbulator
Output Blower
Motor
Heating CFM
USGPH
L/h
Btu/h
(psi)
Btu/h
Kw
(inches)
(hp)
K6C-G2-K163-F5
Beckett AFG F3
0.90
3.40 126,000
0.75
70B
150
0/10
-
109,000 32 GT 12-10 3/4 hp
1210*
Beckett AFG F6
1.02 3.85
142,800
0.85 70B
150
0.5/5
-
122,000 36
GT 12-10 3/4 hp
1360*
1.22 4.64
170,800
1.00
70B
150 1/5
- 143,000 42
1590*
1.35 5.10
189,000
1.20
70B
130 1/7
- 163,000 48
1810*
K6C-N2-K129-F5 Beckett
NX-LH
0.94 3.55
131,600
0.75 60A
160
2.2
-
115,000 34
GT 12-10 3/4 hp
1280*
1.06 4.00
148,400
0.85
60A
155 3.7
- 129,000 38
1440*
K6C-N3-K164-F5 Beckett
NX-LB
1.22 4.64
170,800
1.00 60B
150
2.5
-
149,000 44
GT 12-10 3/4 hp
1660*
1.35 5.10
189,000
1.10
60B
150 4.0
- 164,000 48
1820*
K6C-E3-K160-F5
Riello 40 F5
0.92 3.48
128,800 0.75
60W
150 3.2
1.0 107,000 31
GT 12-10 3/4 hp
1190*
1.04 3.94
145,600 0.85
60W
150 3.3
2.0 122,000 36
1355*
1.22 4.64
170,800 1.00
60W
150 3.4
2.5 143,000 42
1590*
1.35 5.10
189,000 1.10
60W
150 4.0
3.5 157,000 46
1740*
Direct Vent / Evacuation directe
K6C-V3-K145-F5
Riello 40 BF5**
0.92 3.48
128,800
0.75 70B
150
4.5
1.5
107,000 31
GT 12-10 3/4 hp
1190*
1.04 3.94
145,600 0.85
60W
150 5.0
2.0 122,000 36
1355*
1.22 4.64
170,800 1.00
60W
150 6.2
2.5 143,000 42
1590*
* Approximately 90 Btu/h CFM
**Cannot be used in conjunction with an air conditioning coil or any device that will increase
the static pressure.
MAX
Model Burner
Input
Nozzle
Pump
Air
Setting
Turbulator
Output Blower
Motor
Heating CFM
USGPH
L/h
Btu/h
(psi)
Btu/h
Kw
(inches)
(hp)
K6C-G2-K163-E5
Beckett AFT F3
0.90
3.40 126,000
0.75
70B
150
0/10
-
109,000 32 GT 12-10 3/4 hp
1210*
Beckett AFG F6
1.02 3.85
142,800
0.85 70B
150
0.5/5
-
122,000 36
GT 12-10 3/4 hp
1360*
1.22 4.64
170,800
1.00
70B
150 1/5
- 143,000 42
1590*
1.35 5.10
189,000
1.20
70B
130 1/7
- 163,000 48
1810*
K6C-N2-K129-E5 Beckett
NX-LH
0.94 3.55
131,600
0.75 60A
160
2.2
-
115,000 34
GT 12-10 3/4 hp
1280*
1.06 4.00
148,400
0.85
60A
155 3.7
- 129,000 38
1440*
K6C-N3-K164-E5 Beckett
NX-LB
1.22 4.64
170,800
1.00 60B
150
2.5
-
149,000 44
GT 12-10 3/4 hp
1660*
1.35 5.10
189,000
1.10
60B
150 4.0
- 164,000 48
1820*
K6C-E3-K160-E5
Riello 40 F5
0.92 3.48
128,800 0.75
60W
150 3.2
1.0 107,000 31
GT 1 2-
10
1 hp
1190*
1.04 3.94
145,600 0.85
60W
150 3.3
2.0 122,000 36
1355
1.22 4.64
170,800 1.00
60W
150 3.4
2.5 143,000 42
1590
1.35 5.10
189,000 1.10
60W
150 4.0
3.5 157,000 46
1740*
Direct Vent / Evacuation directe
K6C-V3-K145-E5
Riello 40 BF5**
0.92 3.48
128,800
0.75 70B
150
4.5
1.5
107,000 31
GT 12-10 1 hp
1190*
1.04 3.94
145,600 0.85
60W
150 5.0
2.0 122,000 36
1355*
1.22 4.64
170,800 1.00
60W
150 6.2
2.5 143,000 42
1590*
* Approximately 90 Btu/h CFM
**Cannot be used in conjunction with an air conditioning coil or any device that will increase
the static pressure.
Note: The turbulator & air settings found in this section should be used as a guide.