SUMMIT-MULTI – INSTALLATION/OPERATION MANUAL
5IM-OF-K6C0-01
Jun/11
16
CLEARANCE TO COMBUSTIBLES FOR HORIZONTAL POSITION
Top
6”
(152 mm)
Front 24”
(610
mm)
Rear*
6”
(152 mm)
Side
6”
(152 mm)
Side (access)
24”
(610 mm)
Side Duct
1”
(25 mm)
Flue Pipe
9”
(229 mm)
Floor Non-Combustible
* Rear breech requires rear access of 18” (457 mm).
DRAFT PRESSURE
(not applicable to Direct Vent)
Breech draft pressure
-0.03” wc
Over fire draft pressure -0.01”
wc
BURNER INSERTION
(overall)
Riello
2 1/2”
(63 mm)
Beckett AFG
2 1/2”
(63 mm)
Beckett NX
1 1/2”
(38 mm)
AIR/BLOWER DATA
External static - Non A/C
0.2” wc
External static - A/C
0.5” wc
Maximum air temperature rise
85°F
High limit, max. design outlet temp.
200°F
Thermostat anticipator
0.2 amps (
Classic Air
)
0.1 amps (
MAX/EVO
)
MOTOR/BLOWER
3/4 hp 4 Speed/GT 12-10
1 hp ECM/GT12-10
FAN/HIGH LIMIT CONTROL
Classic Air
Honeywell Fan Center & Thermo-Disk
EVO
9200i Control Board (Variable or Non-Variable)
MAX
9300i Control Board (Variable)
DIMENSIONS
Depth
26 5/8”
(676 mm)
Height
51 1/4”
(1302 mm)
Width
22 5/16”
(567 mm)
PLENUM DIMENSIONS
(W x D)
Warm air supply
21” x 23 1/2”
(533 x 597 mm)
Cold air return
18 5/8” x 23 1/2”
(473 x 597 mm)
A/C COIL LOCATION
Minimum height above the heat exchanger
10” (254 mm)
*See A/C coil Manufactures Requirements