Displaying the latest defrosting cycles:
Select
Set Up 01
. Then push
to see the recent 32 defrost cycles and the relating data. The display shows
starting time and date, duration in minutes, and the defrost numbers in order from D01 to D32.
The M indicates the type of defrost start:
M=01 Defrost started manually during storage.
M=02 Periodic defrost during storage.
M=03 Defrost started on the blast chilling starting.
Scrolling through the defrost cycles can be done by using the up/down keys
.
If there are no recorded data, the display shows:
No Date
.
Push
MENU
to return to the main menu.
Displaying door openings:
Select
Set Up 02
. Push
to display the recent door openings.The controller allows recording up to 31 days.
Use the up/down keys
to select the other dates of door opening.
Push
MENU
to return to the main menu.
Changing parameters:
Select
Set Up 03
. Then push
to enter setting of the parameters.
Use the up/down keys
to scroll the various parameters.
To change a parameter, push
, and then use the up/down keys
to change the value.
Push
again to confirm the new value. Push
MENU
to return to the menu.
D09
22Min
M=03
S 11:44 10/06/05
05/11
01h34 min
long:01
tot: 03
Date
Total time – door openings
Total number of door
openings
Number of door openings
exceeding the time setting
for door alarm.
A03 = -10°C
Low alarm
Parameter name
and value
Description