Error codes

 

 
If the cabinet has a defect or operating troubles occur, the display will typically show an error code. 
 
In the table below you can get information about the error and how to correct it. 
 

Error code 
 

Cause 

How to correct the error 

ALL High Press 

High pressure switch activated. 

• The blast chiller is located too close to the 
wall behind. 
• Ask Gram Service department for skilled 
assistance. 

ALL Room Sensor 

Room sensor defect. 

• Qualified technician required. 
Replacement of room sensor. 

ALL Evap Sensor 

Evaporator sensor defect. 

• The problem may be a frosted evaporator. 
• Ask Gram Service department for skilled 
assistance. 

ALL Cond Sensor 

Condenser sensor defect. 
(this only concerns cabinets with built-
in compressors) 

• Qualified technician required 
• Replacement of the condenser sensor. 

ALL Probe 

Probe sensor defect. 

• Qualified technician required. 
• Replacement of the probe sensor. 

ALL Insert Probe 

Probe sensor not correctly inserted in 
the food item, although a probe sensor 
cycle is running. The cycle will 
automatically change to a 
timecontrolled cycle. 

• Insert probe or ignore the error code. 
• 

IMPORTANT

: If the probe is not used at 

Quickguide programmes, it must be heated 
before restart of the programme to avoid that 
the process starts in storing cycle (cons.) 

High T Room 

The room temperature is / has been 
higher than the set point, plus 10°C (in 
storing programme)  
Example:  
The set point is set to +2°C. The upper 
alarm threshold will in this case be 
+12°C. 

• Qualified technician required. 

Low T Room 

The room temperature is / has 
been below the set point, less 10°C 
(storing cycle). 
Example: 
The set point has been set to +2°C. 
The lower alarm threshold will then be 
-8°C. 

• Qualified technician required. 

ALL BlackOut 

The power supply has been 
disconnected. 

• When power is restored, you can see under 

ALARM 

how long this blackout has lasted, 

and what the maximum temperature has been. 

ALL Door Open 

Door is open. 
Door microswitch defect. 

• Close the door. 
• If the error code is still shown in the display 
after the door has been closed, a qualified 
technician is required. 

 

 

Summary of Contents for 860120020

Page 1: ...1 KPS cabinets...

Page 2: ...JP 000 Contents Starting up 3 Language date and time 4 Pre cooling 5 Short cut keys 6 Working cycles 6 Saving of user programmes 8 IFR cycle 9 Use of recommended programmes 10 Use of own programmes 11...

Page 3: ...the cabinet to the main power If the display does not turn on when power is connected press to turn on the cabinet Then press twice to display Use the keys to select the desired menu Language date an...

Page 4: ...e default language is English Therefore the display language is English unless this is changed Date and time are set afterwards Press and then until the display shows Press to access the menu The disp...

Page 5: ...ce to return to the main menu The main menu display now shows Pre cooling To enable an effective chill freeze cycle it is advisable to run a pre cooling cycle of the cabinet prior to selecting any cyc...

Page 6: ...t freezing cycle Quick negative chill key Activates a blast chill cycle Quick soft positive chill key Activates a pre cooling cycle Also when pressed once it will repeat the latest cycle The short cut...

Page 7: ...start menu see diagram Regarding core at level 2 This cycle is with the core probe and continues until the core temperature has reached 3 C when running a soft or hard positive cycle and 18 C when ru...

Page 8: ...the programme do this before running the programme see next section Press to start the cycle Saving of user programmes User programmes can be saved After programming a user cycle it can be saved Do a...

Page 9: ...lly adapts the cycle to the food item s characteristics IFR minimises frost on the food surface Insert the probe correctly into the food item and activate an IFR cycle The temperatures are then monito...

Page 10: ...to start an IFR cycle Simply press for 5 secs and the cycle will start immediately Use of recommended programmes It is possible to choose between recommended programmes which are pre set programmes t...

Page 11: ...2 C 90 min 23 PIE Time No 2 C 90 min 24 STEW Time No 2 C 90 min 25 FISH Time Yes 2 C 90 min 26 POULTRY Time Yes 2 C 90 min 27 VEGETABLES Time No 2 C 90 min 28 FREEZING TEMP Core probe Yes 22 C 240 min...

Page 12: ...eted Date Name Date Name Rev no Date Name 30 09 11 JP 000 Pre cooling It is recommended to pre cool the cabinet prior to any cooling or freezing prozess Press to select the desired menu Use until the...

Page 13: ...binet can run a storing cycle for a short period Press to select the desired menu Use and until the display shows Press to confirm your choice To set a positive storing temperature press until the dis...

Page 14: ...eted Date Name Date Name Rev no Date Name 30 09 11 JP 000 The display shows Use and to change fan speed Press to confirm your choice The display shows Press to start the storing cycle We recommend tha...

Page 15: ...d technician required Replacement of the probe sensor ALL Insert Probe Probe sensor not correctly inserted in the food item although a probe sensor cycle is running The cycle will automatically change...

Page 16: ...9 11 JP 000 Sterilization programme This function is only possible if the cabinet is equipped with sterilisation equipment UV lamp optional equipment Press to select the sterilisation programme and us...

Page 17: ...ter and use and until the display shows Press and the display shows Press to print the memorised data Subsequently the data will be printed during the following cycles Press and select Ok and all memo...

Page 18: ...ion 765041466 Description Operation and servicemanual Gram Process KPS Compiled Latest revision Deleted Date Name Date Name Rev no Date Name 30 09 11 JP 000 Put the roll of paper into its box Close th...

Page 19: ...gain access to the mode for displaying alarms press and use and to display Then press to see the latest alarms If no alarms are memorized the display shows If alarms are memorised the display shows e...

Page 20: ...room sensor error Room Sensor Error type in this example a room sensor error S Alarm start E Alarm stop Present Alarm is still in progress See page 15 for an overview of error codes cause and how to r...

Page 21: ...the data Press several times to exit Display Description Room and probe temperature values Internal surface temperature of food item External temperature around the food item Evaporator and condenser...

Page 22: ...he service technician Therefore the area is protected with a password Changes in the parameters will directly influence the operation and functions of the cabinet Press to select the desired menu Use...

Page 23: ...20 C 30 C 30 C P05 Process duration 90 min 0 min 900 min P06 Hard phase duration expressed in relative to P05 60 0 100 P07 Room temperature setpoint storing 2 C 30 C 30 C Negative quick cooling N01 Ro...

Page 24: ...g time 1 min 0 min 90 min S07 Compressor activation delay with hot gas defrost 0 sec 0 sec 600 sec S08 First defrost activation time from storing start 0 excluded 0 0 90 min S09 Ignores compressor pro...

Page 25: ...ion hysteresis 2 C 0 C 20 C F02 Condenser fans activation hysteresis 2 C 0 C 20 C F03 Evaporator fans activation setpoint 5 C 50 C 50 C F04 Condenser fans activation setpoint 15 C 50 C 50 C F05 Evapor...

Page 26: ...tpoint in the event of automatic switch to time or temperature mode 7 C 50 C 99 C B19 Max duration possible for IFR process 999 min 1 min 999 min B20 Surface temperature safety value determining the e...

Page 27: ...v no Date Name 30 09 11 JP 000 Reset memory This function cancels the memorised data but not the memorised user s programmes Press to select the desired menu Use the keys to display Press to confirm y...

Page 28: ...hole memory Press several times to exit Restore This function restores the original parameters ATTENTION should you use the device with the RESTORE option available on the card please apply to the man...

Page 29: ...nual Gram Process KPS Compiled Latest revision Deleted Date Name Date Name Rev no Date Name 30 09 11 JP 000 The display shows Use the keys to display Press to gain access to cancelling the stored data...

Reviews: