Error message
Error message description
Is displayed...
Action
Confirmation/Reset
E.70
Low Power Supply Voltage Error
The Power Supply Voltage of the system is
below 20VDC. This may cause the pump motor
to lose its torque for driving the pump head
properly and the applicator to maintain its set
temperature at high feeding quantities.
As long as the Error is
persistent
Machine disabled
No confirmation
possible
E.71
High Power Supply Voltage Error
The Power Supply Voltage of the system is
above 30VDC. Further increase of the Power
Supply Voltage may cause the device to be
damaged.
As long as the Error is
persistent
Machine disabled
No confirmation
possible
Status LED
Status LED description
Is ON...
RED
Fluid Motion Controller and Hal Sensor
DIGIT Button pressed indicator
-
As long as a Fluid Motion
Controller Error (E.40
–
E.44) is persistent
-
While a Hal Sensor DIGIT
Button is pressed
YELLOW
Hot Application Error indicator
-
As long as a Hot
Applicator Error (E.10
–
E.11) is persistent
GREEN
Pump Run indicator
-
While the Pump Motor is
running
Status LED Description Single Lub 2
Instruction Manual GRAF SINGLE LUB 2 / Version 4.0
–
05.2020
21