I/O
u.05
Acceleration
time at
pump start
□
MODE
u.00..u.30
This setting determines the acceleration
time from when the pump is started until
the feed quantity set has been reached.
With setting u.00, the pump feeds
immediately with the specified feeding
quantity.
Default-value: u.05
The value 05, for example, means that the
adjusted output is reached within 5
seconds after starting the pump. This value
should be chosen according to the
acceleration of the winding machine. The
minimum value is 0, the maximum value is
30 seconds.
□
I/O
d.01
Deceleration
time at
pump stop
d.00..d.30
This setting determines the deceleration
time from when the pump is stopped until
the feed quantity is zero. With setting d.00
the pump stops immediately after
switching off.
Default-value: d.01
NOTE:
deceleration begins at the moment
the pump is switched off.
END OF SETTINGS
Menu EXITS to set metering quantity
Instruction Manual GRAF SINGLE LUB 2 / Version 4.0
–