I/O
CL.0
Clock
operating
mode
determines
the clock
operating
mode.
□
MODE
CL.0 ..CL.8
CL.0: No Clock Input
CL.1: With acceleration ramp
(ramp reset on every pump restart)
CL.2: With acceleration ramp
(ramp reset only on reset input
signal)
CL.3: Clock operating mode
CL.4: Clock operation mode with
clock-controlled release
CL.5: Clock-controlled release only
CL.6: Clock operation mode with
clock-drop-detection
CL.7: Clock operation mode with
clock-controlled release and
clock-drop-detection
CL.8: Clock-controlled release only with
clock-drop-detection
Default-value: CL.0
** Acceleration ramp only active with
corresponding setting
□
I/O
C.10
Clock input
rate setting
determines
the clock
input rate in
pulses/ meter
□
MODE
C.01 ..C.50
When the system is used on a winding
machine with a non-constant thread speed,
the system must be connected to a speed
signal equivalent to the thread speed. The
C.-Value must be equal to the count of
pulses per meter of thread, delivered by the
thread-reel on the
meter-counter. This menu item is only
activated if the setting CL.3 to CL.8 was
selected in the clock operating mode.
Default-value: C.10
The input signal is connected to the grey
cable (see Schematic diagram chapter 7).