I/O
A.02
Applicator
setting
determines
type of
applicator
used.
□
MODE
A.00..A.03
A.00: Cold applicator, no check of
temperature
A.01: Cold applicator with Clean-Start
(1.5 rotations).
A.02: Hot applicator
A.03: Hot applicator with automatic
temperature reduction at standstill
* Temperature display only active with
activated hot applicator
□
I/O
Ad.0
automatic
temperature
reduction
determines
delay of
temperature
decrease
□
MODE
Ad.0..Ad.6
If A.03 (hot applicator with automatic
temperature reduction at standstill) was
selected in the applicator setting, this menu
item is activated and the time delay of the
automatic temperature reduction when the
pump is at a standstill can be specified in 6
steps.
Ad.0: No delay (immediate temperature
reduction at standstill)
Ad.1: temperature reduction 10 seconds after
standstill
Ad.2: temperature reduction 30 seconds after
standstill
Ad.3: temperature reduction 1 minute after
standstill
Ad.4: temperature reduction 2 minutes after
standstill
Ad.5: temperature reduction 5 minutes after
standstill
Ad.6: temperature reduction 10 minutes after
standstill
□
I/O
AtP.
°60
Applicator
temperature
determines
temperature
of applicator
□
MODE
°20 ..°80
At this menu point the control temperature of
the Hot Applicator (if connected and with
A.02 / A.03 activated) is set. The temperature
value between 20 and 80 degrees is entered
in ° C. At this menu point the display shows
alter ately AtP. a d the alue set of
temperature.
Default-value: °60
Instruction Manual GRAF SINGLE LUB 2 / Version 4.0
–
05.2020