background image

Parts 

60

313289W

XM_ L _ _ Parts Varying by Top-Level Part Number

See 

Models

, page 9, for components equipped on your system.

Models

Part

Description

For additional information, refer to:

XM1L00

XM1A00

SYSTEM, XM50, WP

XM1_ _ _ Models

 page 78

XM1L10

XM1A00

SYSTEM, XM50, WP, 10

XM1_ _ _ Models

 page 78

- - -

HOPPER, 10 gallon, ss

10-Gallon Hopper Parts

, page 92

XM3L00

XM3A00

SYSTEM, XM70, BF, WP

XM3_ _ _ Models

 page 79

XM3L10

XM3A00

SYSTEM, XM70, BF, WP

XM3_ _ _ Models

 page 79

- - - 

HOPPER, 10 gallon, ss

10-Gallon Hopper Parts

, page 92

XM5L00

XM5A00

SYSTEM, XM50, BF, R, WP

XM5_ _ _ Models

 page 80

XM5L10

XM5A00

SYSTEM, XM50, BF, R, WP

XM5_ _ _ Models

 page 80

- - - 

HOPPER, 10 gallon, ss

10-Gallon Hopper Parts

, page 92

XM7L00

XM7A00

SYSTEM, XM70, R, WP

XM7_ _ _ Models

 page 81

XM7L10

XM7A00

SYSTEM, XM70, R, WP

XM7_ _ _ Models

 page 81

- - -

HOPPER, 10 gallon, ss

10-Gallon Hopper Parts

, page 92

Summary of Contents for XM Series

Page 1: ...cations For professional use only Important Safety Instructions Read all warnings and instructions in this manual and all related manuals before using the equipment Save these instruc tions 313289W EN WL D See page and 11 for Approvals and page 15 for Overview information See Technical Specifications on page 104 for maximum working pressure ...

Page 2: ...atic XM Sprayer with Wall Power page 1 51 Detailed Electrical Schematic XM Sprayer with Wall Power page 2 52 Junction Box Wiring Schematics 53 Non Hazardous Location 240V and 480V Viscon Water Heated Hose 53 Non Hazardous Location 240V Electric Heated Hose 54 Non Hazardous Location 480V Electric Heated Hose 55 Hazardous Location 240V and 480V Viscon Water Heated Hose 56 Hazardous Location 240V Ele...

Page 3: ...teel Hopper Installation Kit Instructions Parts 406739 Desiccant Kit Instructions Parts 406690 Caster Kit Instructions Parts 406691 Hose Rack Kit Instructions Parts 313258 Electric Heated Hose Power Supply Kit Instructions Parts 313259 Hopper or Hose Heat Circulation Kit Instructions Parts 312770 Lower Strainer and Valve Kit Instructions Parts 312749 XM Mix Manifold Kit Instructions Parts 313293 A...

Page 4: ...t can cause static sparking To help prevent fire and explosion Use equipment only in well ventilated area Eliminate all ignition sources such as pilot lights cigarettes portable electric lamps and plastic drop cloths potential static sparking Ground all equipment in the work area See Grounding instructions Never spray or flush solvent at high pressure Keep work area free of debris including solven...

Page 5: ...ss unit is removed from the hazardous explosive atmosphere location If explosion proof heaters are used ensure wiring wiring connections switches and electrical distribution panel all meet flame proof explosion proof requirements SKIN INJECTION HAZARD High pressure fluid from gun hose leaks or ruptured components will pierce skin This may look like just a cut but it is a serious injury that can re...

Page 6: ... equipment Keep children and animals away from work area Comply with all applicable safety regulations TOXIC FLUID OR FUMES HAZARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin inhaled or swallowed Read Safety Data Sheets SDSs for handling instructions and to know the specific hazards of the fluids you are using including the effects of long term exposu...

Page 7: ...maintained and adjusted according to instructions in the manual To prevent inhalation of isocyanate mists vapors and atomized particulates everyone in the work area must wear appropriate respiratory protection Always wear a properly fitting respirator which may include a supplied air respirator Ventilate the work area according to instructions in the fluid manufacturer s SDSs Avoid all skin contac...

Page 8: ... reservoir if installed filled with appropriate lubricant The lubricant creates a barrier between the ISO and the atmosphere Use only moisture proof hoses compatible with ISO Never use reclaimed solvents which may contain moisture Always keep solvent containers closed when not in use Always lubricate threaded parts with an appropriate lubricant when reassembling NOTICE Changing the material types ...

Page 9: ...ponents No Top Level Sprayer approval individual component approvals listed in Approvals page 11 Uses Explosion Proof Viscon High Flow HF Fluid Heaters XM sprayers are not approved for use in hazardous locations unless the base model all accessories all kits and all wiring meet local state and national codes First Two Digits Third Digit Fourth Digit Fifth Digit Sixth Digit Model Pump Set psi Remot...

Page 10: ...eaters First Two Digits Third Digit Fourth Digit Fifth Digit Sixth Digit Model Pump Set psi Remote Manifold Control Power Viscon HF Fluid Heaters Junction Box Feed System Heated Hose Wall Power XM_A00 Intrinsically Safe Alternator XM_D00 240V 480V 240V 480V Feed XM 1 XM50 5200 L 0 None 0 None 3 XM70 6300 M 1 10 Gallon Stainless Steel W Water 5 XM50 5200 H 2 25 Gallon Heated Skid E Electric 7 XM70 ...

Page 11: ...C to 54 C FM09ATEX0015X Ex i Class I Div 1 Group D T3 Ta 0 C to 54 C II 2 G Ex db ib pxb IIA T3 Tamb 0 C to 54 C FM09ATEX0015X Ex i Class I Div 1 Group D T3 Ta 0 C to 54 C II 2 G System is intended for hazardous locations with the classification of Class 1 Division 1 Group D T3 0 C to 54 C System is intended for hazardous locations with the classification of Class 1 Division 1 Group D T3 0 C to 54...

Page 12: ...oup D T3 Ta 0 C to 54 C II 2 G Viscon Fluid Heater North American Location European Atmosphere Approvals Component Description Non Hazardous Hazardous Class 1 Division 1 Non Hazardous Hazardous 26C476 480V HF Ex 24W248 240V HF Ex 24P016 240V HF Ordinary 26C475 480V HF Ordinary 9902471 Class 1 Division 1 Groups C D T3 Ta 20 C to 60 C Certificate No 18 KA4B0 0072X IECEx Ratings EX db IIB T4 Gb IECEx...

Page 13: ... 0 UL 60079 25 26C906 480V Explosion Proof Junction Box Electric Hose Heat 26C581 240V Explosion Proof Junction Box 26C905 240V Explosion Proof Junction Box Electric Hose Heat Ordinary Location Electrical Enclosure 26C582 480V Junction Box 26C904 480V Junction Box Electric Hose Heat 26C580 240V Junction Box 26C899 240V Junction Box Electric Hose Heat Class 1 Division 1 Groups B C D UL 1203 CSA C22...

Page 14: ...Immersion Heaters 480V 25N577 Immersion Heaters 240V 25N584 5 1 Monark Pump 25N588 Xtreme Duty Hopper Agitator Heated Hose North American Location Category European Atmosphere Category Approvals Component Description Ordinary Hazardous Class 1 Division 1 Ordinary Hazardous See your water heated hose manual for complete list of part numbers Water Jacketed See your electric heated hose manual for co...

Page 15: ...heck electrical resistance of hose regularly If total resistance to ground exceeds 29 megaohms replace hose immediately Spray gun Ground through connection to a properly grounded fluid hose and pump Solvent pails Follow your local code Use only conductive metal pails placed on a grounded surface Do not place the pail on a non conductive surface such as paper or cardboard which interrupts grounding...

Page 16: ...Lift Using a Hoist Sprayer can also be lifted and moved using a hoist Connect a bridle swing hooking an end to each of the air motor lift rings Hook the center ring to a hoist See the following figure Carefully lift the sprayer make sure it balances evenly Do not lift with 25 gallon hoppers attached to the unit Follow instructions to avoid serious injury or damage to equipment Never lift with the ...

Page 17: ...e in material hoses 7 Engage trigger lock 8 Close mix manifold valves AH AJ This equipment stays pressurized until pressure is manually relieved To help prevent serious injury from pressurized fluid such as skin injection splashing fluid and moving parts follow this Pressure Relief Procedure when you stop spraying and before cleaning checking or servicing the equipment TI1949a WL D NOTICE To preve...

Page 18: ... lid with a hole in it to dispense through Be careful to keep fingers away from the front of the gun Trigger gun until clean solvent appears 6 Close solvent pump air valve CB 7 Hold a metal part of the gun against a grounded metal pail and trigger the gun to relive pressure Close the solvent flush valve AK after relieving the pressure 8 Engage trigger lock 9 Disassemble and clean spray tip with so...

Page 19: ...o separate grounded fluid containers 6 Open the recirculation valves AC AD 7 Open the feed pump air valve EM and begin to pump material out of the hopper The feed pump may stall To avoid fire and explosion always ground equipment and waste container To avoid static sparking and injury from splashing always flush at the lowest possible pressure Hot solvent may ignite To avoid fire and explosion Flu...

Page 20: ...t of the system press 12 Place a small pail under the hopper and open the material drain EH to fully drain the spray material 13 Close the material drain EH and fill the hopper with solvent 14 Return the circulation lines U to their respective hoppers 15 Open on the agitator air valve EP and feed pump air valve EM 16 Select pumps to recirculate by pressing to scroll through or 17 Turn on the main ...

Page 21: ... Drain the material by moving circulation lines to a waste container or using the material drain EH 19 Repeat steps 13 18 Change the flushing solvent until it runs clean 20 Turn off the main air shutoff valve CA CD CA CA ...

Page 22: ...e and Spray Gun procedure on page 18 Engage trigger lock Turn main pump air regulator CD fully counter clockwise to shut off NOTE When flushing coating materials remove pump fluid filters if installed and soak in solvent to decrease cleaning time If flushing a new system leave filters in place Proceed with Step 2 2 Move circulation return lines to separate fluid containers to pump remaining fluid ...

Page 23: ...ack to hoppers Continue recirculating until system is thoroughly flushed 9 Close recirculation valves AC AD and open mix manifold valves AH AJ Dispense fresh solvent through mix manifold valves and out gun 10 Close mix manifold valves AH AJ 11 Slowly open sampling valves AE AF to flush solvent through until clean Close sampling valves Press 12 Follow the Park Fluid Pump Rods procedure page 24 13 R...

Page 24: ...o entire system Shutdown Entire System Follow this procedure prior to servicing equipment or shutdown 1 Follow Flush Mixed Manifold Hose and Spray Gun page 18 2 Engage trigger lock turn off air regulator and close main air shutoff valve Remove spray tip 3 If the unit will be shut down for more than 24 hours Perform the Park Fluid Pump Rods procedure Cap fluid outlets to keep solvent in the lines F...

Page 25: ...pment to cool 4 Flush mixed material Follow the Flush Mixed Manifold Hose and Spray Gun procedure on page 18 5 Relieve pressure Follow the Pressure Relief Procedure on page 17 6 Shutdown sprayer and turn off all power Follow the Park Fluid Pump Rods procedure on page 24 7 Clean external surfaces using only a rag soaked in solvent that is compatible with the spray material and the surfaces being cl...

Page 26: ... equipment Problem Cause Solution Display not lit on system with alternator power supply No electric power Air valve not turned on Turn on main air valve to system Air supply pressure too low Increase pressure to 30 psi 0 21 MPa 2 1 bar or greater Air supply filters plugged Inlet manifold filter 604 or air regulator 344 filter plugged Clean filter bowls replace filter elements Page 29 Turbine air ...

Page 27: ...ot valve s to motor stuck Replace valve s Page 40 Metering valve s not opening Service or replace valve s Page 40 Air motor stalled See air motor manual Pump Test completes without error but A or B component has more than 750cc of fluid in beaker Incorrect pumps were selected in System Setup screens See Appendix A in your XM sprayer operation manual Air is trapped in fluid due to excessive agitati...

Page 28: ... it was added to sprayer Mix material thoroughly Not using enough integration hose Add more integration hose Select fast dosing in setup Poor spray pattern Fluid pressure too low Increase pump pressure Fluid temperature too low Increase fluid temperature Spay tip dirty or worn Relieve pressure Clean or replace tip Follow gun manual instructions Fluid A and B fitters plugged Clean filters See pump ...

Page 29: ...ter 1 Close main air shutoff valve on air supply line and main air valve E on unit Depressurize air line 2 Unscrew filter bowl D from main air valve E 3 Remove and replace filter element 601a See Air Inlet Manifold 26C689 Parts page 88 4 Reassemble filter bowl 5 Replace front and rear shrouds 12 13 using four nuts 14 To avoid injury due to unexpected machine operation initiated by a remote control...

Page 30: ...wo nuts on left side of panel tight Open front panel of control box 11 4 Disconnect solenoid cable connectors 242 from solenoids 5 Disconnect air tubing from solenoid manifold block 209 NOTE If your sprayer is an intrinsically safe model you will need to remove the alternator air regulator from the solenoid module See Replace Alternator Regulator page 37 for removal instructions 6 Remove two screw...

Page 31: ...t settings Record all settings and user preferences before the upgrade for ease of restoring them following the upgrade The latest software version for each system can be found at Tech Support at www graco com Replace USB Module 1 Remove shroud See Remove Shroud 2 Disconnect power 3 Remove four nuts 4 leave two nuts on left side of panel tight Open front panel of control box 11 4 Disconnect CAN ca...

Page 32: ... for each system can be found at Tech Support at www graco com Replace Fluid Control Module FCM NOTE The USB module does not need to be removed prior to replacing the FCM 1 Remove shroud See Remove Shroud 2 Disconnect power 3 Remove four nuts 4 leave two nuts on left side of panel tight Open front panel of control box 11 4 Remove all cables from FCM 218 Take note of cable locations 5 Loosen four m...

Page 33: ...le may be reset to factory default settings Record all settings and user preferences before the upgrade for ease of restoring them following the upgrade The latest software version for each system can be found at Tech Support at www graco com 1 Remove shroud See Remove Shroud 2 Disconnect power 3 Remove four nuts 4 leave two nuts on left side of panel tight Open front panel of control box 11 4 Rem...

Page 34: ...uts 4 leave two nuts on left side of panel tight Open front panel of control box 11 4 Disconnect CAN cable from display module 5 Remove four screws 204b from rear display panel 204c while holding front display panel 204d in place NOTE To ease removal process use clear tape to hold front display panel 204d in place 6 Remove rear display panel 204c and disconnect display cable and key switch cable 2...

Page 35: ...are 33 16 Replace shroud 17 Configure system settings as they were set on old display See your XM sprayer operation manual for instructions Replace Front Panel See Replace Display page 34 for instructions Wall Power Supply Control Components Replace Power Supply Module 1 Remove shroud See Remove Shroud 2 Disconnect main power 3 Remove four nuts 4 leave two nuts on left side of panel tight Open fro...

Page 36: ...ne 7 Remove four screws 263 from mounting to remove alternator from control box 8 Remove seven screws 708 to separate alternator housings 9 Replace turbine 704 if necessary Lightly lubricate turbine o ring to ease alternator housing reassembly 10 Replace gasket 702 and or circuit board assembly 705 if damaged 11 Follow steps in reverse order to reassemble alternator regulator assembly and to recon...

Page 37: ...om alternator assembly 265 5 Loosen air regulator swivel fitting 276 and remove from solenoid module 209 6 Repair or replace alternator regulator parts as necessary See Alternator Assembly page 84 for repair parts Replace air regulator swivel fitting 276 7 Set regulator to 18 1 psi 12 6 10 kPa 1 26 0 07 bar 8 Start machine Check voltage on the alarm information screen Voltage should be between 10 ...

Page 38: ...r 322 6 Remove regulator assembly and replace with new See Air Controls Module 26C688 Parts page 86 7 Follow steps in reverse order to reassemble Replace System Air Regulator 1 Remove shroud See Remove Shroud page 30 2 Disconnect air motor air lines and system air line 3 Remove four nuts 7 from front of air control bracket 301 4 Pull out assembly 5 Remove regulator nut 326 and disconnect system ai...

Page 39: ...Repair 313289W 39 FIG 1 Air Controls WL D ...

Page 40: ...ur dosing valve manual service and repair instructions 7 Follow steps in reverse order to reassemble dosing valve assembly Mix Manifold Assembly 1 Follow Pressure Relief Procedure page 17 2 Disconnect fluid line and solvent lines from mix manifold assembly 3 Loosen four bolts securing mix manifold 508 to bracket 4 Unscrew dosing valve housing seats from adapters on mix manifold 5 Remove four bolts...

Page 41: ...id pressure sensor and reconnect pressure sensor to FCM Temperature RTD Sensor 1 Close main air shutoff valve on air supply line and on system 2 Relieve fluid pressure See Pressure Relief Procedure page 17 3 Open control box cover See User Interface Control Box page 30 4 Disconnect temperature sensors 506 from FCM 218 5 Remove RTD 506 cable from cord grip 6 Replace with new temperature RTD sensor ...

Page 42: ...ainless Steel Hopper manual to service or repair the fluid inlet assembly 4 Disconnect air motor a Disconnect sensor cable air line and ground wire from air motor b Remove mounting screws 4 and washers 3 holding air motor 2 to mounting bracket See illustration in Remove Air Motor section 5 Remove pump assembly by lift ring on air motor 6 Refer to your Xtreme Displacement Pump manual to service or ...

Page 43: ...ully remove the displacement pump 66 or 67 5 Refer to your Xtreme Displacement Pump manual to service or repair the displacement pump 6 Follow steps in reverse order to reinstall displacement pump Remove Air Motor 1 Follow Pressure Relief Procedure page 17 2 Disconnect displacement pump from air motor See steps 2 and 3 under Remove Displacement Pump page 43 3 Disconnect sensor cable air line and g...

Page 44: ...scon HF or Viscon HP heater manual for wiring repair and parts information for explosion proof heaters Service and Repair 1 Follow Pressure Relief Procedure page 17 2 Disconnect fluid lines and electrical wiring from fluid heater 3 Refer to your Viscon HF heater manual to service or repair heater 4 Reconnect fluid lines and electrical wiring Replace 1 Follow steps 1 2 in Service and Repair 2 Loose...

Page 45: ...255920 Display Module Rear 288997 Front 255727 Cable CAN 15V778 Cable CAN 15V783 Pressure Transducer B Side 15M669 Pressure Transducer A Side 15M669 Temp Sensor B Side 15R347 Temp Sensor A Side 15R347 Air Motor B Side Linear Sensor 26C331 Reed Switch 24A032 Control USB MODULE Base 289899 Top 289900 Cable CAN 15V782 Air Motor A Side Linear Sensor 26C331 Reed Switch 24A032 RTD RTD ...

Page 46: ... Alternator XL Motor A XL Motor B 90 110 psi 58 76 MPa 5 8 7 6 bar Relief Valve 3 8 in O D x 4 in long Tube w Muffler 20 psi 12 MPa 1 2 bar Relief Valve 90 psi 62 MPa 6 2 bar Relief Valve 1 2 in O D x 60 in long Tube 18 psi 13 MPa 1 3 bar 94 347 344 311 604 307 40 277 209 265 279 ...

Page 47: ...CAN_RTN SHLD J6 1 2 3 4 5 BUTTON_LEFTARW BUTTON_ENTER BUTTON_FUNC3 COM BUTTONS 9 10 SHLD BUTTON_FUNC2 11 12 13 14 LED_YELLOW LED_BLUEA LED_GREEN LED_BLUEB J4 NOT USED LED_RED NOT USED NOT USED COM LEDS 1 2 3 4 5 6 7 8 9 1 2 3 4 5 P3 V CAN V CAN V CAN RTN V CAN P1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 USB Base Module 289899 CAN_L V_CAN CAN_H V_CAN_RTN SHLD...

Page 48: ...D_TOPCHGOVR COM LINEAR_SENS Linear Sensor 26C331 Reed Switch 24A032 J15 1 2 3 4 5 6 7 8 5V LINEAR_SENS COM REED SHLD REED_BTMCHGOVR LINEAR_SENS NC REED_TOPCHGOVR COM LINEAR_SENS J14 1 2 3 4 5 6 7 8 5V LINEAR_SENS COM REED SHLD REED_BTMCHGOVR UNUSED UNUSED UNUSED UNUSED J11 1 2 3 4 UNUSED UNUSED UNUSED UNUSED J25 1 2 3 4 EXCITE SHLD SENSE CONDUCTOR J11 1 2 3 4 Temp Sensor RTD 15R347 EXCITE SHLD SEN...

Page 49: ...997 Front 255727 Cable CAN Cable CAN 15V779 Pressure Transducer B Side 15M669 Pressure Transducer A Side 15M669 Temp Sensor B Side 15R347 Temp Sensor A Side 15R347 Air Motor B Side Linear Sensor 26C331 Reed Switch 24A032 Control USB MODULE Base 289899 Top 289900 Cable CAN 15V778 Air Motor A Side Linear Sensor 26C331 Reed Switch 24A032 RTD RTD Power Filter 115306 ...

Page 50: ...9W Simplified Pneumatic Schematic XM Sprayer with Wall Power XL Motor A XL Motor B 90 110 psi 58 76 MPa 5 8 7 6 bar Relief Valve 90 psi 62 MPa 6 2 bar Relief Valve 3 8 in O D x 4 in long Tube w Muffler 347 94 344 311 604 40 307 209 ...

Page 51: ...T USED LED_RED NOT USED NOT USED COM LEDS 1 2 3 4 5 6 7 8 9 1 2 3 4 5 P3 V CAN V CAN V CAN RTN V CAN P1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 USB Base Module 289899 CAN_L V_CAN CAN_H V_CAN_RTN SHLD P4 1 2 3 4 5 CAN_L V_CAN CAN_H V_CAN_RTN SHLD USB Component Module 289900 J2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 V...

Page 52: ...5 DOSE A MOTOR A Manifold LINEAR_SENS NC REED_TOPCHGOVR COM LINEAR_SENS Linear Sensor 26C331 Reed Switch 24A032 J15 1 2 3 4 5 6 7 8 5V LINEAR_SENS COM REED SHLD REED_BTMCHGOVR LINEAR_SENS NC REED_TOPCHGOVR COM LINEAR_SENS J14 1 2 3 4 5 6 7 8 5V LINEAR_SENS COM REED SHLD REED_BTMCHGOVR UNUSED UNUSED UNUSED UNUSED J11 1 2 3 4 UNUSED UNUSED UNUSED UNUSED J25 1 2 3 4 EXCITE SHLD SENSE CONDUCTOR J11 1 ...

Page 53: ...D HEATER B 1 2 3 4 FLUID HEATER A 1 2 3 4 HOPPER HEATER A 1 2 3 4 HOPPER HEATER B 1 2 3 4 HOSE HEATER BLACK BLACK GREEN WHITE WHITE HOSE HEATER FLUID HEATER B FLUID HEATER A HOPPER HEATER B HOPPER HEATER A BLACK BLACK GREEN WHITE WHITE BLACK BLACK GREEN WHITE WHITE BLACK GREEN WHITE WHITE BLACK GREEN WHITE WHITE WHITE WHITE ACCESSORIES Junction box 26C580 26C582 WL D ...

Page 54: ...2 3 4 FLUID HEATER B 1 2 3 4 FLUID HEATER A 1 2 3 4 HOPPER HEATER A 1 2 3 4 HOPPER HEATER B FLUID HEATER B FLUID HEATER A HOPPER HEATER B HOPPER HEATER A BLACK BLACK GREEN WHITE WHITE BLACK BLACK GREEN WHITE WHITE BLACK GREEN WHITE WHITE BLACK GREEN WHITE WHITE WHITE WHITE ACCESSORIES Junction box 26C899 WL D ...

Page 55: ...TER B HOPPER HEATER A BLACK BLACK GREEN WHITE WHITE BLACK BLACK GREEN WHITE WHITE BLACK GREEN WHITE WHITE BLACK GREEN WHITE WHITE WHITE WHITE ACCESSORIES Transformer SW4 SW2 SW1 SW3 1 2 3 4 FLUID HEATER B 1 2 3 4 FLUID HEATER A 1 2 3 4 HOPPER HEATER A 1 2 3 4 HOPPER HEATER B Junction box 26C904 WL D Electric Heated Hose Splice Box ...

Page 56: ... FLUID HEATER A 1 2 3 4 HOPPER HEATER A 1 2 3 4 HOPPER HEATER B 1 2 3 4 HOSE HEATER BLACK BLACK GREEN WHITE WHITE HOSE HEATER FLUID HEATER B FLUID HEATER A HOPPER HEATER B HOPPER HEATER A BLACK BLACK GREEN WHITE WHITE BLACK BLACK GREEN WHITE WHITE BLACK GREEN WHITE WHITE BLACK GREEN WHITE WHITE WHITE WHITE ACCESSORIES Junction box 26C581 26C583 WL D ...

Page 57: ... B 1 2 3 4 FLUID HEATER A 1 2 3 4 HOPPER HEATER A 1 2 3 4 HOPPER HEATER B FLUID HEATER B FLUID HEATER A HOPPER HEATER B HOPPER HEATER A BLACK BLACK GREEN WHITE WHITE BLACK BLACK GREEN WHITE WHITE BLACK GREEN WHITE WHITE BLACK GREEN WHITE WHITE WHITE WHITE ACCESSORIES Junction box 26C905 WL D Electric Heated Hose Splice Box ...

Page 58: ...R A HOPPER HEATER B HOPPER HEATER A BLACK BLACK GREEN WHITE WHITE BLACK BLACK GREEN WHITE WHITE BLACK GREEN WHITE WHITE BLACK GREEN WHITE WHITE WHITE WHITE ACCESSORIES Transformer Junction box 26C906 WL D SW4 SW2 SW1 SW3 1 2 3 4 FLUID HEATER B 1 2 3 4 FLUID HEATER A 1 2 3 4 HOPPER HEATER A 1 2 3 4 HOPPER HEATER B ...

Page 59: ...00 899 See Primary Fluid Heater Parts page 90 25 Gallon Stainless Steel Heated Hoppers Ref numbers 900 950 See 25 Gallon Hopper Parts page 91 Electric Heated Hose see your Electric Heated Hose manual 10 Gallon Stainless Steel Hoppers Ref numbers 951 999 See 10 Gallon Hopper Parts page 92 Water Heated Hose Ref numbers 1400 1499 See Water Jacketed Heated Hose page 93 Non Hazardous Location Junction ...

Page 60: ...allon Hopper Parts page 92 XM3L00 XM3A00 SYSTEM XM70 BF WP XM3_ _ _ Models page 79 XM3L10 XM3A00 SYSTEM XM70 BF WP XM3_ _ _ Models page 79 HOPPER 10 gallon ss 10 Gallon Hopper Parts page 92 XM5L00 XM5A00 SYSTEM XM50 BF R WP XM5_ _ _ Models page 80 XM5L10 XM5A00 SYSTEM XM50 BF R WP XM5_ _ _ Models page 80 HOPPER 10 gallon ss 10 Gallon Hopper Parts page 92 XM7L00 XM7A00 SYSTEM XM70 R WP XM7_ _ _ Mod...

Page 61: ...dard 240 V Primary Fluid Heater Parts page 90 HOPPER 25 gallon ss lined 240 V 25 Gallon Hopper Parts page 91 XM5M00 XM5A00 SYSTM XM50 BF R WP XM5_ _ _ Models page 80 26C580 JUNCTION BOX standard 240V Junction Box manual HEATER standard 240 V Primary Fluid Heater Parts page 90 XM5M0E XM5A00 SYSTM XM50 BF R WP XM5_ _ _ Models page 80 26C899 JUNCTION BOX standard 240V electric heat Junction Box manua...

Page 62: ...OSE heated wat 240 V H Water Jacketed Heated Hose page 93 XM7M10 XM7A00 SYSTEM XM70 BF R WP XM7_ _ _ Models page 81 26C580 JUNCTION BOX standard 240 V Junction Box manual HEATER standard 240 V Primary Fluid Heater Parts page 90 HOPPER 10 gallon ss 10 Gallon Hopper Parts page 92 XM7M1E XM7A00 SYSTEM XM70 BF R WP XM7_ _ _ Models page 81 26C899 JUNCTION BOX standard 240V electric heat Junction Box ma...

Page 63: ...rd 480 V Primary Fluid Heater Parts page 90 HOPPER 25 gallon ss lined 480 V 25 Gallon Hopper Parts page 91 XM5H00 XM5A00 SYSTEM XM50BF R WP XM5_ _ _ Models page 80 26C582 JUNCTION BOX standard 480 V Junction Box manual HEATER standard 480 V Primary Fluid Heater Parts page 90 XM5H0E XM5A00 SYSTEM XM50BF R WP XM5_ _ _ Models page 80 26C904 JUNCTION BOX standard 240V electric heat Junction Box manual...

Page 64: ...0 SYSTEM XM70 BF R WP XM7_ _ _ Models page 81 26C582 JUNCTION BOX standard 480 V Junction Box manual HEATER standard 480 V Primary Fluid Heater Parts page 90 HOPPER 10 gallon ss 10 Gallon Hopper Parts page 92 XM7H1E XM7A00 SYSTEM XM70 BF R WP XM7_ _ _ Models page 81 26C904 JUNCTION BOX standard 240V electric heat Junction Box manual HEATER standard 480 V Primary Fluid Heater Parts page 90 HOPPER 1...

Page 65: ... 93 XM5N20 XM5D00 SYSTEM XM50 BF R IS XM5_ _ _ Models page 80 HOPPER 25 gallon ss lined 240 V 25 Gallon Hopper Parts page 91 XM5N2E XM5D00 SYSTEM XM50 BF R IS XM5_ _ _ Models page 80 HOPPER 25 gallon ss lined 240 V 25 Gallon Hopper Parts page 91 HOSE heated electric 240 V H Heated Hose manual XM5N2W XM5D00 SYSTEM XM50 BF R IS XM5_ _ _ Models page 80 HOPPER 25 gallon ss lined 240 V 25 Gallon Hopper...

Page 66: ...IS XM5_ _ _ Models page 80 HOSE heated wat 240V H Water Jacketed Heated Hose page 93 XM5P10 XM5D00 SYSTEM XM50 BF R IS XM5_ _ _ Models page 80 HEATER haz ex 240 V Primary Fluid Heater Parts page 90 HOPPER 10 gallon ss 10 Gallon Hopper Parts page 92 XM5P1E XM5D00 SYSTEM XM50 BF R IS XM5_ _ _ Models page 80 HEATER haz ex 240 V Primary Fluid Heater Parts page 90 HOPPER 10 gallon ss 10 Gallon Hopper P...

Page 67: ...0 V Primary Fluid Heater Parts page 90 HOPPER 10 gallon ss 10 Gallon Hopper Parts page 92 HOSE heated wat 240V H Water Jacketed Heated Hose page 93 XM7P20 XM7D00 SYSTEM XM70 BF R IS XM7_ _ _ Models page 81 HEATER haz ex 240 V Primary Fluid Heater Parts page 90 HOPPER 25 gallon ss lined 240 V 25 Gallon Hopper Parts page 91 XM7P2E XM7D00 SYSTEM XM70 BF R IS XM7_ _ _ Models page 81 HEATER haz ex 240 ...

Page 68: ...Heated Hose manual XM5F0W XM5D00 SYSTEM XM50 BF R IS XM5_ _ _ Models page 80 HEATER haz ex 480 V Primary Fluid Heater Parts page 90 HOSE heated wat 480 V H Water Jacketed Heated Hose page 93 XM5F10 XM5D00 SYSTEM XM50 BF R IS XM5_ _ _ Models page 80 HEATER haz ex 480 V Primary Fluid Heater Parts page 90 HOPPER 10 gallon ss 10 Gallon Hopper Parts page 92 XM5F1E XM5D00 SYSTEM XM50 BF R IS XM5_ _ _ Mo...

Page 69: ...anual XM7F1W XM7D00 SYSTEM XM70 BF R IS XM7_ _ _ Models page 81 HEATER haz ex 480 V Primary Fluid Heater Parts page 90 HOPPER 10 gallon ss 10 Gallon Hopper Parts page 92 HOSE heated wat 480 V H Water Jacketed Heated Hose page 93 XM7F20 XM7D00 SYSTEM XM70 BF R IS XM7_ _ _ Models page 81 HEATER haz ex 480 V Primary Fluid Heater Parts page 90 HOPPER 25 gallon ss lined 480 V 25 Gallon Hopper Parts pag...

Page 70: ...0 V Primary Fluid Heater Parts page 90 HOPPER 25 gallon ss lined 240 V 25 Gallon Hopper Parts page 91 XM5J00 XM5D00 SYSTEM XM50 BF R IS XM5_ _ _ Models page 80 26C581 JUNCTION BOX haz ex 240 V Junction Box manual HEATER haz ex 240 V Primary Fluid Heater Parts page 90 XM5J0E XM5D00 SYSTEM XM50 BF R IS XM5_ _ _ Models page 80 26C905 JUNCTION BOX standard 240V electric heat Junction Box manual HEATER...

Page 71: ... 93 XM7J10 XM7D00 SYSTEM XM70 BF R IS XM7_ _ _ Models page 81 26C581 JUNCTION BOX haz ex 240 V Junction Box manual HEATER haz ex 240 V Primary Fluid Heater Parts page 90 HOPPER 10 gallon ss 10 Gallon Hopper Parts page 92 XM7J1E XM7D00 SYSTEM XM70 BF R IS XM7_ _ _ Models page 81 26C905 JUNCTION BOX standard 240V electric heat Junction Box manual HEATER haz ex 240 V Primary Fluid Heater Parts page 9...

Page 72: ...0 V Primary Fluid Heater Parts page 90 HOPPER 25 gallon ss lined 480 V 25 Gallon Hopper Parts page 91 XM5K00 XM5D00 SYSTEM XM50 BF R IS XM5_ _ _ Models page 80 26C583 JUNCTION BOX haz ex 480 V Junction Box manual HEATER haz EX 480 V Primary Fluid Heater Parts page 90 XM5K0E XM5D00 SYSTEM XM50 BF R IS XM5_ _ _ Models page 80 26C906 JUNCTION BOX standard 240V electric heat Junction Box manual HEATER...

Page 73: ... 93 XM7K10 XM7D00 SYSTEM XM70 BF R IS XM7_ _ _ Models page 81 26C583 JUNCTION BOX haz ex 480 V Junction Box manual HEATER haz EX 480 V Primary Fluid Heater Parts page 90 HOPPER 10 gallon ss 10 Gallon Hopper Parts page 92 XM7K1E XM7D00 SYSTEM XM70 BF R IS XM7_ _ _ Models page 81 26C906 JUNCTION BOX standard 240V electric heat Junction Box manual HEATER haz EX 480 V Primary Fluid Heater Parts page 9...

Page 74: ... 74 313289W XM Plural Component Sprayers Common Parts WL F 1 28 7 5 107 attaches to 325 8 55 31 126 58 53 54 16 64 58 60 61 59 65 62 63 94 95 XM1 XM3 Models 100 101 56 102 55 1 145 178 2c 2b 49 15 15 43 9 10 ...

Page 75: ... 15 6 89 93 16 83 84 81 82 154 87 76 52 76 86 88 85 106 126 104 105 138 107 66 or 67 129 132 133 131 134 128 3 4 2 174 XM5 XM7 Models 176 144 143 139 140 141 115 2a 32 14 18 12 14 13 7 17 19 20 11 108 80 153 100 152 103 80 ...

Page 76: ...Parts 76 313289W WL F ...

Page 77: ...ed 1 2 14 npsm 3 ft 3 54 H75002 HOSE coupled 1 2 14 npsm 2 ft 1 55 H53806 HOSE coupled 3 8 18 npsm 6 ft 2 56 15T396 TUBE recirculation 2 57 551390 SIGHTGLASS beaker graduated 10 58 H73825 HOSE coupled 3 8 18 npsm 25 ft 1 59 15B729 COUPLING 3 8 18 npsm x 3 8 18 npt 1 60 262478 HOUSING mixer 2 61 248927 KIT mixer element pack of 25 1 62 150287 COUPLING 1 4 18 npsm x 3 8 18 npt 1 63 H72510 HOSE coupl...

Page 78: ...W cap socket head 77 LABEL system 1 1 80 158491 NIPPLE 1 2 npt 2 2 81 100361 PLUG pipe 82 15R529 BLOCK fluid distribution 83 156684 UNION adapter 84 121139 O RING PTFE 85 15J594 HOUSING check valve 86 15J916 HANDLE blue 87 15R380 HANDLE green 88 255747 CARTRIDGE valve 89 262522 CARRIAGE remote mix manifold 92 113796 SCREW flanged hex head 1 1 93 111801 SCREW cap hex head 94 113498 VALVE relief 110...

Page 79: ...IPPLE 1 2 npt 2 2 81 100361 PLUG pipe 82 15R529 BLOCK fluid distribution 83 156684 UNION adapter 84 121139 O RING PTFE 85 15J594 HOUSING check valve 86 15J916 HANDLE blue 87 15R380 HANDLE green 88 255747 CARTRIDGE valve 89 262522 CARRIAGE remote mix manifold 92 113796 SCREW flanged hex head 1 1 93 111801 SCREW cap hex head 94 116643 VALVE relief 90 psi 0 63 MPa 6 3 bar 1 1 100 222200 VALVE restric...

Page 80: ...pipe 2 2 82 15R529 BLOCK fluid distribution 2 2 83 156684 UNION adapter 2 2 84 121139 O RING PTFE 2 2 85 15J594 HOUSING check valve 2 2 86 15J916 HANDLE blue 1 1 87 15R380 HANDLE green 1 1 88 255747 CARTRIDGE valve 2 2 89 262522 CARRIAGE remote mix manifold 1 1 92 113796 SCREW flanged hex head 1 1 93 111801 SCREW cap hex head 8 8 94 113498 VALVE relief 110 psi 0 76 MPa 7 6 bar 1 1 100 222200 VALVE...

Page 81: ...G pipe 2 2 82 15R529 BLOCK fluid distribution 2 2 83 156684 UNION adapter 2 2 84 121139 O RING PTFE 2 2 85 15J594 HOUSING check valve 2 2 86 15J916 HANDLE blue 1 1 87 15R380 HANDLE green 1 1 88 255747 CARTRIDGE valve 2 2 89 262522 CARRIAGE remote mix manifold 1 1 92 113796 SCREW flanged hex head 1 1 93 111801 SCREW cap hex head 8 8 94 116643 VALVE relief 90 psi 0 63 MPa 6 3 bar 1 1 100 222200 VALV...

Page 82: ...Electric Power Versions WL F 201 202 204c 204a 204d 232 232 238 221 204e 204f 210 228 229 230 240 241 243 215 224 225 217 207 235 214 209 226 208 245 203 202 223 222 220 236 204g 201 238 237 244 233 234 226 227 204b 242 242 251 243 204h 239 219c 243 226 246 ...

Page 83: ...4 SCREW machine pan head 2 214 15R379 GASKET box control 1 215 LABEL 1 216 15B056 LABEL air motor dosing valve 1 217 122000 ALARM panel mount 1 218 255920 MODULE fluid control 1 219 257088 MODULE USB assy 219a 289899 BASE 1 219b 289900 MODULE USB 1 219c 277674 DOOR module 1 220 121618 SWITCH start push button green 1 221 15R324 HARNESS USB plug bulkhead 32 in 1 222 121619 SWITCH stop push button r...

Page 84: ...nylon 5 0 ft 265 255728 ALTERNATOR module see page 89 1 266 15V778 CABLE CAN IS female B female B 20 in 1 267 15V782 CABLE CAN IS male B female B 20 in 1 268 15V783 CABLE CAN IS female A male B 39 in 1 Ref Part Description Qty 276 156971 NIPPLE short 2 x 1 4 18 npt 1 277 115243 REGULATOR air 1 4 npt 1 278 112307 ELBOW union 90 deg 1 8 npt f x 1 8 npt m carbon steel 1 279 15W017 VALVE safety regula...

Page 85: ...lock carbon steel 1 263 110637 SCREW machine pan head 3 266 15V778 CABLE CAN IS female B female B 20 in 1 270 15V747 POWER SUPPLY 24V 2 5A 60W 1 271 115306 FILTER power supply 1 272 CABLE power control box 1 272a 15X407 CABLE power US plug 1 272b 15Y685 CORD 240V 10A IEC320 1 195551 RETAINER adapter cord 1 242001 CORD set adapter Europe 1 242005 CORD set adapter Australia 1 273 100035 SCREW machin...

Page 86: ...FITTING pipe nipple 3 4 x 3 4 npt 1 317 156589 FITTING union adapter 90 deg 1 318 113911 GAUGE pressure air 1 319 BRACKET adj small air controls 2 320 115942 NUT hex flange head 4 321 18B073 LABEL control air xm skid 1 322 116513 REGULATOR air 1 323 121424 GAUGE pressure panel mount 1 5 in 1 324 100451 COUPLING 1 325 114151 FITTING elbow male swivel 2 326 116514 NUT regulator mnt 1 327 TUBE pe rnd...

Page 87: ...1 504 503 510 511 504 508 509 502 506 505 507 Ref 338 Ref 125 512 513 Ref Part Description Qty 501 255478 VALVE dosing 2 502 245143 VALVE sampling 2 503 15R381 HANDLE valve recirculation black 2 504 255747 CARTRIDGE valve check 4 505 15J594 HOUSING valve check 2 505a 121139 O RING valve PTFE 2 506 15R347 SENSOR RTD 2 507 15M669 SENSOR fluid pressure 2 507a 121399 O RING transducer pressure 2 508 2...

Page 88: ...TER ELEMENT 1 602 C19668 BUSHING 1 1 4 x 1 npt carbon 2 603 110300 FITTING elbow street pipe 3 604 158585 FITTING nipple 1 605 18B021 MANIFOLD air distribution 1 606 113163 VALVE ball vented 1 607 160022 FITTING swivel 1 608 161037 FITTING elbow swivel 3 609 127784 FITTING universal claw 1 610 127785 FITTING universal claw 1 WL D ...

Page 89: ...6 705 701 710 708 r_255278_313289a 711 Ref Part Description Qty 701 HOUSING upper and lower 1 702 GASKET stacked internal 1 703 GASKET housing 1 704 257147 TURBINE 1 705 BOARD assy 1 706 122161 FITTING air 1 707 15R337 LABEL warning 1 708 114380 SCREW cap socket head 7 709 C12508 TUBING nylon 2 ft 710 122848 FITTING air 1 711 172953 LABEL grounding 1 ...

Page 90: ...FITTING elbow 1 1 1 1 803 551387 GAUGE fluid pressure 2 2 2 2 804 24W248 HEATER hf hazardous thermostat 2 26C476 HEATER hf hazardous tstat 240V XMS 2 24P016 HEATER hf non hazardous tstat 240V XMS 2 26C475 HEATER hf non hazardous tstat 480V XMS 2 807 116171 BUSHING strain relief 2 2 808 15T967 CABLE heater fluid 3cond 12 GA 2 2 809 122032 NUT wire 4 4 810 SEALANT pipe sst 1 1 1 1 DOSING VALVE INLET...

Page 91: ...r XM 1 1 907 BRACKET attachment tank 2 2 908 125626 SCREW hex hd flanged 5 5 909 112395 SCREW cap flng hd 12 12 910 112958 NUT hex flanged 3 8 16 12 12 911 17V987 TUBE recirculation 2 2 912 112100 ADAPTER male 2 2 913 H53806 HOSE cpld 5600 psi 0 375 ID 6 ft 2 2 914 121571 FITTING elbow female swivel 1 1 4 2 2 915 C19662 BUSHING 1 1 4 x 1 npt cs 2 2 916 237522 HOSE coupled 2 2 917 16W967 FITTING sw...

Page 92: ...3864 UNION swivel 1 1 2 npt 4 953 121441 FITTING nipple hex 1 1 2 npt 2 954 121440 VALVE ball 1 1 2 npt 2 955 17E114 HOPPER weldment Xtreme 2 956 17G707 BRACKET hopper XM 2 957 256252 BRACKET hopper b mt upper painted 2 958 111192 SCREW hex hd flanged 4 959 121488 SCREW hex hd flanged 3 960 SEALANT pipe sst not shown 1 WL D ...

Page 93: ...sky 1 1401w 113161 SCREW flange hex hd 2 1401m 17N910 TUBE 34 in x 0 5 o d nylon 2 1401n 17N911 TUBE blue 0 5 o d nylon 1 1401p 126900 FITTING 1 2 tube x 3 8 nptm 1 1401z FITTING nipple quick coupling 1 1401t 17N595 WIRE ground door to enclosure 1 1402 245863 HEATER paint 1 1403 16T294 PLATE heater transfer pfp 2k 1 1404 100721 PLUG pipe 2 1405 112785 SCREW hex hd flanged 4 1406 189285 LABEL safet...

Page 94: ...esh package of 2 optional 1 Pump 67b 244895 Filter o rings PTFE package of 10 thin 2 Pump 67b 262484 Filter o rings package of 10 medium PTFE 2 Pump 67b 262483 Filter o rings PTFE package of 10 thick 2 Pump 72 15T258 Wrench Xtreme pump 1 System 75 206995 TSL quart bottle 1 System 88 255747 Cartridge circulation shut off mix manifold valves 4 6 Shut off check 88a 256239 Seal kit for cartridge valve...

Page 95: ...ainer tool push in 121410 o ring shut off u cup 1 Mix manifold 510 214037 Flush valve ball 1 4 npt m PTFE 1 Mix manifold 604a 106204 Main air filter element fits 3 4 npt air filters 1 Air controls 704 257147 Turbine cartridge fits 255728 XM or Xtreme Mix 1 Control Ref Part Description Qty Part of Assembly ...

Page 96: ...de or back of an XM sprayer See your hopper manual for more information 2 1 Drum Feed Kit 256232 One T2 pump feed kit and one Twistork agitator kit for mixing and supplying viscous materials from a with 55 gallon drum to an XM sprayer See your feed pump and agitator kit manual for more information 5 1 Drum Feed Kit 256255 One 5 1 pump feed kit and one Twistork agitator kit for mixing and supplying...

Page 97: ...Conversion Kit 256991 For converting an XM sprayer from wall power supply to intrinsically safe alternator power supply See your alternator conversion kit manual for more information Mix Manifold Kit 255684 See mix manifold manual for more information Remote Mix Manifold and Carriage Kit 256980 For converting to a remote mix manifold kit with a protective guard See your mix manifold manual for mor...

Page 98: ...Dimensions 98 313289W Dimensions XM System Dimensions without Hoppers Non Hazardous Locations WL D Ref Dimensions A 39 5 in 100 3 cm B 36 0 in 91 4 cm C 72 5 in 184 1 cm D 38 0 in 96 5 cm ...

Page 99: ...Dimensions 313289W 99 XM System Dimensions without Hoppers Hazardous Locations B D C A Ref Dimensions A 39 5 in 100 3 cm B 36 0 in 91 4 cm C 79 0 in 200 6 cm D 38 0 in 96 5 cm ...

Page 100: ...rdous Locations Hazardous Locations Ref Dimensions Non Hazardous Locations Hazardous Locations A 47 5 in 120 6 cm 47 5 in 120 6 cm B 36 0 in 91 4 cm 36 0 in 91 4 cm C 38 5 in 97 7 cm 43 5 in 110 4 cm D 38 0 in 96 5 cm 38 0 in 96 5 cm E 72 5 in 184 1 cm 79 0 in 200 6 cm ...

Page 101: ...WL D WL D Non Hazardous Locations Hazardous Locations Ref Dimensions Non Hazardous Locations Hazardous Locations A 72 5 in 184 1 cm 72 5 in 184 1 cm B 72 5 in 184 1 cm 79 0 in 200 6 cm C 50 75 in 128 9 cm 50 75 in 128 9 cm D 38 5 in 97 7 cm 43 5 in 110 5 cm ...

Page 102: ... with Hoppers WL E 72 5 in 184 2 cm 43 1 in 109 5 cm 98 6 in 255 4 cm Two 20 Gallon Hoppers Side Mounted Two 20 Gallon Hoppers Rear Mounted Top View 54 0 in 137 2 cm 49 7 in 126 2 cm 62 8 in 159 5 cm 38 5 in 975 4 cm 56 2 in 142 8 cm ti21283a ...

Page 103: ...Dimensions with Hoppers One 20 Gallon Hopper and One 7 Gallon Hopper 70 0 in 178 8 cm 33 4 in 84 8 cm 79 1 in 200 9 cm 43 1 in 109 4 cm 72 5 in 184 2 cm 33 4 in 84 8 cm 59 7 in 151 6 cm 70 0 in 178 8 cm Two 7 Gallon Hoppers ti21284a ...

Page 104: ... 57 C Storage 30 160 F 1 71 C Maximum fluid working pressure of mixed material 50 1 5200 psi 35 8 MPa 358 bar 70 1 6300 psi 43 5 MPa 435 bar Maximum fluid temperature 160 F 71 C Air supply pressure range 50 150 psi 0 35 1 0 MPa 3 5 10 3 bar Maximum pump air set pressure 50 1 100 psi 0 68 MPa 6 8 bar 70 1 90 psi 0 62 MPa 6 2 bar Maximum pump inlet fluid feed pressure 250 psi 1 7 MPa 17 bar Maximum ...

Page 105: ...er Manifold Carbon steel nickel plating carbide 302 stainless steel PTFE UHMWPE Mixer Stainless steel housing with acetal elements Spray gun Refer to spray gun manual Noise dBa Operating Pressure 70 psi 0 48 MPa 4 8 bar Sound pressure 84 8 dB A Sound power measured per ISO 3744 95 1 dB A Operating Pressure 100 psi 0 7 MPa 7 bar Sound pressure 92 2 dB A Sound power measured per ISO 3744 102 0 dB A ...

Page 106: ...n material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE Graco s sole obligation and buyer s sole remedy for any breach of warr...

Reviews: