Repair
18
3A8047B
Junction Box
Replace High Power Temperature Control
Module (HPTCM, ref. 435)
1. Turn system main power switch OFF.
2. Open junction box.
3. Unplug all connections on the HPTCM.
4. Remove screws securing HPTCM then remove
HPTCM.
5. Install HPTCM and reattach HPTCM connections.
6. Close junction box.
Replace Fluid Control Module Cube
(FCM3, ref. 408)
1. Turn system main power switch OFF.
2. Open junction box.
3. Unplug all connections on the FCM3.
4. Remove two screws securing FCM3 then remove
FCM3.
5. Use screws to install FCM3.
6. Reattach FCM3 connections.
7. Close junction box.
All electrical wiring must be done by a qualified
electrician and comply with all local codes and
regulations.
WLD
Center ground screw in the Fluid Control Module
Cube must be used to avoid serious injury due to
electric shock.