Repair
28
3A8047B
4. Set
FULL CAL
to 0.418 meters.
a. Press
+
to get to
FULL CAL
, then press
E
.
b. Press
+
until decimal point (.) appears, then
press
E
.
c. Press
+
until 4 appears, then press
E
.
d. Press
+
until 1 appears, then press
E
.
e. Press
+
until 8 appears, then press
E
.
f. Press and hold
E
until the hourglass appears,
then release.
5. Map
EMPTY TANK
.
a. Press
+
to get to
MAPPING
, then press
E
.
b. Press
E
to get to
CONFIRM DISTANCE
.
c. Press
+
until
TANK EMPTY
appears, then
press
E
.
d. Press
+
under the check mark to confirm,
END
OF SEQUENCE
will appear. Press and hold
E
until the hourglass appears, then release.
e. You are now finished. Press
+
and
-
together
until the hourglass appears, then release.
6. The transmitter display should show nothing in the
tank. Check the level display on the PFP machine
control. It should also show the tank as empty.
7. These settings can now be locked from display
control so they will not be inadvertently changed.
8. Set display to lock ON:
a. Turn display counter-clockwise to release it as
shown below (2).
b. Set the dip switch to the lock position as shown
below (3).
c. Replace display (4).
d. Replace screw on lid (5).
e. Engage cover securing clamp.