Maintenance

Cleaning

Cleaning

Cleaning the

the

the Platen

Platen

Platen

This equipment stays pressurized during the
removal of the platen from the pump. To help
prevent serious injury from moving parts while you
remove the platen for cleaning, keep fingers above
the platen. Do not attempt to grab the platen at the
edges while it is above the baseplate.

PTFE

PTFE

PTFE platen

platen

platen shown

shown

shown

When done using the pail unloader system for the
day, or when cleaning is needed so that a different
product can be pumped, perform the following:

1.

Remove the pail. See

Change Pail, page 9

.

2.

Lower the ram so that the platen is resting flat
against the baseplate.

3.

Disconnect the blowoff air hose at the blowoff
port (K).

4.

Remove the clamp at the large flange (L)
connection where the platen attaches to the
pump lower.

5.

If the platen doesn’t independently separate from
the pump, use the air controls to slightly raise
the platen off the baseplate. Then, using open
hands on opposite sides of the platen, apply
downward hand pressure to break the seal.
When the platen is loose from the pump lower
unit, continue raising the ram until the lower unit
clears the platen. Move the ram director valve
(BD) handle to neutral to stop raising the ram.

6.

Slide the platen out from under the pump lower
and lower the ram as far as possible.

7.

If more than flushing of the pump is necessary,
follow the steps in the pump manual for cleaning
the pump lower unit.

8.

Clean the platen:

a.

Refer to the drawing at left for items of the
platen assembly.

b.

Remove the cap nuts and disassemble the
platen assembly.

c.

Use a solvent compatible with the product
being unloaded and the materials of platen
construction.

d.

Reassemble the platen assembly. Tighten
the cap nuts hand tight, then torque to 40–50
in-lb in a crisscross pattern.

e.

Raise the ram and locate the platen under
the pump lower. Move fingers and tools out
of the way and slowly lower the pump into
the platen.

9.

If necessary, remove the lower unit of the pump
and disassemble for cleaning as specified in the
pump manual.

10. Attach the platen to the pump lower at the flange

(L) and re-attach the blowoff hose to the blowoff
port (K) on the platen, routing the hose through
the sanitary clamp handle eyelets.

3A5400B

11

Tel:  866-777-6060 
Fax: 866-777-6383

Springer Pumps, LLC

Website: www.springerpumps.com 

Int'l: +001 267 404 2910

Summary of Contents for SaniForce SPU.A01AAA1AA0C21

Page 1: ...ional professional use use use only only only Important Important Important Safety Safety Safety Instructions Instructions Instructions Read all warnings and instructions in this manual and in manuals...

Page 2: ...ls Models Model Model Model Certification Certification Certification Approvals Approvals Approvals SPU A01AAA1AA0C21 EN 10204 type 2 1 SPU A01AAA1AA0C31 EN 10204 type 3 1 II 2 GD Ex h IIA T4 Gb X Ex...

Page 3: ...d gasoline Do not plug or unplug power cords or turn power or light switches on or off when flammable fumes are present Use only grounded hoses Stop Stop Stop operation operation operation immediately...

Page 4: ...quest Safety Data Sheet SDS from distributor or retailer Turn off all equipment and follow the Pressure Pressure Pressure Relief Relief Relief Procedure Procedure Procedure when equipment is not in us...

Page 5: ...OTE Some combinations are not possible Please check with your local supplier Sanitary Sanitary Sanitary Pail Pail Pail Unloader Unloader Unloader Frame Frame Frame Pump Pump Pump Platen Platen Platen...

Page 6: ...flat and that the unit doesn t wobble NOTE NOTE NOTE If the unit is being located in a permanent location use the four holes in the baseplate as a guide to locate where to drill holes for mounting an...

Page 7: ...Locate upstream from all other air line accessories Air Air Air relief relief relief valve valve valve 100 100 100 psi psi psi two attached to ram integrated air controls for pump and ram air not vis...

Page 8: ...handle to the neutral center position 2 Place a full pail on the base and center it under the Platen D 3 Adjust the pail to be sure it is aligned with the platen and open the platen bleed port J NOTE...

Page 9: ...he pail to push it off of the platen c When the platen is free of the pail and the ram reaches its full height move the director valve handle BD to the neutral position 3 Remove the empty pail 4 Inspe...

Page 10: ...ng equipment Flush at the lowest pressure possible Check connectors for leaks and tighten as necessary Flush with a fluid that is compatible with the fluid being dispensed and the equipment wetted par...

Page 11: ...from the pump lower unit continue raising the ram until the lower unit clears the platen Move the ram director valve BD handle to neutral to stop raising the ram 6 Slide the platen out from under the...

Page 12: ...s A In mm B In mm C In mm D In mm E In mm F In mm G In mm 62 82 1596 42 34 1075 6 0 152 24 82 630 12 0 305 22 0 559 10 0 254 12 3A5400B Tel 866 777 6060 Fax 866 777 6383 Springer Pumps LLC Website www...

Page 13: ...ure 120 F 49 C Fluid Fluid Fluid Outlet Outlet Outlet Size Size Size Stainless Steel 1 5 in Sanitary Flange Weight Weight Weight Stainless Steel approximately 160 lb approximately 72 6 kg Wetted Wette...

Page 14: ...LAIMS DISCLAIMS ALL ALL ALL IMPLIED IMPLIED IMPLIED WARRANTIES WARRANTIES WARRANTIES OF OF OF MERCHANTABILITY MERCHANTABILITY MERCHANTABILITY AND AND AND FITNESS FITNESS FITNESS FOR FOR FOR A A A PART...

Reviews: